User’s Manual

MEAN-WELL-LPF-16-12-Constant-Voltage-Constant-Current-LED-Driver-fig-1 MEAN-WELL-LPF-16-12-Constant-Voltage-Constant-Current-LED-Driver-fig-2

Features

  • Constant Voltage + Constant Current mode output
  • Plastic housing with Class II design
  • Built-in active PFC function
  • Class 2 power unit
  • Standard type with IP30 level,optional IP67 with fully encapsulated
  • Typical lifetime >50000 hours
  • 5 years warranty

Applications

  • LED downlight
  • LED spotlight
  • LED decorative lighting
  • LED tunnel lighting

GTIN CODE

MW Search: https://www.meanwell.com/serviceGTIN.aspx

Description

LPF-16 series is a 16W AC/DC LED driver featuring the dual modes constant voltage and constant current output. LPF-16 operates from 90 ~ 305VAC and offers models with different rated voltage ranging between 12V and 54V. Thanks to the efficiency up to 86%, with the fanless design, the entire series is able to operate for -35°C ~ +70°C case temperature under free air convection. The entire series is suitable to work for a variety of applications at dry or damp locations and the optional models with IP67 rating is able to further work at wet locations.

Model Encodina

MEAN-WELL-LPF-16-12-Constant-Voltage-Constant-Current-LED-Driver-fig-3

SPECIFICATION

MODEL LPF-16-12 LPF-16-15   LPF-16-20   LPF-16-24   LPF-16-30   LPF-16-36   LPF-16-42   LPF-16-48   LPF-16-54  
               
 

 

 

 

OUTPUT

DC VOLTAGE 12V 15V 20V 24V 30V 36V 42V 48V 54V
CONSTANT CURRENT REGION Note.2 6.6 ~12V 8.25 ~ 15V 11 ~ 20V 13.2 ~ 24V 16.5 ~ 30V 19.8 ~ 36V 23.1 ~ 42V 26.4 ~ 48V 29.7 ~ 54V
RATED CURRENT 1.34A 1.07A 0.8A 0.67A 0.54A 0.45A 0.39A 0.34A 0.3A
RATED POWER                Note.5 16.08W 16.05W 16W 16.08W 16.2W 16.2W 16.38W 16.32W 16.2W
RIPPLE & NOISE (max.) Note.3 150mVp-p 150mVp-p 150mVp-p 150mVp-p 200mVp-p 250mVp-p 250mVp-p 250mVp-p 350mVp-p
VOLTAGE TOLERANCE Note.4 ±4.0% ±4.0% ±4.0% ±4.0% ±4.0% ±4.0% ±4.0% ±4.0% ±4.0%
LINE REGULATION ±0.5% ±0.5% ±0.5% ±0.5% ±0.5% ±0.5% ±0.5% ±0.5% ±0.5%
LOAD REGULATION ±2.0% ±1.5% ±1.0% ±0.5% ±0.5% ±0.5% ±0.5% ±0.5% ±0.5%
SETUP, RISE TIME  Note.6 1500ms, 80ms / 115VAC  500ms, 80ms / 230VAC
HOLD UP TIME (Typ.) 16ms/230VAC           16ms /115VAC
 

 

 

 

 

 

 

INPUT

VOLTAGE RANGE            Note.5 90 ~ 305VAC           127 ~ 431VDC

(Please refer to “STATIC CHARACTERISTIC” section)

FREQUENCY RANGE 47 ~ 63Hz
POWER FACTOR PF≧0.97/115VAC, PF≧0.95/230VAC, PF≧0.92/277VAC@full load

(Please refer to “POWER FACTOR (PF) CHARACTERISTIC” section)

TOTAL HARMONIC DISTORTION THD< 20%(@load≧60%/115VC,230VAC; @load≧75%/277VAC)

(Please refer to “TOTAL HARMONIC DISTORTION(THD)” section)

EFFICIENCY (Typ.) 84% 84% 86% 86% 86% 86% 86% 86% 86%
AC CURRENT 0.4A / 115VAC           0.25A / 230VAC  0.2A/277VAC
INRUSH CURRENT(Typ.) COLD START 45A(twidth=200μs measured at 50% Ipeak) at 230VAC; Per NEMA 410
MAX. No. of PSUs on 16A CIRCUIT BREAKER 14 units (circuit breaker of type B) / 24 units (circuit breaker of type C) at 230VAC
LEAKAGE CURRENT <0.75mA / 240VAC
 

 

 

PROTECTION

OVER CURRENT 95 ~ 108%
Constant current limiting, recovers automatically after fault condition is removed
SHORT CIRCUIT Hiccup mode, recovers automatically after fault condition is removed
OVER VOLTAGE 15 ~ 18V 17.5 ~ 21V 23 ~ 27V 28 ~ 35V 34 ~ 40V 41 ~ 49V 46 ~ 54V 54 ~ 63V 59 ~ 66V
Shut down and latch off o/p voltage, re-power on to recover
OVER TEMPERATURE Shut down o/p voltage, recovers automatically after temperature goes down
 

 

 

ENVIRONMENT

WORKING TEMP. Tcase=-35 ~ +70℃ (Please refer to “ OUTPUT LOAD vs TEMPERATURE” section)
MAX. CASE TEMP. Tcase=+70℃
WORKING HUMIDITY 20 ~ 95% RH non-condensing
STORAGE TEMP., HUMIDITY -40 ~ +80℃, 10 ~ 95% RH
TEMP. COEFFICIENT ±0.03%/℃ (0 ~ 50℃)
VIBRATION 10 ~ 500Hz, 2G 12min./1cycle, period for 72min. each along X, Y, Z axes
 

