Main Buttons

1 - Power Button: Press briefly to turn on, press and hold for 2 seconds to turn off. In working mode, press to adjust display brightness.

2 - LED Light Button: Press to activate the LED light.

3 - Tire Pressure Preset Button: Set the desired tire pressure. The numbers will blink after setting the pressure. Blinking will stop upon completion. You can exit the setting mode. The display will show the real-time tire pressure.

4 - BAR/PSI Unit Switch: Press and hold for 5 seconds to switch to emergency start mode.

5 - Compressor On/Off Button: Press and hold for 3 seconds to turn on, press briefly to turn off.

Function Description

Display Modes

a) Charging Display: Shows battery level and power status during charging.

b) Discharging Display: Shows battery level and discharge power when discharging via USB.

Input and Output Ports

1 - EC8 Output Port: For connecting jumper clamps.

2 - Charging and Discharging Port (USB-C): For charging the device and discharging power.

3 - Device Discharging Port (USB-A): For discharging power to devices.

4 - Compressor Output Port: For connecting the air hose.

2. Technical Specifications

Capacity 12V Starting Voltage Peak Current Battery Type Storage Temperature Operating Temperature Charging Temperature
74.37 Wh 12V 2500A Li-pol -20°C to +50°C -20°C to +60°C 0°C to +45°C

Output

Input

LED Flashlight Brightness: 300 Lumens

Compressor Pressure: Max. 10 Bar (145 PSI)

3. Package Contents

4. Using the Device

A. Turning on the Device

Press the power button ? or the LED light button to activate the device.

B. Using the Device for Starting

Method 1: Normal Start

  1. Ensure the vehicle's electrical system is 12V DC.
  2. Connect the red (+) clamp to the positive (+) terminal of the car battery and the black (-) clamp to the negative (-) terminal. Ensure a secure connection.
  3. Activate the device by briefly pressing the LED light button ? or the power button. A 10-second countdown will begin to check the clamp connection. If the indicator blinks after the countdown, the vehicle is ready to start.
  4. Immediately after the vehicle starts, remove the clamps from the battery. Press and hold the power button for 2 seconds to turn off the device. If no operation is performed for 6 seconds, the device will automatically turn off.
  5. If the vehicle does not start, check the clamp connections and try again. Do not attempt to start the vehicle more than 5 times within 15 minutes.

Method 2: Emergency Start

Safety Warning: Exercise extreme caution when using this mode. Ensure the (+) and (-) clamps do not touch each other to prevent electric shock, short circuits, device damage, battery damage, or fire.

  1. If normal starting is unsuccessful (e.g., battery voltage is too low), you can use the emergency start function after carefully reading the manual.
  2. Connect the jumper cable clamps to the EC8 connector on the device.
  3. Connect the red (+) clamp to the positive (+) terminal of the car battery.
  4. With the device on, press and hold the BAR/PSI button for 5 seconds to activate emergency start mode. The start indicator will light up, showing the clamps are active.
  5. Connect the black (-) clamp to the negative (-) terminal of the car battery, ensuring a secure connection. The display will show the total voltage. You can now attempt to start the vehicle.
  6. After a successful start, press the BAR/PSI or PUMP button to turn off.

Clamp Connection Status (Connect Max)

During the start mode, a 10-second countdown begins after connecting the clamps to check the battery and connection. If the connection impedance is low, the clamp status indicator will be green. If it's high, it will be yellow.

During the countdown, you can adjust the clamp connection. After 10 seconds, you must end the start mode and reconnect the clamps to measure the impedance again.

When the Lokithor is in forced start mode, the clamp status indicator will always blink yellow to warn of caution during use.

C. Using the Voltmeter

  1. Connect the red (+) clamp to the positive (+) terminal of the car battery and the black (-) clamp to the negative (-) terminal, ensuring a correct connection.
  2. After the 10-second interval, the status indicator on the main panel will light up, showing the current battery voltage.
  3. After measurement, disconnect the clamps from the battery terminals.

4. Using the Device (Continued)

D. Using the Light

  1. Press and hold the "LED Light" button ? for approximately 1 second to turn on the LED light.
  2. Briefly press the "LED Light" button to cycle through modes: steady light, strobe, SOS, and off.
  3. To turn off the device, press and hold the "LED Light" button for approximately 2 seconds.

E. Charging the Device

The device can be charged using:

Connect the USB-C end of the cable to the device's charging port and the other end (USB-C or USB-A) to the charger.

The power indicator lighting up means the device is charging correctly.

If the battery indicator is yellow or red, charge the device immediately to prevent deep discharge. Do not leave the device in a discharged state for extended periods.

F. Charging a Mobile Phone via USB-A / USB-C

The device can charge mobile phones using USB-A / USB-C or USB-C / USB-C cables.

G. Using the Compressor

Attach the inflatable hose to the air compressor outlet, tighten the nut, and connect the other end to the tire valve.

Press the power button ? or the LED light button to activate the device.

Briefly press the BAR/PSI button to switch between tire pressure units: BAR, PSI.

