Aquaguard Astor Water Purifier User Manual
Why Choose Aquaguard®?
- Has the trust of over 15 million mothers*
- Is owned by over 1.62 lakh doctors
- Has service with 5 kms. range of wherever you are
- Has over 21 different technologies to address 21 different water conditions across the country
- Is certified by over 135 leading national and international laboratories
- Is sold in over 35 countries worldwide
*As per Superbrands & Reader's Digest.
Installing Your Aquaguard® Astor
Ensure your Aquaguard® Astor is installed by a trained Eureka Forbes Service Technician only.
- Input water must be tested for Total Dissolved Solids (TDS) and Total Hardness.
- Install your Aquaguard® Astor in a dry ventilated place. Keep it away from direct sunlight, heating devices, or areas below freezing temperatures. It can be placed on the kitchen counter or wall-mounted. The purifier should be in an area free of ants/insects/other pests.
- Ensure that the input tap water temperature is in the range of 10°-40°C. Avoid installation to a hot water tap as it can damage the filters.
- Ensure that the input water pressure for Astor RO+UV+MTDS/RO models is from 0.3 kg/cm² - 3.0 kg/cm² and for Astor UV+UF models is from 0.3 kg/cm² - 2.0 kg/cm². If the input water pressure is more than specified, installation of a PRV (Pressure Reducing Valve)* is mandatory. If the input water pressure is less than specified, installation of a booster pump is recommended.
- Flush filter thoroughly and independently for 3-5 minutes to remove fine particles present in the filter before installation.
- After installing, run the purifier for 5-10 minutes and drain this water.
Input water quality usage limitations:
- If the input water iron content is more than 0.3 mg/litre, use of an iron remover* is recommended as a pre-treatment.
- If the input water turbidity is more than 5 NTU or comprises colloidal particles, use of a special filter* is required as a pre-filter.
- Do not install the water purifier if the TDS is more than that prescribed in the technical specifications.
*Available at an extra cost.
MTDS Regulator Operating Procedure (Only Applicable for RO+UV+MTDS models)
The TDS modulator is located inside the product. As per factory setting, it comes in fully closed mode. The TDS level of output water can be increased by slowly loosening the spindle of the TDS modulator (anticlockwise). Normally, a slight quarter turn is enough to increase the TDS of the output water. Rotating the spindle in the clockwise direction closes the TDS modulator and reduces the level of TDS blending. Please note that the TDS blending and its adjustment is dependent upon the level of TDS of input water and on the TDS reduction capacity of the RO membrane. TDS adjustment should be done by the authorized Eureka Forbes technician only.
Aquaguard Astor UV+UF Purification Process
This diagram illustrates the water purification journey. Input water first passes through the i-Filter™ to remove suspended particles. It then moves to the Chemi-Block, which uses activated carbon to remove chlorine, odor, and organic impurities. Next, the Ultra Filter (UF Hollow Fiber) clarifies the water and removes bacteriological contaminants. The water is then disinfected by UV e-boiling using a UV lamp. Finally, it passes through the Active Copper™ stage, which enhances taste and provides antimicrobial benefits, before reaching the output.