 

SAFETY & EMC

SAFETY STANDARDS Note.8 UL8750, CSA C22.2 No. 250.0-08; ENEC BS EN/EN61347-1, BS EN/EN61347-2-13 independent, BS EN/EN62384,J61347-1,

J61347-2-13,EAC TP TC 004,GB19510.1,GB19510.14 approved,IP67 (optional) ; Design refer to UL60950-1

WITHSTAND VOLTAGE I/P-O/P:3.75KVAC
ISOLATION RESISTANCE I/P-O/P:100M Ohms / 500VDC / 25℃/ 70% RH
EMC EMISSION  Note.8 Compliance to BS EN/EN55015,BS EN/EN61000-3-2 Class C (@load≧50%) ; BS EN/EN61000-3-3,GB/T 17743 , GB17625.1, EAC TP TC 020
EMC IMMUNITY Compliance to BS EN/EN61000-4-2,3,4,5,6,8,11; BS EN/EN61547, light industry level (surge immunity Line-Line 2KV),EAC TP TC 020
 

OTHERS

MTBF 3572.8K hrs min.     Telcordia SR-332 (Bellcore) ; 427.3K hrs min.     MIL-HDBK-217F (25℃)
DIMENSION 148*40*32mm (L*W*H)
PACKING 0.21Kg; 40pcs/9.4Kg/1.02CUFT
NOTE 1.  All parameters NOT specially mentioned are measured at 230VAC input, rated current and 25℃ of ambient temperature.

2.  Please refer to “DRIVING METHODS OF LED MODULE”.

3.  Ripple & noise are measured at 20MHz of bandwidth by using a 12″ twisted pair-wire terminated with a 0.1uf & 47uf parallel capacitor.

4.  Tolerance : includes set up tolerance, line regulation and load regulation.

5.  De-rating may be needed under low input voltages. Please refer to “STATIC CHARACTERISTIC” sections for details.

6.  Length of set up time is measured at first cold start. Turning ON/OFF the driver may lead to increase of the set up time.

7.  The driver is considered as a component that will be operated in combination with final equipment. Since EMC performance will be affected by the complete installation, the final equipment manufacturers must re-qualify EMC Directive on the complete installation again.

(as available on https://www.meanwell.com//Upload/PDF/EMI_statement_en.pdf)

8.  To fulfill requirements of the latest ErP regulation for lighting fixtures, this LED driver can only be used behind a switch without permanently connected to the mains.

9.  This series meets the typical life expectancy of >50,000 hours of operation when Tcase, particularly tc point (or TMP, per DLC), is about 70℃ or less.

10.  Please refer to the warranty statement on MEAN WELL’s website at http://www.meanwell.com

11. The ambient temperature derating of 3.5℃/1000m with fanless models and of 5℃/1000m with fan models for operating altitude higher than 2000m(6500ft).

12.  For any application note and IP water proof function installation caution, please refer our user manual before using. https://www.meanwell.com/Upload/PDF/LED_EN.pdf

※ Product Liability Disclaimer:For detailed information, please refer to https://www.meanwell.com/serviceDisclaimer.aspx

BLOCK DIAGRAM

MEAN-WELL-LPF-16-12-Constant-Voltage-Constant-Current-LED-Driver-fig-4

DRIVING METHODS OF LED MODULE

This series is able to work in either Constant Current mode (a direct driveway) or Constant Voltage mode (usually through additional DC/DC driver) to drive the LEDs.

MEAN-WELL-LPF-16-12-Constant-Voltage-Constant-Current-LED-Driver-fig-5

OUTPUT LOAD vs TEMPERATURE

MEAN-WELL-LPF-16-12-Constant-Voltage-Constant-Current-LED-Driver-fig-6

STATIC CHARACTERISTIC

MEAN-WELL-LPF-16-12-Constant-Voltage-Constant-Current-LED-Driver-fig-7

POWER FACTOR (PF) CHARACTERISTIC

MEAN-WELL-LPF-16-12-Constant-Voltage-Constant-Current-LED-Driver-fig-8

TOTAL HARMONIC DISTORTION (THD)

48V Model, Tcase at 60℃

MEAN-WELL-LPF-16-12-Constant-Voltage-Constant-Current-LED-Driver-fig-9

EFFICIENCY vs LOAD

LPF-16 series possess superior working efficiency that up to 86% can be reached in field applications.

48V Model, Tcase at 60°C

MEAN-WELL-LPF-16-12-Constant-Voltage-Constant-Current-LED-Driver-fig-10

LIFE TIME

MEAN-WELL-LPF-16-12-Constant-Voltage-Constant-Current-LED-Driver-fig-11

MECHANICAL SPECIFICATION

CASE NO.: LPF-16A Unit:mm Tolerance:±1

MEAN-WELL-LPF-16-12-Constant-Voltage-Constant-Current-LED-Driver-fig-12

Recommend Mounting Direction

MEAN-WELL-LPF-16-12-Constant-Voltage-Constant-Current-LED-Driver-fig-13

INSTALLATION MANUAL

Please refer to:http://www.meanwell.com/manual.html

Documents / Resources

MEAN WELL LPF-16-12 Constant Voltage Constant Current LED Driver [pdf] Installation Guide
LPF-16-12, LPF-16-15, LPF-16-20, LPF-16-24, LPF-16-30, LPF-16-12 Constant Voltage Constant Current LED Driver, LPF-16-12, Constant Voltage Constant Current LED Driver, Voltage Constant Current LED Driver, Constant Current LED Driver, Current LED Driver, LED Driver, Driver

References

Leave a comment

Your email address will not be published. Required fields are marked *