I. SAFETY

Before using the device for the first time, the user should read the following regulations carefully. Not obeying the rules included in this manual may lead to personal injuries or controller damage. The user's manual should be stored in a safe place for further reference.

In order to avoid accidents and errors, it should be ensured that every person using the device has familiarized themselves with the principle of operation as well as security functions of the controller. If the device is to be sold or put in a different place, make sure that the user's manual is stored with the device so that any potential user has access to essential information about the device.

The manufacturer does not accept responsibility for any injuries or damage resulting from negligence; therefore, users are obliged to take the necessary safety measures listed in this manual to protect their lives and property.

WARNING

  • ⚠️ A live electrical device! Make sure the regulator is disconnected from the mains before performing any activities involving the power supply (plugging cables, installing the device etc.).
  • The device should be installed by a qualified electrician.
  • The device should not be operated by children.

WARNING

  • The device may be damaged if struck by a lightning. Make sure the plug is disconnected from the power supply during a thunderstorm.
  • Any use other than specified by the manufacturer is forbidden.
  • The device should be periodically checked.

Changes in the merchandise described in the manual may have been introduced subsequent to its completion on 22.08.2023. The manufacturer retains the right to introduce changes to the structure or colours. The illustrations may include additional equipment. Print technology may result in differences in the colours shown.

We are committed to protecting the environment. Manufacturing electronic devices imposes an obligation of providing for environmentally safe disposal of used electronic components and devices. Hence, we have been entered into a register kept by the Inspection for Environmental Protection. The crossed-out bin symbol on a product means that the product may not be disposed of to household waste containers. Recycling of waste helps to protect the environment. The user is obliged to transfer their used equipment to a collection point where all electric and electronic components will be recycled.

II. DEVICE DESCRIPTION

The EU-T-4.1N/EU-T-4.2N room regulator is intended for controlling the heating device (e.g. gas, oil or electric boiler or the boiler controller). Its main task is to maintain the pre-set temperature in the flat by sending a signal to the heating/cooling device (contact opening) when the desired temperature is reached.

Advanced software enables the regulator to fulfil a wide range of functions:

  • Maintaining the pre-set room temperature
  • Manual mode
  • Day/night program
  • Weekly control
  • Optimum Start
  • Heating/cooling
  • Button lock
  • Automatic manual mode

Controller equipment:

  • Front panel made of glass
  • Built-in temperature sensor
  • Batteries

Regulator versions:

  • EU-T-4.1N - wired version
  • EU-T-4.2N – wireless version (regulator + receiver EU-MW-3)

III. HOW TO INSTALL THE CONTROLLER

The controller should be installed by a qualified electrician.

The EU-T-4.1N/EU-T-4.2N regulator may be put in any place (1) or used as a wall-mountable panel (2).

1) The regulator may be supported with a stand which should be attached to the back cover.

2) In order to hang the regulator on the wall, remove the stand carefully.

To insert batteries, remove the back cover.

1. EU-T-4.1N CONNECTION DIAGRAM

The room regulator should be connected to the heating device or the CH boiler controller with the use of a two-core cable. The diagram below illustrates how to connect the devices.

WARNING: If pump manufacturer requires an external main switch, power supply fuse or additional residual current device selective for distorted currents, it is recommended not to connect pumps directly to pump control outputs. To avoid damaging the device, an additional safety circuit must be used between the regulator and the pump. The manufacturer recommends the ZP-01 pump adapter, which must be purchased separately.

2. EU-T-4.2N CONNECTION DIAGRAM

In the case of wireless connection, use the above diagrams - a two-core communication cable should be connected to appropriate ports in the receiver.

IV. EU-MW-3 RECEIVER

The EU-T-4.2N regulator communicates with the heating device (or the CH boiler controller) by means of a radio signal sent to the EU-MW-3 receiver. Such a receiver is connected to the heating device (or the CH boiler controller) by means of a two-core cable, and communicates with the room regulator using a radio signal.

The receiver has three control lights:

  • Red control light 1 – it signals data reception;
  • Red control light 2 – indicates receiver operation;
  • Red control light 3 – goes on when the room temperature fails to reach the pre-set value – the heating device is switched on.

NOTE: In case of no communication (e.g. due to discharged battery), the receiver automatically disables the heating device after 15 minutes.

