CLASS 120 KISTOCK DATA LOGGERS
KT120 / KH120 Quick Start Guide
Brand: Sauermann
Overview
The Sauermann KISTOCK KT120 and KH120 are data loggers designed for measuring and recording temperature and humidity.
Reference | Parameters |
---|---|
KT 120 | Temperature |
KH 120 | Temperature, humidity |
Operating Conditions, Storage, and Battery
- Operating Temperature: KT120: -40 to +70 °C; KH120: -20 to +70 °C
- Protection: KT120: IP65; KH120: IP20
- Storage Temperature: -40 to +85 °C
- Battery Power Supply: 1 x CR2450 button battery
Display
The device features a digital display with various indicators:
- END: Indicates the dataset is finished.
- REC (flashing): Indicates a value is being recorded; flashing means the dataset has not yet started.
- Storage Capacity Indicators:
- Slowly flashing: Dataset is between 80% and 90% of storage capacity.
- Quickly flashing: Dataset is between 90% and 100% of storage capacity.
- Constant: Storage capacity is full.
- Max/Min Values: The displayed values are the recorded maximum/minimum values for the displayed channels.
- Alarm Indicator: Indicates the alarm action type (rising or falling action).
- BAT (constant): Indicates that the batteries have to be replaced.
- Channel Number: Indicates the channel number which is measuring.
Units displayed can be: °C (Celsius), °F (Fahrenheit), %RH (Relative humidity for KH 120).
Dimensions (mm)
The device has the following approximate dimensions:
- Height: ~100 mm
- Width: ~42.5 mm
- Depth: ~15.9 mm
[Diagram Description: A technical drawing showing the external dimensions of the data logger from three different angles.]
Connections
The device connects to a PC via a USB port.
[Diagram Description: A close-up view of the device's USB connection port, showing a male USB connector and an integrated protection cap.]
Recorder Function
The KISTOCK allows recording measured values instantaneously at a predefined interval, or continuously via loop recording.
Dataset Start Types:
- Delayed start (with predefined date and time).
- Start via software.
- Start via push-button.
Dataset Stop Types:
- According to a predefined date and time (if started the same way).
- According to a recording duration.
- According to a predefined number of recording points.
- When storage capacity is full.
- Via the "Stop" option in the software.
- By holding the "OK" key for approximately 5 seconds (if previously activated by software).
Mounting
The KISTOCK data loggers feature magnetic mounting for easy installation.
[Diagram Description: The back of the data logger showing mounting points: 1. Magnetic mounting, 2. Battery cover, 3. Locking sign of the battery cover.]
Battery Replacement
With a battery life of 500 days to 3 years, KISTOCK devices ensure long-term measurements.
To replace the battery:
- Unlock the battery cover using a screwdriver or coin.
- Insert a new CR2450 button battery with the positive (+) pole visible.
- Replace the battery cover, aligning the indicator with the padlock symbol (turn right to lock).
Note: Batteries must comply with the IEC 60086-4 standard.
Accessories
Refer to the data sheet for more information on available accessories.
Maintenance and Precautions
- Maintenance: Avoid aggressive solvents. Protect the device from formalin-based cleaning products when cleaning surfaces (rooms, ducts).
- Precautions for Use: Always use the device in accordance with its intended use and within the parameters described in the technical features to ensure the device's protection.