AAON GPC-XP CONTROLLER

ASM01868

Stay in control with customizable control solutions. The GPC-XP Controller is used for controlling equipment or process that cannot be controlled using a standard HVAC controller.

PHYSICAL

Configurable Unit Controller that can be Used for Multiple Applications

The GPC-XP provides flexibility to control, schedule, and/or monitor equipment such as unit heaters, exhaust fans, motorized dampers, pumps, and other mechanical equipment. The GPC-XP can also be used for simple boiler, chiller, or refrigeration applications, as well as to provide one lead/lag start function.

The GPC-XP can function in either Stand-Alone or Network operation.

Allows Connection for Communicating Sensors

The GPC-XP has an on-board CommLink that provides for stand-alone programming and monitoring via a direct USB connection to a computer running Prism 2 software.

If used on a networked system that has an external CommLink, this on-board CommLink would not be used. Alternatively, the System Manager Touch Screen II for GPC-XP can be used to view status, perform force modes, and set schedules.

Electrical and Environmental

Operating Power 18-30 VAC
Operating Temperature -30°F to 150°F
Power Consumption 8 VA Maximum
Operating Humidity 0-95% RH Non-Condensing
Inputs 8 Analog Inputs (Configurable), 8 Wet-Contact Binary Inputs (Configurable)
Outputs 8 Relays, 4 Analog Outputs

INSTALLATION

Mounting

The GPC-XP is housed in a plastic enclosure. It is designed to be mounted using the three mounting holes in the enclosure base and the included mounting screws (#8 x 1" sheet metal screws).

The GPC-XP needs to be installed in an environment which can maintain a temperature range of -30°F to 150°F not to exceed 95% RH levels (Non-Condensing). It is important to mount the device in a location that is free from extreme high or low temperatures, moisture, dust, and dirt. Be careful not to damage the electronic components when mounting the controller.

Scan the code for additional product information [QR Code]

Technical Details and Wiring

RS-485 Communication Loop: Wire 'R' to 'R', 'T' to 'T', 'SHLD' to 'S'.

Relay Contact Rating: 1 AMP MAX @ 24 VAC.

Jumpers:

Analog Inputs: Settings must be set for specific input device requirements. It is recommended to write the description of the input and/or output on the controller using a permanent marker for future reference.

LED Blink Codes: Indicate Normal Operation or Schedule Override.

Power: Includes +24 VDC, +5 VDC, GND, +24 VAC terminals. WARNING! Polarity must be observed or the controller will be damaged.

USB E-BUS Port: For direct connection to a computer.

Dimensions: Approximate dimensions are provided in the diagram.

Models: ASM01868 Gpc Xp Controller, ASM01868, Gpc Xp Controller, Xp Controller, Controller

File Info : application/pdf, 2 Pages, 2.21MB

PDF preview unavailable. Download the PDF instead.

ASM01868-GPC-XP Controller-INSTL-A

References

Adobe PDF Library 17.0 Adobe InDesign 20.4 (Windows)

Related Documents

Preview AAON Duct Mounted CO2 Sensor ASM02236 - Technical Specifications and Installation
Detailed specifications and installation guide for the AAON Duct Mounted CO2 Sensor ASM02236. Covers physical, electrical, and environmental requirements, along with step-by-step mounting instructions.
Preview AAON GPC-XP System Manager Touch Screen II ASM01898 User Guide
This guide provides information on the AAON GPC-XP System Manager Touch Screen II (ASM01898), including its physical and electrical specifications, environmental requirements, and installation instructions. Learn how to interact with customizable control solutions for equipment and processes.
Preview AAON RSMV-HP ASM01693 Controller Installation and Specifications
This document provides installation and electrical/environmental specifications for the AAON RSMV-HP ASM01693 configurable unit controller, designed for HVAC systems.
Preview AAON System Manager TS-L ASM01900 Installation and Specifications
Detailed information on the AAON System Manager TS-L (SMTS-L) ASM01900, including its physical and electrical specifications, mounting instructions, and interaction with AAON controllers for HVAC system management.
Preview AAON MODGAS-X Controller ASM01668: Technical Specifications and Installation
Detailed information on the AAON MODGAS-X Controller ASM01668, including its physical and electrical specifications, environmental operating conditions, and mounting instructions for HVAC systems.
Preview AAON PREHEAT-X Module ASM01688 Installation and Specifications
Detailed information on the AAON PREHEAT-X Module ASM01688, including its physical, electrical, and environmental specifications, as well as mounting instructions. This module is designed for controlling electric heaters in HVAC systems.
Preview AAON PREHEAT-X-EXT Controller ASM01689 - Technical Specifications and Installation
Detailed technical specifications and installation guide for the AAON PREHEAT-X-EXT Controller (ASM01689). Learn about its physical and electrical features, operating parameters, and mounting instructions for HVAC systems.
Preview AAON ASM01870 BACnet General Controller: Installation and Specifications
This document provides detailed information on the AAON ASM01870 BACnet General Controller, including its physical and electrical specifications, mounting instructions, and capabilities for HVAC system control.