Stage | Treatment | Material | Benefits |
---|---|---|---|
1 | i-Filter™ | Multi-layered Polypropylene roving wound cartridge | Removes fine suspended particles such as dust, dirt, mud and sand from water. |
2 | Chemi-Block (with built-in Particle Trap Filter™) | Dust Free Bacteriostatic Activated Carbon Block | Reduces excess chlorine, bad odour, colour and organic impurities. It also removes very fine turbidity causing particles. |
3 | Ultra Filter | UF Hollow Fiber Capillary tube type membrane-based technology | Imparts crystal clear clarity to drinking water in addition to making the water safe from bacteriological contamination. |
4 | UV e-boiling | Germicidal UV Lamp | UV disinfects the water by eliminating waterborne disease-causing bacteria, viruses and protozoa, thereby making it safe to drink. |
5 | Active Copper™ | Bacteriostatic Taste Enhancer with Active Copper™ Technology | Copper has antimicrobial, antioxidant, and anti-inflammatory properties that help to support healthy metabolism. It also helps to provide the body with energy and is much needed for growth and development. The activated carbon removes organic components and polishes the water, giving it a sparkling look, making it pure and great to taste. |
Aquaguard Astor UV+UF Technical Specifications
# | Technical Parameters | Specifications |
---|---|---|
PRODUCT SPECIFICATION | ||
1 | Model | Aquaguard Astor UV+UF |
2 | Purification Technology | UV+UF |
3 | Dimension (WXDXH) | 476 mm X 278 mm X 320 mm |
4 | Net Weight | 4.5 kg (Approx.) |
5 | Tank Capacity | 6.2 Litres (approx.) |
6 | Standard Filtration | i-Filter™, Chemi-Block, UF Filter, UV e-boiling, Active Copper™ |
ELECTRICAL SPECIFICATIONS | ||
1 | Power Rating | 20 Watts (Max.) |
2 | Power Supply | Input 230VAC, 50Hz. Output: 12V. (ON Board AC-DC) |
3 | UV Lamp | 11 Watts |
4 | UV Lamp Life | 8000 burning hours (as per manufacturer's spec.) |
5 | Operating Voltage Range | 150VAC to 250 VAC, 50 Hz |
RECOMMENDED INPUT WATER PARAMETERS | ||
1 | Input Water Pressure Range** | 0.3 to 2.0 kg/cm². |
2 | Input Iron (Max.) | 0.3 mg/L |
3 | Input Chlorine Content (Max.) | 0.2 mg/L |
4 | Input Water Turbidity (Max.) | 5 NTU |
5 | Total Dissolved Solids (TDS) (max.) | Up to 200 mg/L |
6 | Input Water Temperature | 10°C to 40°C |
*Technical Specifications are subject to change without prior notice.
Note: SMPS is designed to operate from 150VAC to 280VAC.
Note: The performance data presented in the table is applicable under standard laboratory conditions. Actual performance may vary depending on the input water quality, water pressure and condition of filters. Input water quality/pressure/TDS are important determinants of recovery rate and rejection.
**If the input water pressure is more than 2.0 kg/cm², installation of a PRV (Pressure Reducing Valve) is mandatory. If the input water pressure is less than 0.3 kg/cm², installation of a booster pump is recommended. These accessories are available at an extra cost.
Warranty void if not installed as per recommendations.
#Standard Test Conditions: Feed Water Quality: TDS Max: 200 mg/L, Pressure: 1 kg/cm², Turbidity: 1 NTU (Max.), Temperature: 25°C, Chlorine: below 0.2 mg/L, Iron: below 0.3 mg/L, Life: 6000 liters
LED Indication Chart for Aquaguard® Astor UV+UF
LED Indication | UV+UF | Remarks |
---|---|---|
Power | Blue LED will be Solid if Power is Available. | Power |
Purification Process | Red, Green, and Blue will glow one after other for 1 sec. | Tank filling mode |
Service | Blue LED will be Solid | Tank Full |
Tank Full | Red LED will be Solid | UV Lamp Error |
Power | Blue LED will be Solid | Storage (Tank Full) |
Service | Red LED will Blink at 0.5 sec Rate | SV Error |
Tank Full | Green LED will be OFF | |
Power | Blue LED wil Blink at 0.25 sec Rate | |
Service | Red LED will be OFF | |
Tank Full | Green LED will be OFF | |
Green LED will Blink at 0.5 sec Rate for 30 secs | ||
Green LED will Blink at 0.5 sec Rate continuously | ||
Green LED will be solid | ||
Blue LED will be Solid | ||
Red LED will be OFF | ||
Blue LED will be Solid | ||
Red LED will be OFF | ||
Green LED will be solid | ||
Blue LED will be Solid |
Aquaguard Astor RO+UV+MTDS Purification Process
This section details the purification stages for the RO+UV+MTDS models. Water enters and passes through a Sediment Filter to remove larger particles. It then goes through an Activated Carbon Filter to remove chlorine and organic compounds. The core purification happens at the RO Membrane, which removes dissolved salts, hardness, heavy metals, and microorganisms. After RO, the water is disinfected by UV Disinfection. A Mineral Cartridge is used to enhance taste and add essential minerals. Finally, the MTDS Controller allows for adjustment of the TDS level in the output water.
