Hager EG103E/EG103V Electronic Time Switch
User Instruction
Product Overview
EG103E with Override Entry
EG103V with 12-24V Voltage Supply
Major Characteristics
- Product delivered with current time and date set.
- Automatic change of winter/summer time ☀️/❄️.
- Programming key ?: for permanent waivers, for program copy or save.
- Programming by day or group of days.
- 56 program steps: On, Off, or impulses (1 sec to 30 min).
- Permanent overrides: On or Off (?).
- Temporary overrides: On or Off (⚡ flashing).
- Holiday mode: overrides On or Off between two dates ?️.
- Simulation of presence ?.
- Display bar graph of daily profile.
- Keyboard locking possible.
- Programmable with power off.
- Backlit display (EG103E only).
Controls and Navigation
Keys
menu
☰: Select operating mode (auto, prog new, prog modif, check program, time/date/DST change, holidays).+
➕ and-
➖: Navigate or set values. In auto mode,-
selects overrides, waivers, or random operation.ok
✔️: Validate flashing information.↶
[back]: Return to the previous step.
You can return to auto mode at any moment using menu
. If no action is taken for 1 minute, the switch returns to auto mode.
Programming Features
Programming (prog new
)
Programming can be done per day or per group of days. Instructions are common to several days.
Days: 1 = Monday, 2 = Tuesday, ..., 7 = Sunday.
- Select the
prog new
mode usingmenu
, thenok
. The number of free program steps appears briefly. - Select the day(s) using
+
or-
. Validate withok
. ok
flashes. Validate the group of days using theok
button. Use+
or-
to redo the group if necessary.- Using
+
or-
, select the state of the instruction:On
,Off
, or ⚡ (impulse). Pressok
to validate the state. - Enter the switch-on time using
+
or-
. Validate withok
. - Enter minutes using
+
or-
. Validate withok
. - For an impulse (⚡), set the duration (seconds, then minutes) in the same way as the switch-on schedule.
Program other instructions for the group of days by repeating steps 3 to 7. The day or group of days can be modified during step 3 by pressing +
, -
, or ↶
. At the end of programming, return to auto mode using menu
. You can also add an instruction to the established program in this mode.
Display (Visualisation)
To check the daily profile set up without risk of modification or deletion:
- Select the mode using
menu
and pressok
. The first step of Monday is displayed along with the daily profile. - Two options for display:
- Pressing
+
or-
: shifts between days. Only the first step of the day and the daily profile are displayed. - Pressing
ok
: all steps of each day scroll one after another.
- Pressing
Modification or Clearing a Program Step (prog modif
)
Select the prog modif
mode with menu
and ok
. Select the modif
mode with +
or -
. Validate with ok
.
The number of remaining program steps appears briefly. The first step of the first day or group of days appears. Repeatedly pressing ok
scrolls through all programmed steps.
Any flashing field (state, hour, minutes) can be modified using +
or -
, then validated with ok
.
When the cursor is on ok
behind the group of days, you can scroll through days or groups of days to directly access the one to be modified using +
or -
.
To remove a program step: select the state (On
, Off
, or ⚡), press +
and -
simultaneously. Clear
appears on the screen. Validate with ok
.
Advanced Functions
Holidays (Vacances) ?️
Allows overriding the output to On
or Off
for a specific period. This override is temporary and not carried over to the next year.
- Select the mode using
menu
thenok
. - Using
+
or-
, choose the override state:On
orOff
. Validate withok
. - Enter the start date (day, month) using
+
or-
, thenok
. - Enter the end date (day, month) similarly.
In auto mode, ?️ flashes to indicate a holiday period is programmed. It becomes fixed ? during the period. The override is effective from 0:00 of the 1st date until 23:59 of the 2nd date.
If the start date is before the current programming date, the holiday period is valid for the following year.
To clear a holiday period, return to the mode, press +
and -
simultaneously. Clear
appears. Confirm with ok
.
Override - Temporary / Permanent / Random Operation
In auto mode, pressing -
repeatedly cycles through states:
- 1st press: Temporary waiver (
Off
and ⚡ flashing). Returns to automatic mode at the next program step. - 2nd press: Permanent override (
On
and ? fixed). Must be cancelled manually. - 3rd press: Permanent override (
Off
and ? fixed). Must be cancelled manually. - 4th press: Random operation (? displayed). Simulation of presence. Program steps are shifted randomly within ± 59 minutes. Must be cancelled manually.
