Honeywell BW™ Flex Series Portable Multiple Gas Detector
Quick Reference Guide
Introduction
The Honeywell BW™ Flex gas detector warns of hazardous gas at levels above user-defined alarm setpoints. The detector can monitor up to four gases at a time. Refer to the Honeywell BW™ Flex Series User Manual for the full list of gases.
Safety Precautions
- CAUTION: The detector is a personal safety device. It is your responsibility to respond properly to the alarm.
- For safety reasons, this equipment must be operated and serviced by qualified personnel only.
- The Li-ion battery in this product presents a risk of fire, explosion, and chemical burn if misused. Do not disassemble, incinerate, or heat above 212°F (100°C). Batteries exposed to heat at 266°F (130°C) for 10 minutes can cause fire and explosion. Batteries must only be charged in a safe area free of hazardous gas.
- Deactivating the detector by removing the battery pack may cause improper operation and harm the detector.
- Use only Honeywell approved battery chargers such as the vehicle Charger.
- Do not use the apparatus if it is damaged. Inspect the apparatus before use. Look for cracks and missing parts.
Basic Device Operations
Power On: 4-second hold
Power Off: 4-second hold
Enter Menu: Double-press
Exit Menu: 3-second Hold
Select Next: Single-press
Initiate Selected: 3-second Hold
Acknowledge latched alarm: 1-second hold
Bump Test and Calibration via a Mobile Device
- Turn On the BW Flex. Place the cap over the detector, and then press down on both tabs to snap it into place.
- In your mobile device, open the Device Configurator app.
- Attach the hose.
- In the Device List screen, select the BW Flex Serial Number to start pairing. The upper LED will light green after pairing succeed.
- Follow on-screen instructions in the app (Tap on the Menu button, Select Remote Calibration or Bump Test).
- The process is complete when the results are displayed on your mobile device. You can now remove the cap by pulling on the tabs.
What’s in the Box
- Honeywell BW™ Flex gas detector
- Battery (factory-installed)
- USB charger
- 1 Calibration cap
- Tubing
- 1 Klick Fast stud
- Quick Reference Guide
Device Components
- 1 LED Alarm: Visual indicator for alarms.
- 2 IntelliFlash: Indicator light for device status.
- 3 Display: Shows readings and status information.
- 4 Button: Used for device operation and navigation.
- 5 Beeper: Audible alarm indicator.
- 6 Sensor: Detects specific gases.
- 7 Clip: For attaching the detector to clothing or equipment.
- 8 Battery: Provides power to the device.
- 9 Charging Port: For charging the device battery.
Safety Certifications
IECEx: IECEx SIR 20.0020X
- With IR sensor installed: Ex ia op is I Ma Ex ia op is IIC T4 Ga, -40°C≤ Tamb ≤ 60°C
- With LEL sensor installed: Ex da ia I Ma Ex da ia IIC T4 Ga, -40°C≤ Tamb ≤ 60°C
- With IR and LEL sensor installed: Ex da ia op is I Ma Ex da ia op is IIC T4 Ga, -40°C≤ Tamb ≤ 60°C
- Without IR and LEL sensor installed: Ex ia I Ma Ex ia IIC T4 Ga, -40°C≤ Tamb ≤ 60°C
ATEX: Sira 20ATEX2012X
- With IR sensor installed: I M1 Ex ia op is I Ma, -40°C≤ Tamb ≤ 60°C II 1G Ex ia op is IIC T4 Ga, -40°C≤ Tamb ≤ 60°C
- With LEL sensor installed: I M1 Ex da ia I Ma, -40°C≤ Tamb ≤ 60°C II 1G Ex da ia IIC T4 Ga, -40°C≤ Tamb ≤ 60°C
- With IR and LEL sensor installed: I M1 Ex da ia op is I Ma, -40°C≤ Tamb ≤ 60°C II 1G Ex da ia op is IIC T4 Ga, -40°C≤ Tamb ≤ 60°C
- Without IR and LEL sensor installed: I M1 Ex ia I Ma, -40°C≤ Tamb ≤ 60°C II 1G Ex ia IIC T4 Ga, -40°C≤ Tamb ≤ 60°C
RED: RED Directive 2014/53/EU
EMC: Directive 2014/30/EU
ROHS: Directive (EU) 2015/863 amending 2011/65/EU
IP: IP66, IP68 (1.2 meters for 45 minutes)
Contact Information
Europe, Middle East, Africa
Life Safety Distribution GmbH
Toll-Free: 00800 333 222 44
Middle East: +971 4 450 5800 / +971 4 450 5852
Email: gasdetection@honeywell.com
Americas
Honeywell Analytics Distribution Inc.
Tel: +1 847 955 8200
Toll free: +1 800 538 0363
Email: detectgas@honeywell.com
Asia Pacific
Honeywell Analytics Asia Pacific
Tel: +82 (0) 2 6909 0300
India Tel: +91 124 4752700
Email: analytics.ap@honeywell.com
Technical Services
EMEA: HAexpert@honeywell.com
US: ha.us.service@honeywell.com
AP: ha.ap.service@honeywell.com
Website: www.honeywellanalytics.com