Schneider Electric Harmony XPSU Safety Module XPSUAT33A3AC
Product Data Sheet
Specifications
Product: Safety module, Harmony XPSU, Cat4, features XPSUAK with delayed outputs, 48 to 240V AC or DC, spring
Product ID: XPSUAT33A3AC
Product availability: Non-Stock - Not normally stocked in distribution facility
Main
Range of Product | Harmony Safety Automation |
Product or Component Type | Safety module |
Safety module name | XPSUAT |
Safety module application | Monitoring antivalent contacts For emergency stop, guard and light curtain monitoring Monitoring of pressure-sensitive 4-wire protective devices Emergency stop button with 2 NC contacts Guard monitoring with 1 or 2 limit switches Monitoring 2 PNP sensors Magnetic switch monitoring Light curtain monitoring RFID switch Monitoring of electro-sensitive protection equipment (ESPE) Sensing mat/edges Proximity sensor monitoring Monitoring 1 PNP + 1 NPN sensor |
Function of module | Emergency stop button with 2 NC contacts Guard monitoring with 1 or 2 limit switches Monitoring 2 PNP sensors Magnetic switch monitoring Light curtain monitoring RFID switch Monitoring of electro-sensitive protection equipment (ESPE) Sensing mat/edges Proximity sensor monitoring Monitoring 1 PNP + 1 NPN sensor |
Safety level | Can reach PL e/category 4 for normally open relay contact ISO 13849-1 Can reach SILCL 3 for normally open relay contact IEC 62061 Can reach SIL 3 for normally open relay contact IEC 61508 Can reach PL c/category 1 for normally closed relay contact ISO 13849-1 Can reach SILCL 1 for normally closed relay contact IEC 62061 Can reach SIL 1 for normally closed relay contact IEC 61508 |
Safety reliability data | MTTFd > 30 years ISO 13849-1 Dcavg >= 99% ISO 13849-1 PFHd = 1.47E-09 for SSO ISO 13849-1 PFHd = 1.48E-09 for SS1 ISO 13849-1 HFT = 1 IEC 62061 PFHd = 1.47E-09 for SSO IEC 62061 PFHd = 1.48E-09 for SS1 IEC 62061 SFF > 99% IEC 62061 HFT = 1 IEC 61508-1 PFHd = 1.47E-09 for SSO IEC 61508-1 PFHd = 1.48E-09 for SS1 IEC 61508-1 SFF > 99% IEC 61508-1 Type = B IEC 61508-1 |
Electrical circuit type | NC pair PNP pair Antivalent pair OSSD pair |
Connections - terminals | Removable spring terminal block, 0.2...2.5 mm² solid or flexible Removable spring terminal block, 0.25...2.5 mm² flexible with ferrule single conductor Removable spring terminal block, 0.2...1.5 mm² solid or flexible twin conductor Removable spring terminal block, 2 x 0.25...1 mm² flexible with ferrule without cable end, with bezel Removable spring terminal block, 2 x 0.5...1.5 mm² flexible with ferrule with cable end, with bezel |
[Us] Rated Supply Voltage | 48...240 V AC/DC - 10...10% |
Complementary
Synchronisation time between inputs | 0.5 s, 2 s, 4 s |
Type of start | Automatic/manual/monitored |
Power consumption in W | 4 W 48 V DC |
Power consumption in VA | 10 VA 240 V AC 50/60 Hz |
Input protection type | Internal, electronic |
Safety outputs | 1 NC configurable 3 NO configurable |
Safety inputs | 3 NO immediate 2 positive safety input 24 V DC 8 mA 1 negative safety input |
Maximum wire resistance | 500 Ohm |
Time delay range | 0...900 s |
Input compatibility | Normally closed circuit ISO 14119 XC limit switch ISO 14119 Mechanical contact ISO 14119 Normally closed circuit ISO 13850 Antivalent pair ISO 14119 OSSD pair IEC 61496-1-2 3-wire proximity sensors PNP |
[Ie] rated operational current | 5 A AC-1 for normally open relay contact 3 A AC-15 for normally open relay contact 5 A DC-1 for normally open relay contact 3 A DC-13 for normally open relay contact 3 A AC-1 for normally closed relay contact 1 A AC-15 for normally closed relay contact 3 A DC-1 for normally closed relay contact 1 A DC-13 for normally closed relay contact |
Control outputs | 4 on/off configurable pulsed output |
Input/output type | Pulsed output for diagnostics 24 V DC, 20 mA Z1, not safety-related Semiconductor output 24 V DC, 20 mA Z2, not safety-related |
[Ith] conventional free air thermal current | 16 A |
Associated fuse rating | 10 A gG NO relay output circuit IEC 60947-1 |
Minimum output current | 20 mA relay output |
Minimum output voltage | 24 V relay output |
Maximum response time on input | 20 ms |
[Ui] rated insulation voltage | 250 V IEC 60947-1 |
[Uimp] rated impulse withstand voltage | 4 kV II IEC 60947-1 |
Mounting Support | 35 mm symmetrical DIN rail |
Depth | 4.7 in (120 mm) |
Height | 3.9 in (100 mm) |
Width | 1.8 in (45 mm) |
Net Weight | 0.772 lb(US) (0.350 kg) |
Environment
Schneider Electric aims to achieve Net Zero status by 2050 through supply chain partnerships, lower impact materials, and circularity via its ongoing "Use Better, Use Longer, Use Again" campaign to extend product lifetimes and recyclability.