Stage | Treatment | Material | Benefits |
---|---|---|---|
1 | i-Filter™ | Multi-layered Polypropylene roving wound cartridge | Removes fine suspended particles such as dust, dirt, mud and sand from water. |
2 | Chemi-Block | Dust Free Bacteriostatic Activated Carbon Block | Reduces excess chlorine, bad odour, colour and organic impurities. It also removes very fine turbidity causing particles. |
3 | RO Membrane | Thin film composite polyamide | Removes dissolved salts, hardness, heavy metals, arsenic, fluoride, virus and bacteria. |
4 | UV e-boiling | Germicidal UV Lamp | UV disinfects the water by eliminating waterborne disease-causing bacteria, viruses and protozoa, thereby making it safe to drink. |
5 | Mineral Guard™ | Activated Carbon | Enhances taste and adds essential minerals. |
6 | MTDS Controller | - | Allows adjustment of TDS level in output water. |
Aquaguard Astor RO Technical Specifications
# | Technical Parameters | Specifications |
---|---|---|
PRODUCT SPECIFICATION | ||
1 | Model | Aquaguard Astor RO+UV+MTDS |
2 | Purification Technology | RO+UV+MTDS |
3 | Dimension (WXDXH) | 476 mm X 278 mm X 320 mm |
4 | Net Weight | 4.5 kg (Approx.) |
5 | Tank Capacity | 6.2 Litres (approx.) |
6 | Standard Filtration | i-Filter™, Chemi-Block, RO Membrane, UV e-boiling, Mineral Guard™, MTDS Controller |
ELECTRICAL SPECIFICATIONS | ||
1 | Power Rating | 25 Watts (Max.) |
2 | Power Supply | Input 230VAC, 50Hz. Output: 24V. (ON Board AC-DC) |
3 | UV Lamp | 11 Watts |
4 | UV Lamp Life | 8000 burning hours (as per manufacturer's spec.) |
5 | Operating Voltage Range | 150VAC to 250 VAC, 50 Hz |
RECOMMENDED INPUT WATER PARAMETERS | ||
1 | Input Water Pressure Range** | 0.3 to 3.0 kg/cm². |
2 | Input Iron (Max.) | 0.3 mg/L |
3 | Input Chlorine Content (Max.) | 0.2 mg/L |
4 | Input Water Turbidity (Max.) | 5 NTU |
5 | Total Dissolved Solids (TDS) (max.) | Up to 2000 mg/L |
6 | Input Water Temperature | 10°C to 40°C |
*Technical Specifications are subject to change without prior notice.
Note: SMPS is designed to operate from 150VAC to 280VAC.
Note: The performance data presented in the table is applicable under standard laboratory conditions. Actual performance may vary depending on the input water quality, water pressure and condition of filters. Input water quality/pressure/TDS are important determinants of recovery rate and rejection.
**If the input water pressure is more than 3.0 kg/cm², installation of a PRV (Pressure Reducing Valve) is mandatory. If the input water pressure is less than 0.3 kg/cm², installation of a booster pump is recommended. These accessories are available at an extra cost.
Warranty void if not installed as per recommendations.
#Standard Test Conditions: Feed Water Quality: TDS Max: 2000 mg/L, Pressure: 1 kg/cm², Turbidity: 1 NTU (Max.), Temperature: 25°C, Chlorine: below 0.2 mg/L, Iron: below 0.3 mg/L, Life: 6000 liters
LED Indication Chart for Aquaguard® Astor RO+MTDS
LED Indication | RO+MTDS | Remarks |
---|---|---|
Power | Blue LED will be Solid if Power is Available. | Power |
Purification Process | Red, Green, and Blue will glow one after other for 1 sec. | Tank filling mode |
Service | Blue LED will be Solid | Tank Full |
Tank Full | Red LED will be Solid | UV Lamp Error |
Power | Blue LED will be Solid | Storage (Tank Full) |
Service | Red LED will Blink at 0.5 sec Rate | SV Error |
Tank Full | Green LED will be OFF | |
Power | Blue LED wil Blink at 0.25 sec Rate | |
Service | Red LED will be OFF | |
Tank Full | Green LED will be OFF | |
Green LED will Blink at 0.5 sec Rate for 30 secs | ||
Green LED will Blink at 0.5 sec Rate continuously | ||
Green LED will be solid | ||
Blue LED will be Solid | ||
Red LED will be OFF | ||
Blue LED will be Solid | ||
Red LED will be OFF | ||
Green LED will be solid | ||
Blue LED will be Solid |
Tips for Safety and Maintenance
Regular cleaning and maintenance are crucial for the optimal performance and longevity of your Aquaguard Astor water purifier. Refer to the detailed sections on cleaning and disinfection of the storage tank and general maintenance tips provided in the full manual.