Registration of the EU-MW-3 receiver:

  1. Press the registration button on the EU-MW-3 receiver.
  2. In order to register the relays, select the "Reg" function in the Menu of the regulator and hold the [Menu Button] or press one of the [Up/Down Buttons]. The message "Scs" means that the registration was successful, while a registration error is signalled with the message "Err". In both cases, the registration can be continued by pressing any button (except [Exit Button]).

The number of registered relays is displayed on the screen. If the regulator has 6 registered relays (maximum number), it is possible to unregister them and the "Del" message is displayed. Using one of the [Up/Down Buttons], select the appropriate option "yes" or "no" depending on whether you want to unregister the relay or not.

V. FIRST START-UP

In order for the regulator to operate correctly, follow these steps when starting the device for the first time:

  1. Insert the batteries - to do this, remove the back cover.
  2. Connect the two-core cable to appropriate sockets in the regulator or the receiver.

VI. HOW TO USE THE REGULATOR

1. PRINCIPLE OF OPERATION

The EU-T-4.1N/EU-T-4.2N room regulator is designed to maintain the pre-set room temperature by sending a signal to the heating device (contact opening) when the pre-set room temperature has been reached. After receiving such a signal, the heating device is disabled (if it is connected to a CH boiler controller, the CH boiler switches to sustain mode after receiving the signal).

2. OPERATION MODES

The room regulator may operate in one of the following operation modes:

  • Day/night mode

    In this mode, the pre-set temperature value depends on the current time of the day. The user may set different temperature values for the daytime and nighttime (comfort temperature and economical temperature) as well as define the exact time of entering day mode and night mode.

    In order to activate this mode, press one of the [Up/Down Buttons] until the [Day/Night Mode Icon] appears on the main screen.

  • Weekly control

    This mode enables the user to define the time when the pre-set comfort temperature and the pre-set economical temperature will apply. The user may set 9 different programs divided into three groups:

    • PROGRAMS 1-3: daily temperature values are set for all days of the week;
    • PROGRAMS 4-6: daily temperature values are set separately for the weekdays (Monday-Friday) and for the weekend (Saturday-Sunday);
    • PROGRAMS 7-9: daily temperature values are set for each day of the week separately.

    In order to activate this mode, press one of the [Up/Down Buttons] until a [Weekly Control Icon] appears on the main screen.

  • Manual mode

    In this mode, the pre-set temperature is adjusted manually from the main screen view with the use of plus/minus buttons ([Plus Button]/[Minus Button]). Manual mode is activated automatically when one of these buttons is pressed. Once the manual mode is activated, the previous operation mode enters sleep mode until the next pre-programmed temperature change. Manual mode may be deactivated by pressing one of these buttons: [Up Button] or [Down Button].

    When Day/night mode is active, the user changes the pre-set temperature by pressing [Plus Button]/[Minus Button], which automatically activates manual mode. The controller returns to Day/night mode when daytime changes into nighttime (or the other way round) or when the user presses one of the [Up/Down Buttons].

    When Weekly control mode is active, the user changes the pre-set temperature by pressing [Plus Button]/[Minus Button], which automatically activates manual mode. The controller returns to Weekly control mode when, according to the weekly schedule, daytime changes into nighttime (or the other way round) or when the user presses one of the [Up/Down Buttons].

3. MAIN SCREEN VIEW AND DESCRIPTION

The user operates the device using buttons. While one parameter is being edited, the remaining icons are not displayed.

Display Elements:

  • 1. Display: Shows current settings and status.
  • 2. [Weekly Control Button]: In the main screen view, use this button to activate weekly control mode. In the controller menu, use this button to switch between functions.
  • 3. [Minus Button] (-): In the main screen view, press this button to switch to manual mode and decrease the pre-set temperature value. In the controller menu, use this button to change parameter settings, enter the service code etc.
  • 4. [Menu Button]: Hold this button to enter the controller menu. While editing parameters, press and hold this button to confirm the changes and return to the main screen view.
  • 5. [Plus Button] (+): In the main screen view, press this button to switch to manual mode and increase the pre-set temperature value. In the controller menu, use this button to change parameter settings, enter the service code etc.
  • 6. [Day/Night Mode Button]: In the main screen view, use this button to activate day/night mode. In the controller menu, use this button to switch between functions.

