GreenPerform Canopy Mini500 G4 Mounting Instruction

Model: BCP500 G4 Series

Document Version: 444170264661 V2

Technical Specifications

Type Desc Power (W) Voltage (V) Frequency (Hz) CCT Optics
BCP500 G4 LED85 PSU(PC) 53 2.8(2.6) 50/60 CW (Cool White), NW (Neutral White) Sym (Symmetric): S-MB/S-WB
Asym (Asymmetric): A-WB
BCP500 G4 LED125 PSU(PC) 79
BCP500 G4 LED140 PSU(PC) 91
BCP500 G4 LED180 PSU(PC) 122
BCP500 G4 LED85 PSD 58 7.3
BCP500 G4 LED125 PSD 85
BCP500 G4 LED140 PSD 96
BCP500 G4 LED180 PSD 128
BCP500 G4 LED85 GU5.3 53 6.7 50/60 CW (Cool White), NW (Neutral White) Sym (Symmetric): S-MB/S-WB
Asym (Asymmetric): A-WB
BCP500 G4 LED125 GU5.3 79
BCP500 G4 LED140 GU5.3 91
BCP500 G4 LED180 GU5.3 122

Dimensions:

  • BCP500 G4 LED 180&140&125&85 PSU (PC): Glass dimension 266x228x4 mm
  • BCP500 G4 LED 180&140&125&85 PSD: Glass dimension 328x239x4 mm
  • BCP500 G4 LED 180&140&125&85 GU5.3: Glass dimension 328x239x4 mm
Model Run current (A) @220V Start (inrush) current (A) / Ipeak (A) Start Current Duration (us) / T (@50% of Ipeak) (us) *Touch current or Protective conductor current (mA) Max. Num. of Luminaire on MCB16A Type B (pcs) Max. Num. of Luminaire on MCB16A Type C (pcs)
BCP500 G4 LED85 0.25 32.2 405 <1 8 14
BCP500 G4 LED125 0.375 32.2 405 <1 8 14
BCP500 G4 LED140 0.43 32.2 405 <1 8 14
BCP500 G4 LED180 0.565 32.2 405 <1 8 14

*The leakage current (touch current or protective conductor current) of electrical circuit may be greatly dependent upon electrical supply cables used such as its rating and length, proper connection of electrical supply cables to luminaires and wiring connection topology of luminaires to the supply electrical circuit amongst other site conditions. In some cases referred to as Earth Leakage Current.

Installation Instructions

1. Mounting Safety String

A safety cable can be mounted for this luminaire. The safety cable and fixing screws are not provided by Signify and must be arranged by a professional installer. The material specification for the safety cable should be robust and not less than SUS304 Ø3. The safety cable length should be a minimum of 'd' and a maximum of 'd + 30cm', where 'd' is the luminaire installation distance from the ceiling or mounting surface.

2. Predefine Luminaire Direction

Define the luminaire's direction before proceeding with the installation.

3. Fixing Surface Mounting Bracket

Secure the surface mounting bracket to the ceiling or mounting surface. This typically involves drilling holes and using appropriate screws. For example, use an M4x8 screw (1 pc) tightened to 1 N.m torque.

4. Fixing Luminaire

Attach the luminaire to the installed mounting bracket. Use the provided screws, for instance, an M4x8 screw (1 pc) tightened to 1 N.m torque.

Optional Accessory Installation: Frame Clamp (ZCB504)

1. Fixing Locking Ring on Mounting Bracket

Attach the frame clamp (locking ring) onto the mounting bracket using M5 screws (2 pcs) with 2 N.m torque.

2. Tighten Locking Ring to Post

Secure the locking ring to the post or mounting pole. Use M8 screws (2 pcs, M8x35) tightened to 8 N.m torque.

3. Fixing Luminaire on Mounting Bracket

Attach the luminaire to the mounting bracket using an M4x8 screw (1 pc) tightened to 1 N.m torque.

4. Proper Use of the Locking Ring

Illustrations show correct mounting orientations for the emitting surface: horizontally, aslant, and vertically.

Wiring Connections

PSU Version Wiring

Connect the power cable (220V-240V~ 50/60Hz) to the terminals: L (Brown wire), N (Blue wire), and Earth (Yellow/Green wire). Use cable type 60245 IEC57 3x1mm².

PSD Version Wiring

Connect the power cable (220V-240V~ 50/60Hz) to L (Brown), N (Blue), and Earth (Yellow/Green) terminals (60245 IEC57 3x1mm²). Connect the signal cable (DALI) to the designated terminals. For this version, basic insulation is maintained between the Low Voltage (LV) supply and control conductors.

GU5.3 Version Wiring

For the GU5.3 version, connect the power cable (220V-240V~ 50/60Hz) to L (Brown), N (Blue), and Earth (Yellow/Green) terminals (60245 IEC57 3x1mm²). For the 12V AC power supply, an external LED driver is required. This driver must be SELV (Safety Extra Low Voltage) with an output voltage (Uout) of 30Vdc or less, and must provide at least double insulation and reinforced insulation between the LV supply and the output.

Application Note (GU5.3 Version)

In the GU5.3 version, if the main luminaire fails to operate normally, the AC12V power supply will power the MR16 lamp to provide temporary lighting. The MR16 lamp is not included in the package.

