The LEDVANCE DAMPPROOF COMBO is a series of robust, energy-efficient luminaires designed for demanding environments. These fixtures offer high performance, flexibility, and durability, suitable for various industrial, commercial, and public applications where protection against dust and moisture is required.

Technical Specifications

General Specifications

ModelEANDimensions (L x W x H) [mm]Wattage (W)Lumens (lm)Lumens per Watt (lm/W)IP RatingIK RatingAmbient Temperature (°C)
DAMPPROOF COMBO 6004099854521355670 x 97 x 788, 11, 13, 161220, 1670, 1960, 24001506610-20...+40
DAMPPROOF COMBO 120040998545213791270 x 97 x 7816, 21, 26, 322450, 3190, 3920, 48001506610-20...+40
DAMPPROOF COMBO 150040998545213931570 x 97 x 7825, 33, 423820, 5010, 63401506610-20...+40
DAMPPROOF COMBO 180040998545214161870 x 97 x 7830, 40, 50, 604590, 6080, 7550, 90001506610-20...+40

Electrical and Performance Specifications

ModelEANVoltage (VAC)Frequency (Hz)Power Factor (PF)Color Rendering Index (Ra)Weight (kg)
DAMPPROOF COMBO 6004099854521355220-240V50/60 Hz>0.7≥800.80 kg
DAMPPROOF COMBO 12004099854521379220-240V50/60 Hz>0.9≥801.43 kg
DAMPPROOF COMBO 15004099854521393220-240V50/60 Hz>0.9≥801.73 kg
DAMPPROOF COMBO 18004099854521416220-240V50/60 Hz>0.9≥802.12 kg

Circuit Breaker Recommendations

ModelB16B10C16C10
DAMPPROOF COMBO 600n=40n=25n=40n=25
DAMPPROOF COMBO 1200n=42n=25n=42n=25
DAMPPROOF COMBO 1500n=22n=12n=36n=22
DAMPPROOF COMBO 1800n=16n=10n=28n=16

Accessories

Batten Combo Sensor

EAN: 4099854521461

Dimensions: 82 x 44 x 35 mm

Weight: 40g

Diagram shows a compact sensor unit with connection terminals.

Emergency CG Unit

EAN: 4099854521430

Dimensions: 217 x 44 x 31mm

Weight: 218g

Diagram shows an emergency lighting module and associated components, including screws.

CG Battery

EAN: 4099854521515

Dimensions: 66.5 x 37 x 20 mm

Weight: 88g

Diagram shows a cylindrical battery pack.

Operational Modes and Settings

Functionality Modes

Diagram 5 illustrates wiring for Maintained and Non-maintained modes.

Test Modes

Diagram 14 illustrates the Self test mode and Manual test mode indicators.

Switch Settings (SW1, SW2)

SW1: Controls lumen output (lm) and wattage for maintained/non-maintained operation.

SW2: Controls color temperature (K).

Diagram 6 shows the switch configurations for different lumen outputs (2400lm to 9000lm) and color temperatures (6500K, 4000K) for various DAMPPROOF COMBO models.

Installation Guide

Follow these steps for installation:

  1. Safety First: Ensure the power supply is switched OFF at the main breaker before starting any installation work. A warning symbol ⚠️ and electrical hazard symbol ⚡ are displayed.

    Diagram 1 shows a hand turning a switch to the OFF position.

  2. Mounting Dimensions: Refer to Diagram 2 for specific X and Y mounting dimensions for each DAMPPROOF COMBO model (600, 1200, 1500, 1800).

    Diagram 2 presents a table of mounting dimensions (X, Y) for different models.

  3. Bracket Installation: Secure the mounting brackets to the ceiling or surface using appropriate screws and wall plugs. Arrows indicate upward installation.

    Diagram 3a shows mounting brackets, screws, and wall plugs being installed.

  4. Luminaire Attachment: Attach the luminaire body to the installed brackets.

    Diagram 3b shows mounting brackets being attached to the luminaire body.

  5. Opening Luminaire: Open the luminaire housing, typically by releasing latches or clips.

    Diagram 4 shows a luminaire cover being opened by pressing down until it clicks twice.