Main Screen Icons Explained:

  • 1. Day of the week: Displays the current day.
  • 2. Economical Temperature Icon: An icon informing about current economical temperature (resulting from weekly control or day/night mode settings).
  • 3. Comfort Temperature Icon: An icon informing about current comfort temperature (resulting from weekly control or day/night mode settings).
  • 4. Pre-set room temperature: Displays the target temperature.
  • 5. Time: Displays the current time.
  • 6. Battery Level Icon: Shows the battery status.
  • 7. Heating/Cooling Icon: An icon informing about room cooling/heating. The animation differs depending on the selected operation mode:
    • Heating mode – the icon flashes when the pre-set temperature has not been reached; it is steady when the pre-set temperature has been reached.
    • Cooling mode – the icon rotates when the temperature is above the pre-set value; it is steady when the pre-set temperature has been reached.
  • 8. Current operation mode: Indicates the active mode (Weekly, Manual, Day/night).
  • 9. Current room temperature: Displays the actual room temperature.
  • 10. Parameter Icons: Icons representing various settings and functions.

Parameter Icons:

IconFunctionIconFunction
[Clock Settings Icon]Clock settings[Weekly Control Settings Icon]Weekly control settings
[Day From Icon]Day from...[Comfort Temperature Icon]Comfort temperature
[Night From Icon]Night from...[Economical Temperature Icon]Economical temperature
[Optimum Start Icon]Optimum start / heating/cooling mode selection (in service menu)[Hysteresis Icon]Hysteresis
[Service Menu Icon]Service menu[Temperature Sensor Calibration Icon]Temperature sensor calibration

4. CONTROLLER FUNCTIONS

The user navigates the menu structure using all the buttons ([Up Button], [Down Button], [Plus Button], [Minus Button]). In order to edit particular parameters, press and hold [Menu Button]. Next, press [Down Button] to view the controller functions – the edited parameter is flashing, whereas the remaining parameters are not displayed. Use [Plus Button] and [Minus Button] to change the parameter settings. Press [Down Button] to confirm the changes and move on to edit the next parameter or press [Up Button] to confirm the changes and return to the previous parameter or press and hold [Menu Button] to confirm and return to the main screen view - apart from editing weekly control settings.

4.1. MAIN MENU

  • Day of the week
  • Clock
  • Day from...
  • Night from...
  • Button lock
  • Optimum start
  • Automatic manual mode
  • Weekly program
  • Pre-set comfort temperature
  • Pre-set economical temperature
  • Pre-set temperature hysteresis
  • Temperature sensor calibration
  • Registration (EU-T-4.2n)
  • Service menu

4.2. DAY OF THE WEEK

After entering the main menu, all icons which are not connected with the parameter being edited are not displayed. The first parameter is day of the week. Press [Plus Button] or [Minus Button] until the current day of the week appears on the screen. Press [Down Button] to confirm and move on to the next parameter or press and hold [Menu Button] to confirm and return to the main screen view.

4.3. CLOCK

In order to set the current time, enter the menu and press [Up Button] or [Down Button] until the time setting screen appears on the screen. By pressing [Plus Button] or [Minus Button], set the hour and minutes. Press [Down Button] to confirm. Press [Down Button] to confirm and move on to the next parameter or press and hold [Menu Button] to confirm and return to the main screen view.

4.4. DAY FROM...

This function enables the user to define the exact time of entering the day mode. When Day/night mode is active, comfort temperature applies at daytime. To configure this parameter, press [Up Button] or [Down Button] until the "Day from..." setting screen appears. By pressing [Plus Button] or [Minus Button], set the hour and minute of day mode activation. Press [Down Button] to confirm and move on to the next parameter or press and hold [Menu Button] to confirm and return to the main screen view.

4.5. NIGHT FROM...

This function enables the user to define the exact time of entering the night mode. When Day/night mode is active, economical temperature applies at nighttime. To configure this parameter, press [Up Button] or [Down Button] until the "Night from..." setting screen appears. By pressing [Plus Button] or [Minus Button], set the hour and minute of night mode activation. Press [Down Button] to confirm and move on to the next parameter or press and hold [Menu Button] to confirm and return to the main screen view.

4.6. BUTTON LOCK

In order to activate the button lock, press [Menu Button] until a [Padlock Icon] appears. Use one of the [Up Button] or [Down Button] to select ON. In order to unlock the buttons, press and hold the [Up Button] and [Down Button] at the same time, select the button lock function and select OFF.

4.7. OPTIMUM START

Optimum start is an intelligent system controlling the heating/cooling process. It involves constant monitoring of the heating/cooling system efficiency and using the information to activate the heating/cooling process in advance in order to reach the pre-set temperatures.