Important Safety, Application, and Maintenance Information

Warnings

  • The luminaire must be installed by a qualified electrician in accordance with the latest IEE electrical regulations or national requirements.
  • Always turn off the power supply before checking, installation, or moving the luminaire.
  • External earthing is mandatory before use and must be maintained throughout the luminaire's life.
  • If any abnormalities or operational problems are found, switch off the power immediately and contact your nearest Signify dealer.
  • The luminaire must be used within the applicable product specifications, installation instructions, and environmental conditions as provided by Signify for the warranty to be valid.
  • Avoid corrosive atmospheres or hazardous materials such as sulfur, chlorine, and phthalates during use and storage.
  • The manufacturer is not responsible for damage caused by improper use or unauthorized modifications.
  • Luminaires must be used with their protective covers. Replace any cracked protective covers immediately.
  • Dispose of electrical and electronic products and packaging according to local regulations. Do not mix old products with household waste. Proper disposal helps prevent negative environmental and health consequences. Batteries should be disposed of separately via designated collection facilities. Non-user replaceable batteries must be removed by a professional.

Application Environment

  • For indoor use only.
  • Recommended height: Luminous surface to ground should be more than 2.5m; the bottom of the luminaire to the mounting surface must be more than 0.3m.
  • The luminaire is not designed with additional protection measures against high-altitude falling or wind loads, and cannot be used as a floodlight or tunnel luminaire.
  • Not suitable for use in environments with harsh vibration or frequent swinging. Also not suitable for areas prone to hurricanes or extreme winds.
  • Do not use this luminaire with a PC cover in environments that corrode PC materials, such as ethylamine or tetrachloroethylene.
  • This product contains a light source of energy efficiency class: D.

Maintenance

  • Periodic cleaning of the luminaire's optical lens cover is recommended to ensure maximum optical efficiency. Clean the luminaire only with a dry, soft cloth.
  • The light source, control gear, and external flexible cable contained within this luminaire shall only be replaced by the manufacturer, their service agent, or a similarly qualified person.
  • Do not use acid or alkaline cleaners on luminaires with PC covers.
  • If the toughened glass cover of the luminaire breaks, it must be replaced immediately.

Manufacturer Information

Signify (China) Investment Co., Ltd.
Address: Building 9 #, Lane 888, Tianlin Road, Minhang District, Shanghai City, P.R. China
Postal Code: 200233

Philips and the Philips shield emblem are registered trademarks of Koninklijke Philips N.V.

Models: BCP500 G4 LED85 PSU PC, BCP500 G4 LED125 PSU PC, BCP500 G4 LED140 PSU PC, BCP500 G4 LED180 PSU PC, BCP500 G4 LED85 PSD, BCP500 G4 LED125 PSD, BCP500 G4 LED140 PSD, BCP500 G4 LED180 PSD, BCP500 G4 LED85 GU5.3, BCP500 G4 LED125 GU5.3, BCP500 G4 LED140 GU5.3, BCP500 G4 LED180 GU5.3, Mini500 G4, Mini500 G4 Green Perform Canopy, Green Perform Canopy, Perform Canopy, Canopy

File Info : application/pdf, 6 Pages, 3.36MB

PDF preview unavailable. Download the PDF instead.

GreenPerform Canopy Mini500 G4

References

Microsoft: Print To PDF; modified using iTextSharp 5.0.2 (c) 1T3XT BVBA

Related Documents

Preview Philips GreenPerform Canopy Mini500 G4 LED Lighting - Product Specifications
Detailed product specifications for the Philips GreenPerform Canopy Mini500 G4 LED lighting system, including technical data, performance metrics, and physical dimensions. Ideal for food retail and general lighting applications.
Preview Philips BY570P GreenPerform Highbay Rectangular LED Lighting - Mounting Instructions
Comprehensive mounting instructions and technical specifications for the Philips BY570P GreenPerform Highbay Rectangular LED lighting. Includes installation guides, safety warnings, and electrical data.
Preview Philips CoreLine Highbay Gen 5 LED Luminaires - Technical Specifications and Installation Guide
Comprehensive guide to Philips CoreLine Highbay Gen 5 LED luminaires (BY120P, BY121P, BY122P), covering technical specifications, electrical characteristics, mounting options, wiring, safety, and installation guidelines.
Preview Philips GreenPerform Elite Highbay G2 BY778P Mounting Instructions
Comprehensive mounting instructions and technical specifications for the Philips GreenPerform Elite Highbay G2 LED Highbay, model BY778P. Includes installation guides, power connection details, safety warnings, and environmental compliance information.
Preview Philips GreenPerform Highbay G5 BY698P LED105/CW PSU NB GM L3m Product Datasheet
Detailed product datasheet for the Philips GreenPerform Highbay G5 (model BY698P G5 LED105/CW PSU NB GM L3m). This high-performance industrial luminaire offers leading system efficacy, Unified Glare Rating (UGR) control, and compatibility with IoT software like Interact. It is suitable for demanding industrial environments, including cold rooms, and features robust construction with an aluminium die-cast housing and polycarbonate lens.
Preview Philips GreenPerform Waterproof +5 WT178C Mounting Instruction
Comprehensive mounting instructions and technical specifications for the Philips GreenPerform Waterproof +5 WT178C LED luminaire. Details product features, dimensions, installation methods, cable connections, and inrush current data.
Preview GreenPerform Waterproof G2 WT188C LED Luminaire - Technical Data
Detailed specifications, features, and product information for the Philips GreenPerform Waterproof G2 WT188C LED luminaire, including performance data, dimensions, and ordering codes.
Preview Philips Coreline Highbay G5 LED Highbay Mounting Instructions
Comprehensive mounting instructions for the Philips Coreline Highbay G5 LED Highbay (BY698P G5) series, detailing installation procedures, safety warnings, and technical specifications for industrial LED lighting.