DAMPPROOF COMBO
Brand: LEDVANCE
Product Overview
The LEDVANCE DAMPPROOF COMBO is a series of robust, energy-efficient luminaires designed for demanding environments. These fixtures offer high performance, flexibility, and durability, suitable for various industrial, commercial, and public applications where protection against dust and moisture is required.
Technical Specifications
General Specifications
Model | EAN | Dimensions (L x W x H) [mm] | Wattage (W) | Lumens (lm) | Lumens per Watt (lm/W) | IP Rating | IK Rating | Ambient Temperature (°C) |
---|---|---|---|---|---|---|---|---|
DAMPPROOF COMBO 600 | 4099854521355 | 670 x 97 x 78 | 8, 11, 13, 16 | 1220, 1670, 1960, 2400 | 150 | 66 | 10 | -20...+40 |
DAMPPROOF COMBO 1200 | 4099854521379 | 1270 x 97 x 78 | 16, 21, 26, 32 | 2450, 3190, 3920, 4800 | 150 | 66 | 10 | -20...+40 |
DAMPPROOF COMBO 1500 | 4099854521393 | 1570 x 97 x 78 | 25, 33, 42 | 3820, 5010, 6340 | 150 | 66 | 10 | -20...+40 |
DAMPPROOF COMBO 1800 | 4099854521416 | 1870 x 97 x 78 | 30, 40, 50, 60 | 4590, 6080, 7550, 9000 | 150 | 66 | 10 | -20...+40 |
Electrical and Performance Specifications
Model | EAN | Voltage (VAC) | Frequency (Hz) | Power Factor (PF) | Color Rendering Index (Ra) | Weight (kg) |
---|---|---|---|---|---|---|
DAMPPROOF COMBO 600 | 4099854521355 | 220-240V | 50/60 Hz | >0.7 | ≥80 | 0.80 kg |
DAMPPROOF COMBO 1200 | 4099854521379 | 220-240V | 50/60 Hz | >0.9 | ≥80 | 1.43 kg |
DAMPPROOF COMBO 1500 | 4099854521393 | 220-240V | 50/60 Hz | >0.9 | ≥80 | 1.73 kg |
DAMPPROOF COMBO 1800 | 4099854521416 | 220-240V | 50/60 Hz | >0.9 | ≥80 | 2.12 kg |
Circuit Breaker Recommendations
Model | B16 | B10 | C16 | C10 |
---|---|---|---|---|
DAMPPROOF COMBO 600 | n=40 | n=25 | n=40 | n=25 |
DAMPPROOF COMBO 1200 | n=42 | n=25 | n=42 | n=25 |
DAMPPROOF COMBO 1500 | n=22 | n=12 | n=36 | n=22 |
DAMPPROOF COMBO 1800 | n=16 | n=10 | n=28 | n=16 |
Accessories
Batten Combo Sensor
EAN: 4099854521461
Dimensions: 82 x 44 x 35 mm
Weight: 40g
Diagram shows a compact sensor unit with connection terminals.
Emergency CG Unit
EAN: 4099854521430
Dimensions: 217 x 44 x 31mm
Weight: 218g
Diagram shows an emergency lighting module and associated components, including screws.
CG Battery
EAN: 4099854521515
Dimensions: 66.5 x 37 x 20 mm
Weight: 88g
Diagram shows a cylindrical battery pack.
Operational Modes and Settings
Functionality Modes
- Maintained (1): Luminaire operates continuously.
- Non-maintained (2): Luminaire operates only during power failure (emergency mode).
Diagram 5 illustrates wiring for Maintained and Non-maintained modes.
Test Modes
- Self test mode (7): The luminaire automatically performs periodic self-checks.
- Manual test mode (8): Allows for manual activation of test sequences.
Diagram 14 illustrates the Self test mode and Manual test mode indicators.
Switch Settings (SW1, SW2)
SW1: Controls lumen output (lm) and wattage for maintained/non-maintained operation.
SW2: Controls color temperature (K).
Diagram 6 shows the switch configurations for different lumen outputs (2400lm to 9000lm) and color temperatures (6500K, 4000K) for various DAMPPROOF COMBO models.
Installation Guide
Follow these steps for installation:
- Safety First: Ensure the power supply is switched OFF at the main breaker before starting any installation work. A warning symbol ⚠️ and electrical hazard symbol ⚡ are displayed.
Diagram 1 shows a hand turning a switch to the OFF position.
- Mounting Dimensions: Refer to Diagram 2 for specific X and Y mounting dimensions for each DAMPPROOF COMBO model (600, 1200, 1500, 1800).
Diagram 2 presents a table of mounting dimensions (X, Y) for different models.
- Bracket Installation: Secure the mounting brackets to the ceiling or surface using appropriate screws and wall plugs. Arrows indicate upward installation.
Diagram 3a shows mounting brackets, screws, and wall plugs being installed.
- Luminaire Attachment: Attach the luminaire body to the installed brackets.
Diagram 3b shows mounting brackets being attached to the luminaire body.
- Opening Luminaire: Open the luminaire housing, typically by releasing latches or clips.
Diagram 4 shows a luminaire cover being opened by pressing down until it clicks twice.
- Wiring: Connect the power supply wires (Live, Neutral, Earth) according to the selected mode (Maintained or Non-maintained).
Diagram 5 illustrates the wiring connections for Maintained and Non-maintained operation.
- Sensor/Emergency Unit Installation (if applicable): Install optional accessories like the Batten Combo Sensor or Emergency CG unit. Connect them to the designated terminals.
Diagrams 7, 8, 9, 11, 16, and 17 show the installation and connection of sensors and emergency units.
- Configure Switches: Set the internal switches (SW1, SW2) to select the desired lumen output and color temperature.
Diagram 6 details the switch settings for lumen output and color temperature.
- Closing Luminaire: Securely close the luminaire housing, ensuring all covers and latches are properly engaged.
Diagrams 10, 12, 18 show the process of closing and securing the luminaire covers, often with an audible "click".
- Testing: Perform functional tests, including self-test or manual test modes if applicable.
Diagram 14 explains the Self test mode and Manual test mode.
- Final Power Up: Restore power to the luminaire.
Diagram 19 reiterates the power-on step after installation.
Certifications and Compliance
The product bears various certification marks, including CE, UKCA, and EAC, indicating compliance with relevant standards. Recycling instructions are also provided, suggesting disposal according to local regulations.
Page 8 displays various certification logos and recycling symbols.