The system requires no user intervention. It precisely reacts to any changes that affect the efficiency of the heating system. If, for example, some changes have been introduced to the heating system and the house heats up faster than before, the Optimum start system will recognize the changes at the next pre-programmed temperature change (from comfort to economical) and in the next cycle, the heating system activation will be adequately delayed, reducing the time needed to reach the desired temperature.

Activating this function means that at the time of pre-programmed change of the pre-set temperature from comfort to economical or the other way round, the current room temperature is close to the desired value.

In order to configure this parameter, press one of the [Up/Down Buttons] until the Optimum start setting panel appears on the screen. Use [Plus Button] or [Minus Button] to activate or deactivate Optimum start function (ON/OFF). Press [Down Button] to confirm and move on to edit the next parameter or press and hold [Menu Button] to confirm and return to the main screen view.

4.8. AUTOMATIC MANUAL MODE

This function enables manual mode control. If this function is active (ON), the manual mode is disabled automatically when a pre-programmed change resulting from the previous operation mode is introduced. If the function is disabled (OFF), the manual mode remains active regardless of the pre-programmed changes.

4.9. WEEKLY PROGRAM

This function is used to change the current weekly control program and edit the weekly programs.

  • How to change weekly program number

    When weekly control is enabled, the current program is activated. In order to select the current program number, enter the menu and press one of the [Up/Down Buttons] or [Menu Button] until the weekly program setting screen opens up. By pressing and holding the [Menu Button], the user opens up the program selection screen. Each time the user holds the [Menu Button], the program number changes. When the desired number appears on the screen, press [Menu Button] – the controller returns to the main screen view and the selected program number is set.

  • How to configure particular weekly programs

    Weekly program allows the user to define the time when comfort temperature and economical temperature will apply. Depending on the program number, the user may set daily temperature values for all days of the week (programs 1-3), for weekdays and the weekend separately (programs 4-6), and for each day of the week separately (programs 7-9).

    STEP 1 - CHOOSE THE PROGRAM TO BE EDITED

    By pressing and holding the [Menu Button], the user opens up the program editing screen. Each time the user presses the [Menu Button], the program number changes. When the desired number appears on the screen, the user may start editing its parameters.

    STEP 2 - SELECT DAYS OF THE WEEK

    If the user wants to edit programs 1-3, there is no possibility of selecting particular days of the week as the setting applies to each day.

    If the user wants to edit programs 4-6, it is possible to edit the settings for weekdays and the weekend separately. Press [Up Button] or [Down Button] briefly in order to select.

    If the user wants to edit programs 7-9, it is possible to edit the settings for each day separately. Press [Up Button] or [Down Button] briefly in order to select a day.

    STEP 3 - ASSIGNING COMFORT OR ECONOMICAL TEMPERATURE TO PARTICULAR HOURS

    An hour which is being edited is displayed on the controller screen. In order to assign comfort temperature, press the [Plus Button] (+). In order to select economical temperature, press the [Minus Button] (-).

    The parameters of the weekly program are displayed at the bottom of the screen: hours to which comfort temperature has been assigned are displayed, whereas hours to which economical temperature has been assigned are not displayed.

4.10. PRE-SET COMFORT TEMPERATURE

Pre-set comfort temperature is used in weekly control mode and day/night mode. Press one of the [Up/Down Buttons] until the comfort temperature change screen appears on the screen. Press [Plus Button] or [Minus Button] to set the desired temperature. Press [Down Button] to confirm and move on to the next parameter or press and hold [Menu Button] to confirm and return to the main screen view.

4.11. PRE-SET ECONOMICAL TEMPERATURE

Pre-set economical temperature is used in weekly control mode and day/night mode. Press one of the [Up/Down Buttons] until the economical temperature change screen appears on the screen. Press [Plus Button] or [Minus Button] to set the desired temperature. Press [Down Button] to confirm and move on to the next parameter or press and hold [Menu Button] to confirm and return to the main screen view.

4.12. PRE-SET TEMPERATURE HYSTERESIS

Room temperature hysteresis defines the tolerance of the pre-set temperature at which cooling or heating is activated (within the range of 0.2 ÷ 4°C).

In order to set the hysteresis, press one of the [Up/Down Buttons] until the hysteresis settings appear on the screen. Use [Plus Button] or [Minus Button] to set the desired hysteresis value. Press [Down Button] to confirm and move on to the next parameter or press and hold [Menu Button] to confirm and return to the main screen view.

Example: Pre-set temperature: 23°C, Hysteresis: 1°C. The room regulator reports that the temperature is too low only when the room temperature drops to 22°C.