  6. Wiring: Connect the power supply wires (Live, Neutral, Earth) according to the selected mode (Maintained or Non-maintained).

    Diagram 5 illustrates the wiring connections for Maintained and Non-maintained operation.

  7. Sensor/Emergency Unit Installation (if applicable): Install optional accessories like the Batten Combo Sensor or Emergency CG unit. Connect them to the designated terminals.

    Diagrams 7, 8, 9, 11, 16, and 17 show the installation and connection of sensors and emergency units.

  8. Configure Switches: Set the internal switches (SW1, SW2) to select the desired lumen output and color temperature.

    Diagram 6 details the switch settings for lumen output and color temperature.

  9. Closing Luminaire: Securely close the luminaire housing, ensuring all covers and latches are properly engaged.

    Diagrams 10, 12, 18 show the process of closing and securing the luminaire covers, often with an audible "click".

  10. Testing: Perform functional tests, including self-test or manual test modes if applicable.

    Diagram 14 explains the Self test mode and Manual test mode.

  11. Final Power Up: Restore power to the luminaire.

    Diagram 19 reiterates the power-on step after installation.

Certifications and Compliance

The product bears various certification marks, including CE, UKCA, and EAC, indicating compliance with relevant standards. Recycling instructions are also provided, suggesting disposal according to local regulations.

Page 8 displays various certification logos and recycling symbols.

PDF preview unavailable. Download the PDF instead.

elosos1915936 Adobe InDesign 20.2 (Macintosh) GPL Ghostscript 9.55.0

Related Documents

Preview LEDVANCE DAMP PROOF MAX Series - Product Specifications and Installation Guide
Detailed product information and installation guide for the LEDVANCE DAMP PROOF MAX series of robust, damp-proof LED luminaires. Includes specifications, assembly steps, and testing procedures.
Preview LEDVANCE LED Luminaires: Advancing Light for Every Application
Explore the comprehensive LED luminaire portfolio from LEDVANCE, designed to enhance concentration, well-being, and efficiency across various sectors including industry, office, shop, and hospitality. Discover innovative lighting solutions with a focus on aesthetic, individual, and functional design.
Preview LEDVANCE FLOODLIGHT AREA GEN 2: Efficient, Bright Outdoor Lighting
Discover the LEDVANCE FLOODLIGHT AREA GEN 2, engineered for performance and durability. This range offers efficient, bright, and glare-free illumination for logistics centers, industrial areas, car parks, and sports facilities, with features like multi-lumen functionality and robust, weather-resistant design.
Preview LEDVANCE EMERGENCY SPOT E 1.3W 3H AT - Technical Data and Installation Guide
Comprehensive technical specifications, installation instructions, and testing procedures for the LEDVANCE EMERGENCY SPOT E 1.3W 3H AT emergency lighting fixture.
Preview LEDVANCE LED Luminaires Portfolio Summer 2025 | Innovative Lighting Solutions
Discover the extensive LEDVANCE LED Luminaires Portfolio for Summer 2025. This catalog features advanced lighting solutions for various applications, emphasizing innovation, sustainability, and energy efficiency. Find the perfect LED luminaires for your projects.
Preview LEDVANCE MULTI SELECT Luminaires: Versatile and Efficient Lighting Solutions
Explore the LEDVANCE MULTI SELECT range of luminaires, offering selectable multi-lumen and multi-color options for various applications. Discover efficient, sustainable, and high-performance lighting solutions for businesses.
Preview Endura Flood Solar Double Sensor LED Lighting - Installation and Operation Guide
Detailed guide for the LEDVANCE Endura Flood Solar Double Sensor, covering installation, operation modes, and specifications. Features solar power, motion sensing, and adjustable lighting.
Preview LEDVANCE SMART+ Πρόγραμμα 2020/2021: Έξυπνος Φωτισμός για το Σπίτι
Ανακαλύψτε τη σειρά SMART+ της LEDVANCE για έξυπνο φωτισμό σπιτιού. Εξερευνήστε λύσεις WIFI, Bluetooth και Zigbee για έλεγχο μέσω smartphone, φωνής ή πύλης, με δυνατότητες αυτοματισμού και δημιουργίας ατμόσφαιρας.