Ledvion
LED HIGH BAY
5 YEARS OF WARRANTY
Address: Habraken 1205, 5507 TB Veldhoven, The Netherlands
Website: www.ledvion.com
Models: LV70001, LV70002, LV70003, LV70004, LV70005, LV70006, LV70007, LV70008, LV70009, LV70057, LV70058, LV70059, LV70010, LV70011, LV70012, LV70013, LV70014, LV70015 & LV70016
General Installation Instructions
Attention: Installation should only be performed by individuals with electro-technical knowledge and experience. These products are not suitable for installation in locations near the sea or in environments with a corrosive atmosphere.
- Ensure the main power source is turned off. [Power Off Symbol]
- Connect the device to the mains supply using the terminal block*.
- Verify that the cables are securely connected to the terminals on the device.
- After installation is complete, activate the power source and test the function.
*Terminal block is not included.
Technical Data
Model | Voltage | Power/Wattage | Useful Lumen | Lumen | Dimensions | Beam Angle | Color Temperature |
---|---|---|---|---|---|---|---|
LV70001 | AC220-240V | 100W | 13700LM | 17500LM | 169*126* dia 205 mm | 120° | 3000K |
LV70002 | AC220-240V | 100W | 13700LM | 17500LM | 169*126* dia 205 mm | 120° | 4000K |
LV70003 | AC220-240V | 100W | 13700LM | 17500LM | 169*126* dia 205 mm | 120° | 6500K |
LV70004 | AC220-240V | 150W | 20500LM | 26500LM | 171*128* dia 235 mm | 120° | 4000K |
LV70005 | AC220-240V | 150W | 20500LM | 26500LM | 171*128* dia 235 mm | 120° | 6500K |
LV70006 | AC220-240V | 200W | 27300LM | 35000LM | 186.2*143.2* dia 265 mm | 120° | 4000K |
LV70007 | AC220-240V | 200W | 27300LM | 35000LM | 186.2*143.2* dia 265 mm | 120° | 6500K |
LV70008 | AC220-240V | 240W | 32700LM | 42000LM | 186.2*143.2* dia 265 mm | 120° | 4000K |
LV70009 | AC220-240V | 240W | 32700LM | 42000LM | 186.2*143.2* dia 265 mm | 120° | 6500K |
LV70057* | AC220-240V | 150W | 20500LM | 26500LM | 171*128* dia 235 mm | 120° | 3000K |
LV70058* | AC220-240V | 200W | 27300LM | 35000LM | 186.2*143.2* dia 265 mm | 120° | 3000K |
LV70059* | AC220-240V | 240W | 32700LM | 42000LM | 186.2*143.2* dia 265 mm | 120° | 3000K |
*These products are not GS Certified. |
Accessories
High Bay Reflectors
SKU | Compatible for | Body type |
---|---|---|
LV70010 | 100W | Aluminium |
LV70011 | 150W | Aluminium |
LV70012 | 150W | Aluminium |
LV70013 | 200W/240W | Aluminium |
LV70014 | 200W/240W | Aluminium |
High Bay Adjustable Bracket
SKU | Compatible for | Body type |
---|---|---|
LV70014 | 100-150-200-240W | Steel |
High Bay Sensor
SKU | Compatible for | Volt |
---|---|---|
LV70015 | 100-150-200-240W | 100-277V |
High Bay Sensor Remote Control
SKU | Compatible for |
---|---|
LV70016 | 100-150-200-240W |
Installation Procedures
Manual Installation Steps
Follow these steps for manual installation:
- Step 1: Ensure power is OFF. [Power Off Symbol]
- Step 2: Connect wiring as per diagram. [Wire connection diagram description: Show connection of wires to terminals.]
- Step 3: Hang the fixture securely. [Hanging fixture diagram description: Fixture suspended from ceiling.]
- Step 4: Secure the fixture to the mounting surface. [Securing fixture diagram description: Fixture being attached to the ceiling.]
- Step 5: Connect power supply wires to the fixture. [Power connection diagram description: Mains power connected to the fixture terminals.]
- Step 6: Perform final checks. [Final check diagram description: Visual inspection of connections.]
- Step 7: Turn power ON. [Power On Symbol]
Important Notes:
- The installation base must be able to support 10 times the weight of the product.
- Maintain a minimum distance of 1 meter from lighted objects.
- Replace any cracked protective shield before installation.
The product is certified by DEKRA for safety. [DEKRA Logo Description]
Dimmer Installation
For 100W - 150W - 200W Models:
Connect wires:
- DIM+ (Brown wire)
- DIM- (Blue wire)
- AC/L (Brown wire)
- AC/N (Blue wire)
- PE (Green/Yellow wire)
Use 2x 0.35mm² stranded wires for DIM connections and 3x 1.04mm² stranded wires for AC/N, AC/L, PE connections.
For 240W Models:
Connect wires:
- DIM+ (Purple wire)
- DIM-/12V- (Pink wire)
- 12V+ (Black/White wire)
- AC/L (Brown wire)
- AC/N (Blue wire)
- PE (Green/Yellow wire)
Use 3x 0.35mm² stranded wires for DIM connections and 3x 1.04mm² stranded wires for AC/N, AC/L, PE connections.
Optional Reflector Installation
- Ensure power is OFF.
- Attach the reflector to the LED High Bay unit. [Reflector attachment diagram description: Reflector being fitted onto the luminaire.]
- Turn power ON. [Power On Symbol]
Optional Bracket Installation
- Ensure power is OFF.
- Attach the adjustable bracket to the LED High Bay fixture. [Bracket attachment diagram description: Bracket being mounted onto the luminaire.]
- Mount the fixture with the attached bracket to the desired surface. [Mounting diagram description: Fixture being installed on a ceiling or wall.]
- Secure the fixture properly.
- Connect the power supply wiring. [Wiring connection diagram description: Electrical connections being made.]
- Turn power ON. [Power On Symbol]