4.13. TEMPERATURE SENSOR CALIBRATION

This is performed when mounting the regulator or after it has been used for a long time, if the room temperature measured by the internal sensor differs from the actual temperature. Calibration setting range is from -10°C to +10°C with an accuracy of 0.1°C.

Press one of the [Up/Down Buttons] until the sensor calibration panel appears on the screen. Use [Plus Button] and [Minus Button] to define correction. Press [Down Button] to confirm and move on to edit the next parameter or press and hold [Menu Button] to confirm and return to the main screen view.

4.14. REGISTRATION

The description of the functions can be found in chapter IV. Wireless controller receiver.

4.15. SERVICE MENU

Certain functions in the controller service menu are secured with a code. In order to adjust their parameters, press one of the [Up/Down Buttons] until Service menu settings appear on the screen.

To view the service menu, it is necessary to enter the code – 215. Use [Plus Button] or [Minus Button] to select the first digit (2) and press [Menu Button] to confirm. Follow the same steps selecting the remaining two digits. Press the [Down Button] to confirm the code.

  • Heating/Cooling Mode: This function enables the user to select the room regulator operation mode: COOL - controlling the cooling system, HEAT - controlling the heating system. Press [Plus Button] or [Minus Button] to select the desired type of system. Press [Down Button] to confirm and move on to edit another parameter in the service menu or press [Menu Button] to confirm and return to the main screen view.
  • How to edit the minimum (T1) and maximum (T2) pre-set temperature: This function enables the user to set the minimum (T1) and the maximum (T2) pre-set room temperature. Select this option - the parameter starts flashing. Use the [Plus Button]/[Minus Button] to set the temperature. To confirm, press the [Menu Button] (confirm and go on to edit the next parameter) or press [Exit Button] to confirm and return to the main screen view.
  • Optimum Start calibration: Optimum start calibration starts when the controller detects the heating need in order to reach the pre-set temperature, with the Optimum start function turned on.
  • DEF factory settings: This function enables the user to restore factory settings. In order to do it, select "Def" function and press [Menu Button] to confirm. Next, use the [Plus Button]/[Minus Button] to select YES and confirm by pressing [Menu Button].

VII. TECHNICAL DATA

EU-T-4.1NEU-T-4.2N
Power supply2xAA, 1.5V batteries2xAA, 1.5V batteries
Room temp. adjustment range5°C ÷ 35°C5°C ÷ 35°C
Potential-free cont. nom. out. load230V AC / 0.5A (AC1) *
24V DC / 0.5A (DC1) **
± 0.5
Measurement error± 0.5868MHz
Operation frequency-
EU-MW-3 (EU-T-4.2N)
Power supply230V ± 10% / 50Hz
Operation temperature5°C ÷ 50°C
Maximum power consumption<1W
Potential-free cont. nom. out. load230V AC / 0.5A (AC1) *
24V DC / 0.5A (DC1) **
Operation frequency868MHz
Max. transmission power25mW

* AC1 load category: single-phase, resistive or slightly inductive AC load.
** DC1 load category: direct current, resistive or slightly inductive load.

Declarations of Conformity

EU declaration of conformity

Hereby, TECH STEROWNIKI II Sp. z o.o., headquartered in Wieprz Biała Droga 31, 34-122 Wieprz, declares that the EU-T-4.1N is compliant with Directive 2014/35/EU of the European Parliament and of the Council of 26 February 2014 on the harmonisation of the laws of Member States relating to the making available on the market of electrical equipment designed for use within certain voltage limits (EU OJ L 96, of 29.03.2014, p. 357), Directive 2014/30/EU of the European Parliament and of the Council of 26 February 2014 on the harmonisation of the laws of Member States relating to electromagnetic compatibility (EU OJ L 96 of 29.03.2014, p.79), Directive 2009/125/EC establishing a framework for the setting of ecodesign requirements for energy-related products, and the regulation by the Ministry OF ENTREPRENEURSHIP AND TECHNOLOGY of 24 June 2019 amending the regulation concerning the essential requirements as regards the restriction of the use of certain hazardous substances in electrical and electronic equipment, implementing provisions of Directive (EU) 2017/2102 of the European Parliament and of the Council of 15 November 2017 amending Directive 2011/65/EU on the restriction of the use of certain hazardous substances in electrical and electronic equipment (OJ L 305, 21.11.2017, p. 8).

