Owner's Manual for MEAN WELL models including: PS-05-5, PS-05 Series 5W Single Output Switching Power Supply, PS-05 Series, 5W Single Output Switching Power Supply, Single Output Switching Power Supply, Output Switching Power Supply, Switching Power Supply, Power Supply, Supply
Блок живлення що вбудовується відкритий 5W 5V PS-05-5 MeanWell за ціною від 330 грн - РКС Компоненти - РАДІОМАГ
File Info : application/pdf, 2 Pages, 112.18KB
DocumentDocument5W Single Output Switching Power Supply PS-05 series User's Manual Features : Universal AC input / Full range Low leakage current <0.5mA Protections: Short circuit / Overload / Over voltage / Over temperature Cooling by free air convection 100% full load burn-in test Fix switching frequency at 67KHz Low cost GTIN CODE MW Search: https://www.meanwell.com/serviceGTIN.aspx SPECIFICATION High reliability 2 years warranty Bauart gepruft Sicherheit egelma ge od o s be wac g www. tuv.com ID 2000000000 BS EN/EN62368-1 TPTC004 IEC62368-1 MODEL PS-05-5 PS-05-12 PS-05-15 PS-05-24 PS-05-48 DC VOLTAGE 5V 12V 15V 24V 48V RATED CURRENT 1A 0.45A 0.35A 0.22A 0.11A CURRENT RANGE 0 ~ 1.2A 0 ~ 0.5A 0 ~ 0.4A 0 ~ 0.25A 0 ~ 0.125A RATED POWER 5W 5.4W 5.25W 5.28W 5.28W OUTPUT RIPPLE & NOISE (max.) Note.2 100mVp-p VOLTAGE TOLERANCE Note.3 ±2.0% LINE REGULATION ±1.0% LOAD REGULATION ±1.0% 120mVp-p ±2.0% ±1.0% ±1.0% 120mVp-p ±2.0% ±1.0% ±1.0% 200mVp-p ±2.0% ±0.5% ±0.5% 200mVp-p ±1.0% ±0.5% ±0.5% SETUP, RISE TIME 1000ms, 20ms HOLD UP TIME(Typ.) 100ms at full load VOLTAGE RANGE 85 ~ 264VAC 120 ~ 370VDC FREQUENCY RANGE 47 ~ 63Hz INPUT EFFICIENCY(Typ.) 70% 75% 75% 76% 76% AC CURRENT (Typ.) 0.15A/115VAC 0.07A/230VAC INRUSH CURRENT (Typ.) COLD START 30A/230VAC LEAKAGE CURRENT <0.5mA / 240VAC OVERLOAD PROTECTION OVER VOLTAGE Above 105% rated output power Protection type : Hiccup mode, recovery automatically after fault condition is removed 5.75 ~ 6.75V 13.8 ~ 16.2V 17.2 ~ 20.2V 27.6 ~ 32.4V 55.2 ~ 64.8V OVER TEMPERATURE Hiccup mode, recovery automatically after fault condition is removed WORKING TEMP. -10 ~ +60 (Refer to "Derating Curve") WORKING HUMIDITY 20 ~ 90% RH non-condensing ENVIRONMENT STORAGE TEMP., HUMIDITY -20 ~ +85, 10 ~ 95% RH TEMP. COEFFICIENT ±0.05%/ (0 ~ 50) VIBRATION 10 ~ 500Hz, 2G 10min./1cycle, period for 60min. each along X, Y, Z axes SAFETY STANDARDS TUV BS EN/EN62368-1,EAC TP TC 004 approved, IEC62368-1 CB approved by TUV SAFETY & EMC (Note 4) WITHSTAND VOLTAGE ISOLATION RESISTANCE EMI CONDUCTION & RADIATION HARMONIC CURRENT I/P-O/P:3KVAC I/P-O/P:100M Ohms / 500VDC / 25/ 70% RH Compliance to BS EN/EN55032 (CISPR32) Class B, EAC TP TC 020 Compliance to BS EN/EN61000-3-2,-3 OTHERS NOTE EMS IMMUNITY Compliance to BS EN/EN61000-4-2,3,4,5,6,8,11, BS EN/EN55035, light industry level, EAC TP TC 020 MTBF 6873.2K hrs min. Telcordia SR-332 (Bellcore) ; 1271.1K hrs min. MIL-HDBK-217F (25) DIMENSION 75*40*20mm (L*W*H) PACKING 0.05Kg; 120pcs/6.25Kg/0.56CUFT 1. All parameters NOT specially mentioned are measured at 230VAC input, rated load and 25 of ambient temperature. 2. Ripple & noise are measured at 20MHz of bandwidth by using a 12" twisted pair-wire terminated with a 0.1F & 47F parallel capacitor. 3. Tolerance : includes set up tolerance, line regulation and load regulation. 4. The power supply is considered a component which will be installed into a final equipment. All the EMC tests are been executed by mounting the unit on a 360mm*360mm metal plate with 1mm of thickness. The final equipment must be re-confirmed that it still meets EMC directives. For guidance on how to perform these EMC tests, please refer to EMI testing of component power supplies. (as available on https://www.meanwell.com//Upload/PDF/EMI_statement_en.pdf ) 5. The ambient temperature derating of 3.5/1000m with fanless models and of 5/1000m with fan models for operating altitude higher than 2000m(6500ft). Product Liability DisclaimerFor detailed information, please refer to https://www.meanwell.com/serviceDisclaimer.aspx File Name:PS-05-SPEC 2024-02-23 Downloaded from Arrow.com. 5W Single Output Switching Power Supply Mechanical Specification 75 67 To chassis Grounding PS-05 series Unit:mm 32 40 1 2 3 CN2 CN1 1 2 4- 3.5 20 AC Input Connector (CN2) : Molex 5285-03 or equivalent Pin No. Assignment Mating Housing Terminal 1 FG Molex 5058 Molex 2478 2 AC/N or equivalent or equivalent 3 AC/L Block Diagram DC Output Connector (CN1) : Molex 5273-02 or equivalent Pin No. Assignment Mating Housing Terminal 1 +V Molex 5195 Molex 5194 2 -V or equivalent or equivalent : Grounding Required CN2:Pin 1 is safety ground fosc : 67KHz I/P EMI FILTER RECTIFIERS & FILTER POWER SWITCH- ING RECTIFIERS & FILTER +V -V PWM CONTROL FG DETECTION CIRCUIT Derating Curve Static Characteristics 100 80 60 40 20 -10 0 10 20 30 40 50 60 AMBIENT TEMPERATURE () (HORIZONTAL) 100 90 80 70 60 50 40 85 90 95 100 105 264 INPUT VOLTAGE (V) 60Hz File Name:PS-05-SPEC 2024-02-23 LOAD (%) LOAD (%) Downloaded from Arrow.com.