Hygiplas Mini Fridge/Freezer Thermometer
Instruction Manual
Model: CB891
Key Features
- Easy installation
- Large and clear digital display
- Out of safety zone alert
- Selectable temperature unit (°C/°F)
- Low battery indication
- Low power consumption
Specifications
Temperature Range | -25°C to 50°C / -13°F to 122°F |
---|---|
Display Accuracy | ±1°C / ±1.8°F over a full range |
Display Resolution | 0.1° over a full range |
Display Reading Update | 10 seconds |
Safety Zone Range | 0°C to 8°C / 32°F to 46.4°F |
Battery | 3 volt lithium, type CR2032 or equivalent, 1 piece |
Product Dimensions | 42 (H) x 71 (W) x 18 (D) mm |
Operation
Installation
- Unpack the thermometer with care.
- Press the [RESET] button once.
- Peel off the display protective sheet.
- Hang the thermometer onto the shelf inside the fridge or pull down the hanger to place it on the shelf.
- If the temperature is outside the safety zone of 0°C to 8°C (32°F to 46.4°F), the * symbol will flash to indicate that the temperature inside the fridge needs to be adjusted.
Select Temperature Unit
- Unscrew and open the back cover.
- Slide the °C/°F switch to the desired temperature unit.
- Put back the back cover and tighten the screws.
Notes, Symbols, and Compliance
Note: Before opening the back cover for battery replacement or changing the temperature unit, allow the thermometer to warm up to room temperature. Moisture may condense on electronic parts and damage the thermometer.
Symbols
Symbol | Description | Action Required |
---|---|---|
LLL | Low battery voltage | Replace the batteries |
HHH | 1. Sensor open circuit 2. Reading is out of low range (-25°C) | 1. Return the thermometer for repair 2. Keep the measurement above the low range |
HHH | 1. Sensor short circuit 2. Reading is out of high range (50°C) | 1. Return the thermometer for repair 2. Keep the measurement below the high range |
Compliance Information
Dispose of depleted batteries in accordance with local regulations. The EC has nominated disposal points for batteries.
The WEEE logo on this product or its documentation indicates that the product must not be disposed of as household waste. To prevent potential harm to human health and/or the environment, the product must be disposed of in an approved and environmentally safe recycling process. Contact the product supplier or the local authority responsible for waste disposal for more information.
HYGIPLAS parts undergo strict product testing to comply with regulatory standards and specifications set by international, independent, and federal authorities. HYGIPLAS products are approved to carry the CE symbol.
All rights reserved. No part of these instructions may be reproduced or transmitted in any form or by any means, electronic, mechanical, photocopying, recording, or otherwise, without prior written permission from HYGIPLAS.
Every effort is made to ensure all details are correct at the time of printing; however, HYGIPLAS reserves the right to change specifications without notice.
Declaration of Conformity
This product conforms to the following directives and standards:
- Electro-Magnetic Compatibility (EMC) Directive 2014/30/EU
- Restriction of Hazardous Substances Directive (RoHS) 2015/863
- EN 61326-1
Manufacturer: Hygiplas
Declaration Date: 30th April 2021
Contact Information
UK: 0845 146 2887, Fourth Way, Avonmouth, Bristol, BS11 8TB United Kingdom
Eire: 040-2628080, 42 North Point Business Park, New Mallow Road, Cork, Ireland
NL: 01 60 34 28 80
FR: 0800-29129
BE-NL: 0800-29129
BE-FR: 0800-29229
DE: 0800-1860806
ES: 901-100 133
PT: vendas@nisbets.pt