MEAN WELL PS-05 Series 5W Single Output Switching Power Supply
Product Information
Specifications:
- Model: PS-05 series
- Output Power: 5W
- Output Type: Single
- Input Voltage: Universal AC input / Full range
- Leakage Current: Low
MODEL | PS-05-5 | PS-05-12 | PS-05-15 | PS-05-24 | PS-05-48 | |
OUTPUT | DC VOLTAGE | 5V | 12V | 15V | 24V | 48V |
RATED CURRENT | 1A | 0.45A | 0.35A | 0.22A | 0.11A | |
CURRENT RANGE | 0 ~ 1.2A | 0 ~ 0.5A | 0 ~ 0.4A | 0 ~ 0.25A | 0 ~ 0.125A | |
RATED POWER | 5W | 5.4W | 5.25W | 5.28W | 5.28W | |
RIPPLE & NOISE (max.) Note.2 | 100mVp-p | 120mVp-p | 120mVp-p | 200mVp-p | 200mVp-p | |
VOLTAGE TOLERANCE Note.3 | ±2.0% | ±2.0% | ±2.0% | ±2.0% | ±1.0% | |
LINE REGULATION | ±1.0% | ±1.0% | ±1.0% | ±0.5% | ±0.5% | |
LOAD REGULATION | ±1.0% | ±1.0% | ±1.0% | ±0.5% | ±0.5% | |
SETUP, RISE TIME | 1000ms, 20ms | |||||
HOLD UP TIME(Typ.) | 100ms at full load | |||||
INPUT | VOLTAGE RANGE | 85 ~ 264VAC 120 ~ 370VDC | ||||
FREQUENCY RANGE | 47 ~ 63Hz | |||||
EFFICIENCY(Typ.) | 70% | 75% | 75% | 76% | 76% | |
AC CURRENT (Typ.) | 0.15A/115VAC 0.07A/230VAC | |||||
INRUSH CURRENT (Typ.) | COLD START 30A/230VAC | |||||
LEAKAGE CURRENT | <0.5mA / 240VAC | |||||
PROTECTION |
OVERLOAD |
Above 105% rated output power | ||||
Protection type : Hiccup mode, recovery automatically after fault condition is removed | ||||||
OVERVOLTAGE | 5.75 ~ 6.75V | 13.8 ~ 16.2V | 17.2 ~ 20.2V | 27.6 ~ 32.4V | 55.2 ~ 64.8V | |
OVER TEMPERATURE | Hiccup mode, recovery automatically after fault condition is removed | |||||
ENVIRONMENT | WORKING TEMP. | -10 ~ +60℃ (Refer to “Derating Curve”) | ||||
WORKING HUMIDITY | 20 ~ 90% RH non-condensing | |||||
STORAGE TEMP., HUMIDITY | -20 ~ +85℃, 10 ~ 95% RH | |||||
TEMP. COEFFICIENT | ±0.05%/℃ (0 ~ 50℃) | |||||
VIBRATION | 10 ~ 500Hz, 2G 10min./1cycle, period for 60min. each along X, Y, Z axes | |||||
SAFETY & EMC
(Note 4) |
SAFETY STANDARDS | TUV BS EN/EN62368-1,EAC TP TC 004 approved, IEC62368-1 CB approved by TUV | ||||
WITHSTAND VOLTAGE | I/P-O/P:3KVAC | |||||
ISOLATION RESISTANCE | I/P-O/P:100M Ohms / 500VDC / 25℃/ 70% RH | |||||
EMI CONDUCTION & RADIATION | Compliance to BS EN/EN55032 (CISPR32) Class B, EAC TP TC 020 | |||||
HARMONIC CURRENT | Compliance to BS EN/EN61000-3-2,-3 | |||||
EMS IMMUNITY | Compliance to BS EN/EN61000-4-2,3,4,5,6,8,11, BS EN/EN55035, light industry level, EAC TP TC 020 | |||||
OTHERS | MTBF | 6873.2K hrs min. Telcordia SR-332 (Bellcore) ; 1271.1K hrs min. MIL-HDBK-217F (25℃) | ||||
DIMENSION | 75*40*20mm (L*W*H) | |||||
PACKING | 0.05Kg; 120pcs/6.25Kg/0.56CUFT | |||||
NOTE |
Product Liability Disclaimer: For detailed information, please refer to https://www.meanwell.com/serviceDisclaimer.aspx |
Product Usage Instructions:
Features:
- Universal AC input / Full range
- Low leakage current <0.5mA
- Protections: Short circuit / Overload / Over voltage / Over temperature
- Cooling by free air convection
- 100% full load burn-in test
- Fix switching frequency at 67KHz
- Low cost
- High reliability
- 2 years warranty
GTIN CODE
MW Search: https://www.meanwell.com/serviceGTIN.aspx
Installation:
- Ensure the power supply is disconnected from the power source.
- Connect the input terminals to the AC power source following the input voltage requirements.
- Connect the output terminals to the device requiring power.
Operation:
- Once installed, switch on the power supply using the designated power switch.
- Verify that the connected device is receiving power and functioning correctly.
Mechanical SpecificationBlock Diagram
Derating Curve
Static Characteristics
Maintenance:
- Regularly check for any signs of damage or wear on the power supply unit.
- Keep the power supply unit in a well-ventilated area to prevent overheating.
Troubleshooting:
If the power supply unit fails to operate or there are issues with the output power, consult a qualified technician for assistance.
Frequently Asked Questions
Q: What should I do if the power supply gets overheated?
A: If you notice the power supply unit becoming overheated, immediately disconnect it from the power source and allow it to cool down before attempting to use it again. Ensure proper ventilation around the unit to prevent overheating.
Q: Can I use the power supply with devices that require higher output power?
A: No, it is essential to match the output power of the power supply with the requirements of the connected device to prevent damage or malfunction.
Documents / Resources
![]() |
MEAN WELL PS-05 Series 5W Single Output Switching Power Supply [pdf] Owner's Manual PS-05-5, PS-05 Series 5W Single Output Switching Power Supply, PS-05 Series, 5W Single Output Switching Power Supply, Single Output Switching Power Supply, Output Switching Power Supply, Switching Power Supply, Power Supply, Supply |
![]() |
MEAN WELL PS-05 Series 5W Single Output Switching Power Supply [pdf] Instruction Manual PS-05 Series, PS-05 Series 5W Single Output Switching Power Supply, 5W Single Output Switching Power Supply, Single Output Switching Power Supply, Switching Power Supply, Power Supply |