- 5th press: Return to automatic mode.
Programming Key ?
When the key is present, ? appears on the screen.
Two types of operation:
A. Permanent Override: Insert the key. After 10 seconds, the program from the key executes without clearing the device's program. The device's program becomes valid again upon key removal.
B. Copy (load) / Save (save): The key allows saving a program from the time switch or copying a program from the key to the time switch.
- Insert the key and wait 2 seconds.
- Using
menu
, select the mode:save
(save program from device),load
(load program from key), or check program on key. - Validate the choice with
ok
. - For
save
andload
, reconfirm withok
.
Possible error messages:
no prog
: The key is empty.Error
: The key is for a 2-channel switch.
In case of errors, only save
is possible. The error message remains, but the device's program executes.
Time and Date Settings
Setting Time and Day
Select the mode with menu
then ok
. Modify the day, month, year, hour, and minutes using +
or -
and ok
.
Winter/Summer Time Change ☀️/❄️
The time switch suggests winter/summer time changes. Select the desired change type using +
or -
, then validate with ok
.
The type of change depends on the geographical zone. Available types include Euro, USA, GB, AUS, and USER.
For the USER type, you can freely program the dates for summer time (+1 hour) and winter time (-1 hour) changes. Changes always occur between 2:00 and 3:00 AM.
Remote Override (EG103E Only)
Allows temporary overrides remotely. When 230V is applied to terminal 7 via a non-lighted push-button, the time switch state reverses until the next program step.
Keyboard Locking
To prevent accidental operation, the keyboard can be locked using a key (EG004). Unlocking is performed the same way.
Reset Procedures
- Program Reset: Simultaneously press
menu
,ok
, and↶
. The time and date are maintained. - Total Reset: Simultaneously press
-
,+
,ok
, andmenu
. This clears all product content. After a total reset, the time and day must be reset.
Technical Specifications
Characteristic | Details |
---|---|
Electrical Characteristics | |
Supply Voltage | EG103E: 230 V AC ± 15% EG103V: 12 V AC/DC +20% -10%, 24 V AC/DC +10% -15% |
Frequency | 50/60 Hz |
Power Consumption | EG103E: max. 6 VA @ 50 Hz EG103V: max. 0.8 VA @ 50 Hz |
Output | 1 changeover volt-free contacts |
Maximum Load | AC1: 16A 250 V~ DC1: 4A 12 V Cos φ = 0.6: 10A 250 V~ Incandescent Lighting: 2300 W Halogen Lighting 230 V: 2300 W Compensated Fluorescent Tubes: 400 W Non-compensated/Series compensated Fluorescent Tubes: 1000 W Compact Fluorescent Lamps: 500 W |
Minimum Current | AC1: 100 mA 250 V~ DC1: 100 mA 12 V |
Galvanic Insulation | Between power supply and output = 4 kV |
Functional Characteristics | |
Programming Capacity | 56 steps |
Minimum Time Between Steps | 1 minute |
Running Accuracy | ± 1.5 sec / 24h |
Operating Reserve | Lithium battery provides 5 years of backup. |
Standby Mode | Display switches off after 1 minute of power off. Returns to auto mode upon power restoration or key press. |
Protection Degree | IP 20 |
Environment | |
Operating Temperature | -5 °C to +45 °C |
Storage Temperature | -20 °C to +70 °C |
Connection | |
Flexible Cable Capacity | 1 to 6 mm² |
Rigid Cable Capacity | 1.5 to 10 mm² |
Connection Diagram
The diagram illustrates the terminal layout for the EG103E. Terminals are labeled L/+, N/-, and numbered 1 through 8. Terminals 1, 3, 5, 7 are grouped on one side, and 2, 4, 6, 8 on the other.
Warranty Information
Hager products are covered by a 24-month warranty against material or manufacturing defects from the date of manufacture. In case of a defect, the product must be returned via the installer and usual wholesaler. The warranty is void if the installation is contrary to regulations, if the return procedure is not followed, or if the defect is due to improper installation or use. Explanations of the defect must accompany the returned product.