CLASS 120 KISTOCK DATA LOGGERS
KT120 / KH120 Quick Start Guide
Specifications
Reference | Parameters |
---|---|
KT 120 | Temperature |
KH 120 | Temperature, humidity |
Operating Conditions:
- Operating temperature: KT120: -40 to +70 °C; KH120: -20 to +70 °C
- Protection: KT120: IP65; KH120: IP20
- Storage temperature: -20 to +50 °C
- Battery power supply: 1 x CR2450 (button battery)
1. Display Indicators
The Kistock data loggers feature several indicators:
- [REC]: Indicates that a value is being recorded. Flashing indicates the dataset has not started.
- [END]: Indicates that the dataset is finished.
- [FULL]: Constant display indicates storage capacity is full. Slow flashing indicates 80-90% capacity used; fast flashing indicates 90-100% capacity used.
- Displayed Values: Show recorded maximum/minimum values for the displayed channels.
- [BAT]: Indicates that the batteries need to be replaced (often accompanied by a flashing screen or LED).
- Alarm Indicator: Shows alarm action type (rising or falling action).
- Channel Number: Indicates the channel currently measuring (e.g., '12').
- Temperature Units: °C (Celsius), °F (Fahrenheit).
- Humidity Unit: %RH (Relative humidity for KH 120).
2. Dimensions
The Kistock data loggers have the following approximate dimensions:
- Height: ~100 mm
- Width: ~42.5 mm
- Depth: ~15.9 mm
[Diagram showing the three-view drawing of the data logger with dimensions]
3. Connections
The device connects to a PC via a USB port.
[Diagram showing the data logger with a USB cable connected to a PC, labeling the 'Male USB connector' and 'Integrated protection cap']
5. Recorder Function
The KISTOCK data loggers record measured values instantaneously or at predefined intervals. Loop recording is also supported for continuous operation.
Dataset Start Methods:
- Delayed start (with predefined date and time)
- Via the software
- Via push-button
Dataset Stop Methods:
- By date and time (if started similarly)
- By recording duration
- By a predefined number of recording points
- When storage capacity is full
- Via the software "Stop" option
- By holding the "OK" key for approximately 5 seconds (if previously activated by software)
6. Mounting
The KISTOCK data loggers feature magnetic mounting for easy installation.
- 1. Magnetic mounting
- 2. Battery cover
- 3. Locking sign of the battery cover
[Diagram showing the back of the data logger with numbered mounting points]
7. Battery Replacement
With a battery life of 500 days to 3 years, KISTOCK devices ensure long-term measurements.
To replace the battery:
- Unlock the battery cover using a screwdriver or coin.
- Insert a new CR2450 button battery with the positive (+) pole visible.
- Replace the battery cover, aligning the indicator with the open padlock symbol, and turn it clockwise to the closed padlock position.
⚠️ Note: The battery must comply with the IEC 60086-4 standard.
8. Accessories
Refer to the datasheet for more information on available accessories.
Maintenance:
Avoid aggressive solvents. Protect the device from cleaning products containing formalin, which may be used in clean rooms or ducts.
Precautions for Use:
Always use the device in accordance with its intended use and within the parameters described in the technical features to ensure the device's protection is not compromised.