R. STAHL Load Disconnect Switches and Motor Starters

Molded Case Circuit Breaker for Motor Protection

Model: 8146/5-V27-201-115-02-21-1

Article No.: 249248

Key Features

Product Line: MY R. STAHL 8146N

Hazardous Area Classification: Suitable for Ex e and Ex d motors and associated conductors and systems.

The standard versions feature an adjustable, phase-sensitive thermal overcurrent release or an electromagnetic quick release, which must be specified during the ordering process. These features cannot be retrofitted.

Technical Data

Explosion Protection

Area of application European Union (ATEX), IECEx
Application range (zones) 1, 2, 21, 22
IECEX gas certificate IECEx PTB 06.0090
IECEx gas explosion protection Ex db eb IIC T5 Gb
IECEx dust certificate IECEx PTB 06.0090
IECEx dust explosion protection Ex tb IIIC T95 °C Db
ATEX gas certificate PTB 01 ATEX 1024
ATEX gas explosion protection II 2 G Ex db eb IIC T5 Gb
ATEX dust certificate PTB 01 ATEX 1024
ATEX dust explosion protection II 2 D Ex tb IIIC T95 °C Db
Certificates ATEX (PTB), Canada (FM), China (NEPSI), IECEx (PTB), India (PESO)
Declaration of conformity ATEX (EUK), China (CCC)

Electrical Data

AC release voltage -
Current-setting range 9 – 12.5 A
Ammeter present No
Auxiliary contacts 1 NO, 1 NC
Release without
No. of poles 3
Frequency range 50 – 60 Hz

Ambient Conditions

Ambient temperature -20°C ... +40°C (-4 °F ... +104 °F)

Mechanical Data

Degree of protection (IP) IP66
Degree of protection note according to EN/IEC 60529
Enclosure material Polyester resin, Glass fibre reinforced
Min. solid conn. cr.-sect. AWG AWG 16
Max. solid conn. cr.-sect. AWG AWG 8
Min. f.stra. con. cr.-sec. AWG AWG 16
Type of screw connection 8161
Width 170 mm (6.69 in)
Height 227 mm (8.94 in)
Depth 131 mm (5.16 in)
Handle colour Black
Protective collar colour Black
Rotary actuator labelling 0 – 1
Seal Silicone, foamed
Lockable in Three times in 0 position
Weight 3.2 kg (7.05 lb)

Components

Cable glands and entries 3 x M25 Ø 7 – 17 mm

Dimensional Drawings

All Dimensions in mm [inches] – Subject to Alterations

Diagram Description: The diagram shows a rectangular device with mounting holes and connection terminals. Key dimensions are labeled in millimeters and inches, including width (170mm / 6.69in), height (227mm / 8.94in), and depth (131mm / 5.16in). It also indicates the position of auxiliary contacts (1 NO, 1 NC) and cable entry points.

Cable entries

Version Auxiliary contacts Cable glands Series 8161 Stopping plugs Series 8290
Current-setting range up to 16 A without M25 x 1.5 M25 x 1.5
with A, B
A, B, C C
Current-setting range 16 to 20 A, 20 to 22.5 A without C C
with A, B A, B
A, B C

We reserve the right to make alterations to the technical data, dimensions, weights, designs and products available without notice. The illustrations cannot be considered binding.

Document Revision: 2025-07-22 V 0.132 EN

Manufacturer: R. STAHL Schaltgeräte GmbH | Am Bahnhof 30 | 74638 WALDENBURG

Contact: Tel. +49 7942 943 1700 | +49 7942 943 1777 | Email: sales.de@r-stahl.com | r-stahl.com

PDF preview unavailable. Download the PDF instead.

ex-single-data-sheet-mlded-case-circuit-breaker-for-motor-protection-8146-5-v27-201-115-02-21-1-249248-en-gb-rstahl Adobe PDF Library 17.0

Related Documents

Preview R. STAHL 8146/5-V27 Motor Protection Circuit Breaker
Technical data and specifications for the R. STAHL 8146/5-V27 molded case circuit breaker, designed for motor protection in hazardous environments (Ex e, Ex d). Includes details on explosion protection, electrical data, mechanical specifications, and component options.
Preview R. STAHL 8146/5-V27 Motor Protection Circuit Breaker - Technical Data
Detailed technical specifications and features of the R. STAHL 8146/5-V27 molded case circuit breaker for motor protection, including explosion protection, electrical data, and mechanical data.
Preview R. STAHL 8146/5-V27 Motor Protection Circuit Breaker - Technical Specifications
Detailed technical specifications for the R. STAHL 8146/5-V27 molded case circuit breaker, designed for motor protection in hazardous environments (Ex e, Ex d). Includes information on explosion protection, electrical data, mechanical data, and certifications.
Preview R. STAHL 8146/5-V27 Molded Case Circuit Breaker for Motor Protection
Technical specifications and data for the R. STAHL 8146/5-V27 molded case circuit breaker, designed for motor protection in Ex e and Ex d environments. Includes details on explosion protection, electrical data, mechanical data, and cable entries.
Preview R. STAHL 8146/5-V27 Molded Case Circuit Breaker for Motor Protection
Technical specifications and features of the R. STAHL Series 8146/5-V27 molded case circuit breaker for motor protection, designed for Ex e and Ex d motors and associated conductors and systems.
Preview R. STAHL 8146/5-V27 Molded Case Circuit Breaker for Motor Protection
Technical specifications and data for the R. STAHL 8146/5-V27 molded case circuit breaker, designed for motor protection in Ex e and Ex d applications. Includes explosion protection details, electrical data, and mechanical specifications.
Preview R. STAHL 8146/5-V27 Molded Case Circuit Breaker for Motor Protection - Technical Data
Detailed technical specifications and data for the R. STAHL 8146/5-V27 molded case circuit breaker for motor protection, including explosion protection, electrical data, mechanical data, and components.
Preview R. STAHL 8146/5-V27 Motor Protection Circuit Breaker - Technical Data
Technical specifications and features of the R. STAHL 8146/5-V27 molded case circuit breaker for motor protection, including explosion protection, electrical data, and mechanical data.