Attention: Installation should only be performed by individuals with electro-technical knowledge and experience. These products are not suitable for installation in locations near the sea or in environments with a corrosive atmosphere.

  1. Ensure the main power source is turned off. [Power Off Symbol]
  2. Connect the device to the mains supply using the terminal block*.
  3. Verify that the cables are securely connected to the terminals on the device.
  4. After installation is complete, activate the power source and test the function.

*Terminal block is not included.

Technical Data

Model Voltage Power/Wattage Useful Lumen Lumen Dimensions Beam Angle Color Temperature
LV70001AC220-240V100W13700LM17500LM169*126* dia 205 mm120°3000K
LV70002AC220-240V100W13700LM17500LM169*126* dia 205 mm120°4000K
LV70003AC220-240V100W13700LM17500LM169*126* dia 205 mm120°6500K
LV70004AC220-240V150W20500LM26500LM171*128* dia 235 mm120°4000K
LV70005AC220-240V150W20500LM26500LM171*128* dia 235 mm120°6500K
LV70006AC220-240V200W27300LM35000LM186.2*143.2* dia 265 mm120°4000K
LV70007AC220-240V200W27300LM35000LM186.2*143.2* dia 265 mm120°6500K
LV70008AC220-240V240W32700LM42000LM186.2*143.2* dia 265 mm120°4000K
LV70009AC220-240V240W32700LM42000LM186.2*143.2* dia 265 mm120°6500K
LV70057*AC220-240V150W20500LM26500LM171*128* dia 235 mm120°3000K
LV70058*AC220-240V200W27300LM35000LM186.2*143.2* dia 265 mm120°3000K
LV70059*AC220-240V240W32700LM42000LM186.2*143.2* dia 265 mm120°3000K
*These products are not GS Certified.

Accessories

High Bay Reflectors

SKUCompatible forBody type
LV70010100WAluminium
LV70011150WAluminium
LV70012150WAluminium
LV70013200W/240WAluminium
LV70014200W/240WAluminium

High Bay Adjustable Bracket

SKUCompatible forBody type
LV70014100-150-200-240WSteel

High Bay Sensor

SKUCompatible forVolt
LV70015100-150-200-240W100-277V

High Bay Sensor Remote Control

SKUCompatible for
LV70016100-150-200-240W

Installation Procedures

Manual Installation Steps

Follow these steps for manual installation:

  1. Step 1: Ensure power is OFF. [Power Off Symbol]
  2. Step 2: Connect wiring as per diagram. [Wire connection diagram description: Show connection of wires to terminals.]
  3. Step 3: Hang the fixture securely. [Hanging fixture diagram description: Fixture suspended from ceiling.]
  4. Step 4: Secure the fixture to the mounting surface. [Securing fixture diagram description: Fixture being attached to the ceiling.]
  5. Step 5: Connect power supply wires to the fixture. [Power connection diagram description: Mains power connected to the fixture terminals.]
  6. Step 6: Perform final checks. [Final check diagram description: Visual inspection of connections.]
  7. Step 7: Turn power ON. [Power On Symbol]

Important Notes:

  • The installation base must be able to support 10 times the weight of the product.
  • Maintain a minimum distance of 1 meter from lighted objects.
  • Replace any cracked protective shield before installation.

The product is certified by DEKRA for safety. [DEKRA Logo Description]

Dimmer Installation

For 100W - 150W - 200W Models:

Connect wires:

  • DIM+ (Brown wire)
  • DIM- (Blue wire)
  • AC/L (Brown wire)
  • AC/N (Blue wire)
  • PE (Green/Yellow wire)

Use 2x 0.35mm² stranded wires for DIM connections and 3x 1.04mm² stranded wires for AC/N, AC/L, PE connections.

For 240W Models:

Connect wires:

  • DIM+ (Purple wire)
  • DIM-/12V- (Pink wire)
  • 12V+ (Black/White wire)
  • AC/L (Brown wire)
  • AC/N (Blue wire)
  • PE (Green/Yellow wire)

Use 3x 0.35mm² stranded wires for DIM connections and 3x 1.04mm² stranded wires for AC/N, AC/L, PE connections.

Optional Reflector Installation

  1. Ensure power is OFF.
  2. Attach the reflector to the LED High Bay unit. [Reflector attachment diagram description: Reflector being fitted onto the luminaire.]
  3. Turn power ON. [Power On Symbol]

Optional Bracket Installation

  1. Ensure power is OFF.
  2. Attach the adjustable bracket to the LED High Bay fixture. [Bracket attachment diagram description: Bracket being mounted onto the luminaire.]
  3. Mount the fixture with the attached bracket to the desired surface. [Mounting diagram description: Fixture being installed on a ceiling or wall.]
  4. Secure the fixture properly.
  5. Connect the power supply wiring. [Wiring connection diagram description: Electrical connections being made.]
  6. Turn power ON. [Power On Symbol]
Models: LV70001, LV70002, LV70003, LV70004, LV70005, LV70006, LV70007, LV70008, LV70009, LV70057, LV70058, LV70059, LV70010, LV70011, LV70012, LV70013, LV70014, LV70015, LV70016, LV70001 LED High Bay, LV70001, LED High Bay, High Bay, Bay

File Info : application/pdf, 4 Pages, 3.08MB

PDF preview unavailable. Download the PDF instead.

lv70057-lv70059-manual

References

Adobe PDF Library 17.0 Adobe InDesign 19.4 (Macintosh)

Related Documents

Preview Ledvion LED High Bay Installation Manual and Specifications
Comprehensive installation guide and technical specifications for Ledvion LED High Bay lights, covering models LV70001 through LV70016. Includes safety precautions, installation steps, and accessory information.
Preview Ledvion LED High Bay Installation and Technical Guide
Comprehensive guide for installing and understanding the specifications of Ledvion LED High Bay lights, including technical data, accessories, and safety instructions.
Preview Ledvion LED Tube Installation Guide and Technical Specifications (LV20011-LV20016)
Comprehensive installation instructions and technical data for Ledvion LED Tubes, models LV20011 through LV20016. Learn about safe installation, wiring, and product specifications.
Preview Ledvion IP65 Fixture with T8 Fitting Installation Guide and Technical Data
Comprehensive installation instructions, technical specifications, safety guidelines, and compliance information for the Ledvion IP65 Fixture with T8 Fitting, covering models LV30001 through LV30006.
Preview Ledvion LV010083-D-2100K CE Certified Product Information
Official CE certification details for the Ledvion LV010083-D-2100K product. Visit the Ledvion website for more information regarding product certifications.
Preview Ledvion GU10 Ground Spot Installation Manual
Installation instructions and safety information for the Ledvion GU10 Ground Spot (ART.NO.LVO10137 & LVO10139). Includes details on electrical safety, maintenance, and disposal.
Preview Ledvion LVO10134 Outdoor Wall Lamp Installation Guide
Detailed installation instructions for the Ledvion LVO10134 outdoor wall lamp, featuring 9.5W, 1200 Lumen output, and 220-240 Volt compatibility. Includes safety precautions and step-by-step guidance.
Preview Ledvion LV010040 Outdoor Wall Lamp: Installation Guide & Safety Information
Comprehensive installation instructions, safety guidelines, and technical specifications for the Ledvion LV010040 outdoor wall lamp. Ensure safe and correct setup for your lighting.