SUBMITTAL DATA SHEET

Air Handler Heat Pump System

Project Information

Certifications: ENERGY STAR, AHRI Certified, UL Listed, ETL Listed

Indoor Specification

ParameterValue (inch)Value (mm)
Dimension (W×D×H)17-1/2 x 21 x 23-1/2445 x 533 x 599
Package (W×D×H)20-1/2 x 26-1/8 x 26-3/8520 x 665 x 670
Net/Gross Weight59.5 / 68 lbs27 / 30.9 kg

Outdoor Specification

ParameterValue
Compressor TypeTWIN-ROTARY
Compressor ModelEKPQ420D1UMUA
RefrigerantR454B
Refrigerant Oil Charge (mL)1460
Refrigerant OilVG75
Outdoor Air Flow (Max) (CFM)3,002
Outdoor Noise Level (dBA)64
Dimension (W×D×H)38-9/16 x 16-3/8 x 38-3/8 inch (980 x 415 x 975 mm)
Package (W×D×H)45-1/16 x 19-11/16 x 42-1/2 inch (1145 x 500 x 1080 mm)
Net/Gross Weight204 / 235 lbs (92.6 / 106.7 kg)

Efficiency

RatingCoolingHeating
SEER215.8-
EER210.7-
HSPF2-4.9
COP-3.3

Performance of Cooling

ParameterValue
Rated Capacity (Btu/hr)36,000
Min/Max Capacity (Btu/hr)12,100~41,000
Moisture Removal (L/h)4.91
Standard Operating Range (°F/°C)-22~122 (-30~50)
Rated Cooling ConditionsIndoor: 80°F DB/67°F WB, Outdoor: 95°F DB/75°F WB

Performance of Heating

ParameterValue (Btu/hr)
1. @ 47°F Rated38,000
2. @ 47°F Min/Max Capacity11,500~46,000
3. @ 17°F Rated29,200
4. @ 5°F Rated: Capacity / COP36,000 / 1.9
5. @ 5°F Max: Capacity36,000
Standard Operating Range (°F/°C)-22~75 (-30~24)
1. Rated Heating ConditionsIndoor: 70°F DB/60°F WB, Outdoor: 47°F DB/43°F WB
2. Rated Heating ConditionsIndoor: 70°F DB/60°F WB, Outdoor: 17°F DB/15°F WB
3. Heating Conditions, Compressor Operating at Max. FrequencyIndoor: 70°F DB/60°F WB, Outdoor: 5°F DB/5°F WB

Electrical

ParameterValue
Indoor Power Supply24V, 60Hz, 1Ph
Indoor MCA 115V/(208/230V)/
Indoor MOP/
Outdoor Power Supply208/230, 60Hz, 1Ph
Outdoor MCA29
Outdoor MOP30
Communication WiringAWG 20-2
Compressor RLA20.5
Outdoor Fan Motor RLA2.4
Outdoor Fan Motor W/
Indoor Fan Motor RLA/
Indoor Fan Motor W/
System Power Input @ Cooling (W)3,364 (1,020 ~ 4,520)
System Power Input @ Heating (W)3,375 (800 ~ 4,540)
MCA: Min. circuit amps (A)[Not Specified]
MOCP: Max. over current protection (A)[Not Specified]
RLA: Rated load amps (A)[Not Specified]
W: Fan motor rated output (W)[Not Specified]

Piping

ParameterValue
Throttle type (Indoor)EXV
Throttle type (Outdoor)EXV
Liquid Size9.52mm (3/8in)
Gas Size19mm (3/4in)
Max. Piping Length (ft/m)246 (75)
Max. Height Difference (ft/m)98 (30)
Max. Pre-charged Length (ft)25
Refrigerant Pre-charged Amount (oz/kg)126.99 (3.6)
Additional Charge of Refrigerant ((oz/ft)/(g/m))0.7 (65)
Connection MethodFlared

Indoor Unit Dimensions

DimensionModelMVBM-24B18T3N10MVBM-24A18T3N10MVBM-36A24T4N10MVBM-36B24T4N10MVBM-36C24T4N10MVBM-60D28T6N10
inch / mminch / mminch / mminch / mminch / mminch / mm
A: Model Height18 / 45718 / 45723-5/16 / 59223-9/16 / 59924 / 61128 / 711
B: Model Width17-1/2 / 44514-1/2 / 36814-1/2 / 36817-1/2 / 44521 / 53424-1/2 / 622
C: Supply Air Opening Width16-3/16 / 41113-1/4 / 33613-1/4 / 33616-3/16 / 41119-3/4 / 50223-1/4 / 591
D: Return Air Opening Width14-15/16 / 38011-15/16 / 30311-15/16 / 30314-15/16 / 38019-1/2 / 49823-1/8 / 587
E: Condensate Drains Height1-7/16 / 381-7/16 / 381-7/16 / 381-7/16 / 382-3/16 / 552-3/16 / 55
F: Liquid Line Height11-3/8 / 29011-3/8 / 29017-15/16 / 45516-3/8 / 41717-1/2 / 44521-7/16 / 545

Outdoor Unit Dimensions & Installation Instructions

Outdoor Unit Dimensions: [Diagrams showing dimensions are described textually below]

Installation Instructions:

Clearance Requirements:

✔️ Meets all spatial requirements shown in Installation Clearance Requirements above.

Features

PDF preview unavailable. Download the PDF instead.

blueridgebng3a36ucn-36enbspecificationssheet DE474E5B-CCFC-45A5-B5E6-987A847633AA Google Sheets

Related Documents

Preview BAH5 Series Split System Heat Pump Installer's Guide
Comprehensive installer's guide for the BAH5 Series Split System Heat Pump condensing units, covering safety instructions, unit location, preparation, refrigerant line considerations, electrical connections, startup procedures, system charge adjustment, operation, troubleshooting, warranty, and checkout procedures.
Preview Air Pump Instruction Manual: Operation, Features, and Troubleshooting Guide
Detailed instruction manual for the QX series air pump, covering product operation, working principles, key features, and a troubleshooting guide for common anomalies. Ensures optimal performance and longevity for aquarium use.
Preview ECB47 Series Electric Heat Section Installation Instructions
Comprehensive installation guide for the ECB47 Series electric heat sections, detailing electrical connections, cabinet modifications, circuit breaker installation, and wiring diagrams for various air handler units. Includes safety warnings, packing lists, and technical specifications.
Preview BT301S Variable Speed Peristaltic Pump - Technical Specifications
Comprehensive technical specifications and features for the BT301S Variable Speed Plastic Peristaltic Pump, ideal for laboratory applications. Details include performance parameters, control options, communication interfaces, and available configurations.
Preview MiniVISE and MidiVISE Pump Dimensions and Technical Specifications
Detailed dimensional drawings and technical specifications for MiniVISE and MidiVISE pumps, including MiniVISE vs, MidiVISE vs, MiniVISE Flo vs, and MidiVISE Flo vs models. Provides key measurements for installation and integration.
Preview Water Pump Spare Parts Diagram and List (Model Cam-98)
Detailed spare parts list and diagram for the Cam-98 water pump system. Identifies components such as the electric pump, pressure tank, flexible hose, pressure switch, and manometer, along with their quantities and descriptions.
Preview Product Specifications: Ladder Stool and Toilet Seat Ring
Detailed specifications for a ladder stool and toilet seat ring, including material (PP+TPR), dimensions, weight, box gauge, packing, and customization options for OEM/ODM.
Preview Flowclear Pool Pump and Filter Connection Guide
Step-by-step instructions for assembling Flowclear pool pump and filter components and connecting them to inflatable pools, covering component assembly and hose connections.