For compliance assessment, harmonized standards were used: PN-EN IEC 60730-2-9:2019-06, PN-EN 60730-1:2016-10, EN IEC 63000:2018 RoHS.

UE declaration of conformity

Hereby, TECH STEROWNIKI II Sp. z o.o., headquartered in Wieprz Biała Droga 31, 34-122 Wieprz, declares that the EU-T-4.2N is compliant with Directive 2014/53/EU of the European Parliament and of the Council of 16 April 2014 on the harmonisation of the laws of the Member States relating to the making available on the market of radio equipment, Directive 2009/125/EC establishing a framework for the setting of ecodesign requirements for energy-related products, and the regulation by the Ministry OF ENTREPRENEURSHIP AND TECHNOLOGY of 24 June 2019 amending the regulation concerning the essential requirements as regards the restriction of the use of certain hazardous substances in electrical and electronic equipment, implementing provisions of Directive (EU) 2017/2102 of the European Parliament and of the Council of 15 November 2017 amending Directive 2011/65/EU on the restriction of the use of certain hazardous substances in electrical and electronic equipment (OJ L 305, 21.11.2017, p. 8).

For compliance assessment, harmonized standards were used: PN-EN IEC 60730-2-9 :2019-06 art. 3.1a Safety of use, PN-EN 62479:2011 art. 3.1 a Safety of use, ETSI EN 301 489-1 V2.2.3 (2019-11) art.3.1b Electromagnetic compatibility, ETSI EN 301 489-3 V2.1.1:2019-03 art.3.1 b Electromagnetic compatibility, ETSI EN 300 220-2 V3.2.1 (2018-06) art.3.2 Effective and coherent use of radio spectrum, ETSI EN 300 220-1 V3.1.1 (2017-02) art.3.2 Effective and coherent use of radio spectrum, EN IEC 63000:2018 RoHS.

Wieprz, 22.08.2023

Models: EU-T-4.1n Wireless Thermostat, EU-T-4.1n, Wireless Thermostat, Thermostat

File Info : application/pdf, 20 Pages, 1.41MB

PDF preview unavailable. Download the PDF instead.

en eu-t-4n 22.08.2023 Microsoft Word dla Microsoft 365

Related Documents

Preview TECH Controllers EU-T-4.1/EU-T-4.2 User Manual
Comprehensive user manual for TECH Controllers EU-T-4.1 and EU-T-4.2 digital room thermostats, detailing installation, operation, functions, safety, and technical specifications.
Preview TECH CONTROLLERS EU-T-3.2 User Manual
This user manual provides comprehensive guidance for the TECH CONTROLLERS EU-T-3.2 room regulator, detailing its installation, operation modes, key features like Day/Night and Manual modes, sensor calibration, and technical specifications for efficient home heating management.
Preview TECH CONTROLLERS EU-293v2 User Manual: Installation, Operation, and Technical Data
Comprehensive user manual for the TECH CONTROLLERS EU-293v2 room regulator. Covers installation, operation modes, controller functions, technical specifications, and safety guidelines.
Preview TECH CONTROLLERS EU-293v3 User Manual: Installation and Operation Guide
Comprehensive user manual for the TECH CONTROLLERS EU-293v3 room regulator. Learn about installation, operation modes, settings, and technical specifications for efficient heating and cooling control.
Preview TECH EU-L-4X WiFi User Manual - Smart Heating and Cooling Controller
This user manual provides detailed information on the TECH EU-L-4X WiFi controller, covering system description, installation, operation modes, zone management, advanced functions, troubleshooting, and technical specifications for efficient home climate control.
Preview TECH CONTROLLERS EU-T-3.2 User Manual
Comprehensive user manual for the TECH CONTROLLERS EU-T-3.2 room regulator. This guide provides detailed information on safety, device description, installation, operation modes, controller functions, calibration, registration, technical data, and EU declaration of conformity for efficient heating control.
Preview TECH CONTROLLERS EU-M-12t User Manual: Installation and Operation Guide
Comprehensive user manual for the TECH CONTROLLERS EU-M-12t control panel, detailing installation, system setup, operation modes, zone management, settings, and technical specifications for efficient heating control.
Preview TECH CONTROLLERS EU-WiFi X User Manual: Installation, Setup, and Operation Guide
Comprehensive user manual for the TECH CONTROLLERS EU-WiFi X module. Covers installation, internet connection, emodul.eu app control, zone management, software updates, and technical specifications. Learn how to optimize your heating system.