Pedrollo CP Centrifugal Pumps
Product Overview and Technical Specifications
Introduction
The Pedrollo CP series centrifugal pumps are designed for transferring clean water free from abrasive particles and liquids that will not damage the pump's components. They are reliable and easy to operate, finding extensive application in domestic and civil settings, particularly for distributing water with small to medium-sized pressure tanks, transferring fluids, and watering orchards and gardens.
The pumps feature an AISI 304 stainless steel impeller with a ten-year guarantee.
Applications:
- Clean water ?
- Domestic use ?
- Civil use ?️
Image description: A photograph of a Pedrollo CP centrifugal pump, showcasing its motor and pump housing.
Performance Range
- Flow rate up to 160 l/min (9.6 m³/h)
- Head up to 56 m
Electric Motor
The pumps are equipped with cutting-edge electric motors. Three-phase pumps are designed to work with inverters, offering stable and noiseless performance. They feature efficiency class IE3 for three-phase motors and IE2 for single-phase motors, bolstered by class F insulation and IPX4 protection.
Application Limits
- Manometric suction head up to 7 m
- Liquid temperature between -10 °C and +90 °C
- Ambient temperature up to +40 °C
- Maximum working pressure:
- 6 bar for CP 100-130-132-150-158
- 10 bar for CP 170-190-200
Available Upon Request
- Mechanical seal options available
- Protection rating IP X5 for CP 170, CP 170M
- Different voltage requirements, 60 Hz frequency
Patents - Trade Marks - Models
- CPm158 registered trademark no. 0001516350
- Registered community model no. 002098434
Performance Data (50 Hz)
Description of Performance Curves: The graph displays Head (H) in meters on the Y-axis against Flow Rate (Q) in liters per minute on the X-axis. Multiple curves represent different pump models (CP100 through CP200), showing their performance characteristics. Efficiency curves (η) are also indicated.
TYPE | POWER (P2) | Q m³/h | Q l/min | |||||||||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
kW | HP | 1~ | 3~ | 0 | 10 | 20 | 30 | 40 | 50 | 60 | 70 | 80 | 90 | 100 | 110 | 120 | 130 | 140 | 150 | 160 | ||
CPm 100 / CP 100 | 0.25 | 0.33 | 16 | 15 | 14 | 12.5 | 11 | 9 | 7 | |||||||||||||
CPm 130 / CP 130 | 0.37 | 0.50 | 23 | 22 | 21 | 20 | 19 | 18 | 17 | 15.5 | 14 | |||||||||||
CPm 132 / CP 132 | 0.55 | 0.75 | 23 | 22.5 | 22 | 21.5 | 21 | 20.5 | 19.5 | 18.5 | 17.5 | 16 | 14 | 12 | ||||||||
CPm 150 / CP 150 | 0.75 | 1 | 29.5 | 29 | 28.5 | 28 | 27.5 | 26.5 | 26 | 24.5 | 23 | 21 | 18 | 15 | ||||||||
CPm 158 / CP 158 | 0.75 | 1 | IE2 | IE3 | H metres | 36 | 34 | 33.5 | 33 | 32.5 | 31.5 | 30 | 28.5 | 27 | 25 | |||||||
CPm 170 / CP 170 | 1.1 | 1.5 | 41 | 38 | 37 | 36 | 35 | 33.5 | 32 | 30 | 27.5 | 25 | 22 | |||||||||
CPm 170M / CP 170M | 1.1 | 1.5 | 36 | 35 | 34.5 | 33.5 | 33 | 32 | 31 | 30 | 29 | 28 | 26.5 | 25 | 23 | 21 | 19 | |||||
CPm 190 / CP 190 | 1.5 | 2 | 48 | 46 | 44.5 | 43 | 41.5 | 40 | 38 | 36 | 34.5 | 32.5 | 30.5 | 28 | 26 | |||||||
CPm 200 / CP 200 | 2.2 | 3 | 56 | 55 | 54.5 | 53.5 | 52 | 51 | 49.5 | 48 | 46 | 44.5 | 42.5 | 40.5 | 38.5 | 36 |
Note: Performance curves comply with EN ISO 9906 Grade 3B tolerance limits. Q = Flow rate, H = Total manometric head, HS = Suction height.