Pressure Unit Conversion Table:

Unit Bar kPa PSI Kgf/cm²
Value 1 100 14.5 1.02

Note: Recommended tire pressure is usually indicated in Bar for vehicles.

To set the target tire pressure, first determine the desired pressure. The recommended (max) tire pressure can be found on the tire sidewall, vehicle sticker, or in the vehicle's manual. Adjust the target tire pressure using the "+"/"-" buttons. The set value will blink for 3 seconds, then the device will switch to real-time pressure monitoring mode.

Safety Warning: If the target pressure is not set and the air pump is turned on, it will not stop automatically. Manual shut-off is required. Failure to monitor tire pressure in real-time may lead to overinflation or tire damage.

Press and hold the "PUMP" button for 3 seconds to start the compressor. The compressor will automatically shut off when the tire pressure reaches the set value. To manually turn off the compressor, press the "PUMP" button or the power button ?.

Safety Warning: The product displays real-time tire pressure. A slight decrease in the displayed pressure after inflation is normal.

Remove the inflatable hose.

Safety Warning: The air compressor generates heat during inflation, causing the hose and all components to become hot. Allow the device to cool for 10 minutes before disconnecting the hose to prevent burns.

5. Error Codes

Error codes that may appear on the display:

Error Code Explanation Reason/Solution
? Overheating Protection Wait for the product to cool down.
❄️ Low Temperature Protection Use the product in an environment with suitable temperature.
Abnormal Fault Restart the product / contact professional service.
⚠️ Reverse Clamps Connect the clamps correctly to the battery.
330 Charging Reminder The device's current capacity is insufficient, please charge it.
430 External Battery Voltage Too High Set the correct air pressure.
450 Starting Failed Charge the device and try connecting to the battery again. This device is not intended for batteries with higher voltage, e.g., 24V. Check the correct connection and use the Emergency Start function.

6. Safety Precautions

Read the user manual carefully before using the device.

7. Preventive Measures and Further Instructions

8. Device Recycling

9. Warranty Conditions

In accordance with the provisions of § 2165 of the Civil Code (89/2012 Coll.), and Act No. 374/2022 Coll., the product is covered by a 24-month warranty against any material and workmanship defects.

Warranty claim conditions are as follows:

Batteries, as a component of the product, are manufactured in accordance with the Regulation of the European Parliament and of the Council (EU) 2023/1542 on batteries and waste batteries.

CE

Distributor:

www.battery-import.cz | www.solar-import.cz | www.battery-import.sk | www.battery.cz | www.efteria.cz

Efteria, spol. s r.o. | K Rybníku 378, 252 42 Jesenice, info@efteria.cz

IČ: 26763028 | DIČ: CZ26763028

PDF preview unavailable. Download the PDF instead.

ja301-pro navod k pouziti 2025-07 01 ?srsltid=AfmBOoqKrGybQZPdv268haYqO7W 4bvF iFQKDmTuGpSMbT8FuRl4tp5 Microsoft: Print To PDF

Related Documents

Preview LOKITHOR JA301: Portable Jump Starter and Air Compressor User Manual
This document provides comprehensive instructions for the LOKITHOR JA301 portable jump starter and 150PSI air compressor. It covers safety precautions, product overview, operating procedures for jump-starting, voltmeter function, and air inflation, along with error code explanations, warnings, recycling information, and warranty details.
Preview Lokithor J5000 PRO 12V Jump Starter User Manual
Comprehensive user manual for the Lokithor J5000 PRO 12V portable jump starter, covering safety instructions, features, specifications, operation, error codes, and warranty information.
Preview Lokithor JA301 2000A Jump Starter with Air Compressor - User Guide
Comprehensive guide for the Lokithor JA301, a 4-in-1 device featuring a 2000A peak jump starter, 150 PSI air compressor, LED flashlight, and power bank. Learn about its specifications, features, and operation for emergency car use.
Preview Lokithor JA301 Jump Starter and Air Inflator User Manual
Comprehensive guide for the Lokithor JA301, a 12V lithium jump starter with a 150 PSI air inflator. Learn about its features, operation, safety precautions, and troubleshooting.
Preview LOKITHOR Multi-function Vehicle Emergency Starter User Manual
Comprehensive user manual for the LOKITHOR multi-function vehicle emergency starter, covering jump-starting, air inflation, voltmeter, and LED light functions. Includes safety guidelines, operating procedures, and troubleshooting.
Preview LOKITHOR JA302 PRO Jump Starter User Manual
Comprehensive user manual for the LOKITHOR JA302 PRO jump starter, covering product description, technical specifications, package contents, usage instructions, error codes, safety precautions, and warranty information.
Preview Lokithor J3250 PRO 12V Jump Starter User Manual
Comprehensive guide to the Lokithor J3250 PRO 12V jump starter, covering safety instructions, features, specifications, operation, error codes, warnings, recycling, and warranty information.
Preview LOKITHOR JA300 Jump Starter and Air Compressor User Manual
Comprehensive user manual for the LOKITHOR JA300, a 1500Amp car battery booster and 150 PSI tire inflator. Learn how to jump-start vehicles, use the air compressor, voltmeter, and LED light functions.