Environmental footprint
Carbon footprint (kg CO2 eq, Total Life cycle) | 139 |
Environmental Disclosure | Product Environmental Profile |
Materials and Substances
Packaging made with recycled cardboard | Yes |
Packaging without single use plastic | No |
EU RoHS Directive | Pro-active compliance (Product out of EU RoHS legal scope) |
SCIP Number | 152cf799-1df7-4892-81b4-4c890187f1d1 |
REACH Regulation | REACH Declaration |
California proposition 65 | WARNING: This product can expose you to chemicals including: Lead and lead compounds, which is known to the State of California to cause cancer and birth defects or other reproductive harm. For more information go to www.P65Warnings.ca.gov |
PVC free | Yes |
Repack and remanufacture
Circularity Profile | End of Life Information |
Take-back | No |
WEEE | The product must be disposed on European Union markets following specific waste collection and never end up in rubbish bins. |
Standards
- IEC 60947-5-1
- IEC 61508-1 functional safety standard
- IEC 61508-2 functional safety standard
- IEC 61508-3 functional safety standard
- IEC 61508-4 functional safety standard
- IEC 61508-5 functional safety standard
- IEC 61508-6 functional safety standard
- IEC 61508-7 functional safety standard
- ISO 13849-1 functional safety standard
- IEC 62061 functional safety standard
Product Certifications
- TÜV
- cULus
IP degree of protection
- IP54 mounting area) IEC 60947-1
- IP40 housing)IEC 60947-1
- IP20 terminals)IEC 60947-1
Ambient Air Temperature for Storage
-13...185 °F (-25...85 °C)
Relative Humidity
5...95% non-condensing
Ordering and shipping details
Category | US1SAF222477 |
Discount Schedule | SAF2 |
GTIN | 3606489601706 |
Returnability | No |
Country of origin | ID |
Packing Units
Unit Type of Package 1
Unit Type | PCE |
Number of Units in Package | 1 |
Package 1 Height | 2.68 in (6.800 cm) |
Package 1 Width | 5.51 in (14.000 cm) |
Package 1 Length | 6.22 in (15.800 cm) |
Package 1 Weight | 16.226 oz (460.000 g) |
Unit Type of Package 2
Unit Type | S03 |
Number of Units in Package | 16 |
Package 2 Height | 11.81 in (30.000 cm) |
Package 2 Width | 11.81 in (30.000 cm) |
Package 2 Length | 15.75 in (40.000 cm) |
Package 2 Weight | 18.012 lb(US) (8.170 kg) |
Dimensions Drawings
Dimensions
Front and Side Views
(A): Product drawing
(B): Spring Terminal
(C): Side view
(1): Removable terminal blocks, top
(2): Removable terminal blocks, bottom
(3): LED indicators
(4): Start function selector
(5): Function selector
(6): Delay factor selector
(7): Delay base selector
(8): Connector for optional output extension module (lateral)
(9): Sealable transparent cover
Wire Gauge Compatibility:
mm² | 0.2...2.5 | 0.25...2.5 | 0.2...1.5 | 0.25...1 | 0.5...1.5 |
AWG | 24...12 | 24...12 | 24...16 | 24...18 | 20...16 |
Mounting and Clearance
Mounting to DIN rail
Diagram showing the process of mounting the module to a DIN rail, with indicators for correct placement and clearance.
Screw-mounting
Diagram illustrating screw-mounting options with M4 x 12/16 screws and M4 (ISO 7093) washers, indicating dimensions for mounting holes.
Connections and Schema
Wiring Drawing
Terminal Designations:
- A1-A2: Power supply
- S11-S12-S21-S22-S31-S32: Single-channel safety input
- Y1-Y2: Start
- 13-23-33-47-57-67-75: Output
- 14-24-34-48-58-68-76: Output
- EXT: Connector for optional extension module
- B2: Common ground terminal
- Z1: Pulsed output for diagnostics, not safety-related
- Z2: Solid state output, not safety-related
Diagram showing the internal wiring and connections of the safety module, including power supply, safety inputs, start function, outputs, and optional extension module connector.
Image of product / Alternate images
Images of the Schneider Electric Harmony XPSU safety module, showing front and side views with labeled components and connections.
Environmental Data
Schneider Electric is committed to achieving Net Zero status by 2050 through supply chain partnerships, lower impact materials, and circularity initiatives.
Environmental footprint
Carbon footprint (kg CO2 eq, Total Life cycle): 139
Environmental Disclosure: Refer to the Product Environmental Profile for detailed information.
Materials and Substances
- Packaging made with recycled cardboard: Yes
- Packaging without single use plastic: No
- EU RoHS Directive: Pro-active compliance (Product out of EU RoHS legal scope)
- SCIP Number: 152cf799-1df7-4892-81b4-4c890187f1d1
- REACH Regulation: Refer to the REACH Declaration.
- California proposition 65: WARNING: This product can expose you to chemicals including: Lead and lead compounds, which is known to the State of California to cause cancer and birth defects or other reproductive harm. For more information go to www.P65Warnings.ca.gov
- PVC free: Yes
Repack and remanufacture
- Circularity Profile: Refer to End of Life Information.
- Take-back: No
- WEEE: The product must be disposed of on European Union markets following specific waste collection procedures and must never end up in rubbish bins.