Technical Data
Absorption
TYPE | VOLTAGE | TYPE | VOLTAGE | ||
---|---|---|---|---|---|
230 V | 400 V | 230 V - λ | 400 V - λ | ||
CPm 100 | 1.9 A | CP 100 | 1.6 A | 0.95 A | |
CPm 130 | 3.2 A | CP 130 | 2.0 A | 1.15 A | |
CPm 132 | 3.9 A | CP 132 | 2.2 A | 1.3 A | |
CPm 150 | 5.7 A | CP 150 | 4.2 A | 2.4 A | |
CPm 158 | 6.0 A | CP 158 | 4.3 A | 2.5 A | |
CPm 170 - 170M | 7.8 A | CP 170 - 170M | 5.2 A | 3.0 A | |
CPm 190 | 11.0 A | CP 190 | 7.4 A | 4.3 A | |
CPm 200 | 13.0 A | CP 200 | 9.3 A | 5.4 A |
Dimensions and Weight
Description of Dimension Diagram: The diagram illustrates the pump's dimensions with labels for inlet (DN1) and outlet (DN2) ports, and various measurements (a, f, h1, h2, h3, n1, n2, W, S).
TYPE | PORTS | DIMENSIONS mm | kg 1~ | kg 3~ | |||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|
DN1 | DN2 | a | f | h3 | h1 | h2 | n1 | n2 | W | S | |||
CPm 100 / CP 100 | 7.0 | 7.0 | |||||||||||
CPm 130 / CP 130 | 1" | 1" | 257 | 205 | 82 | 123 | 165 | 135 | 38 | 7.8 | 7.8 | ||
CPm 132 / CP 132 | 1" | 1" | 42 | 11 | 8.5 | 8.5 | |||||||
CPm 150 / CP 150 | 286 | 240 | 92 | 148 | 190 | 160 | 37 | 12.3 | 12.2 | ||||
CPm 158 / CP 158 | 12.4 | 12.3 | |||||||||||
CPm 170 / CP 170 | 1 1/4" | 1" | 367 | 260 | 110 | 150 | 206 | 165 | 44.5 | 19.1 | 17.6 | ||
CPm 170M / CP 170M | 19.3 | 17.9 | |||||||||||
CPm 190 / CP 190 | 1" | 1" | 364 | 290 | 115 | 175 | 242 | 206 | 36.5 | 21.6 | 21.5 | ||
CPm 200 / CP 200 | 384 | 24.6 | 24.6 |
Pallet Capacity
TYPE | NO. OF PUMPS |
---|---|
CPm 100 / CP 100 | 96 |
CPm 130 / CP 130 | 96 |
CPm 132 / CP 132 | 96 |
CPm 150 / CP 150 | 70 |
CPm 158 / CP 158 | 70 |
CPm 170 / CP 170 | 50 |
CPm 170M / CP 170M | 50 |
CPm 190 / CP 190 | 36 |
CPm 200 / CP 200 | 36 |
Construction Features
- Pump body: Cast iron with cataphoresis treatment with ISO 228/1 threaded ports.
- Cover: AISI 304 stainless steel (cast iron for models CP 170-170M-190-200).
- Impeller: Stainless steel AISI 304.
- Mechanical seal:
- CP 100-130-132: Seal AR-12, Shaft Ø 12 mm, Materials Ceramic / Graphite / NBR
- CP 150-158: Seal AR-14, Shaft Ø 14 mm, Materials Ceramic / Graphite / NBR
- CP 170-170M-190-200: Seal FN-18, Shaft Ø 18 mm, Materials Graphite / Ceramic / NBR
- Motor shaft: Stainless steel AISI 431.
- Electric motor:
- CPm: single-phase 230 V - 50 Hz with winding integrated thermal motor protection.
- CP: three-phase 230/400 V - 50 Hz.
- Pumps are equipped with high-efficiency motors (IEC 60034-30-1): class IE2 for single-phase models, class IE3 for three-phase models.
- Continuous running duty S1.
Description of Exploded View: The diagram shows the individual components of the pump assembly, numbered for identification: 1. Pump body, 2. Cover, 3. Impeller, 4. Mechanical seal, 5. Motor shaft, 6. Electric motor.