Honeywell BW™ Flex Series Portable Multiple Gas Detector

Quick Reference Guide

Introduction

The Honeywell BW™ Flex gas detector warns of hazardous gas at levels above user-defined alarm setpoints. The detector can monitor up to four gases at a time. Refer to the Honeywell BW™ Flex Series User Manual for the full list of gases.

Safety Precautions

Basic Device Operations

Power On: 4-second hold

Power Off: 4-second hold

Enter Menu: Double-press

Exit Menu: 3-second Hold

Select Next: Single-press

Initiate Selected: 3-second Hold

Acknowledge latched alarm: 1-second hold

Bump Test and Calibration via a Mobile Device

  1. Turn On the BW Flex. Place the cap over the detector, and then press down on both tabs to snap it into place.
  2. In your mobile device, open the Device Configurator app.
  3. Attach the hose.
  4. In the Device List screen, select the BW Flex Serial Number to start pairing. The upper LED will light green after pairing succeed.
  5. Follow on-screen instructions in the app (Tap on the Menu button, Select Remote Calibration or Bump Test).
  6. The process is complete when the results are displayed on your mobile device. You can now remove the cap by pulling on the tabs.

What’s in the Box

Device Components

Safety Certifications

IECEx: IECEx SIR 20.0020X

ATEX: Sira 20ATEX2012X

RED: RED Directive 2014/53/EU

EMC: Directive 2014/30/EU

ROHS: Directive (EU) 2015/863 amending 2011/65/EU

IP: IP66, IP68 (1.2 meters for 45 minutes)

Contact Information

Europe, Middle East, Africa
Life Safety Distribution GmbH
Toll-Free: 00800 333 222 44
Middle East: +971 4 450 5800 / +971 4 450 5852
Email: gasdetection@honeywell.com

Americas
Honeywell Analytics Distribution Inc.
Tel: +1 847 955 8200
Toll free: +1 800 538 0363
Email: detectgas@honeywell.com

Asia Pacific
Honeywell Analytics Asia Pacific
Tel: +82 (0) 2 6909 0300
India Tel: +91 124 4752700
Email: analytics.ap@honeywell.com

Technical Services
EMEA: HAexpert@honeywell.com
US: ha.us.service@honeywell.com
AP: ha.ap.service@honeywell.com

Website: www.honeywellanalytics.com

Models: BW Flex Series, Portable Multiple Gas Detector

File Info : application/pdf, 2 Pages, 5.84MB

PDF preview unavailable. Download the PDF instead.

sps-his-m05-4002-001-bw-flex-multilingual-qrg Adobe PDF Library 15.0 Adobe InDesign 15.1 (Windows)

Related Documents

Preview Honeywell BW™ Icon & BW™ Icon+ Portable Gas Detector Quick Reference Guide
A quick reference guide for operating, testing, and calibrating the Honeywell BW™ Icon and BW™ Icon+ portable gas detectors, covering device setup, user interface, common operations, and safety information.
Preview Honeywell BW Ultra Gas Detector: Quick Reference Guide & Safety
Get essential information on the Honeywell BW Ultra portable gas detector. This quick reference guide covers setup, safety precautions, operation, and alarms for reliable gas detection.
Preview Honeywell BW RigRat Quick Start Guide: Operation, Charging, and Calibration
A concise guide to operating, charging, performing bump tests, and calibrating the Honeywell BW RigRat portable gas detector. Includes basic navigation and app information.
Preview Honeywell BW™ Icon & BW™ Icon + Portable Gas Detector User Manual
User manual for Honeywell BW™ Icon and BW™ Icon + portable multiple gas detectors. This guide details product features, safety, operations, maintenance, and specifications for hazardous gas detection.
Preview Honeywell BWTM Ultra Portable Gas Detector User Manual - Operation, Maintenance, Safety
Detailed user manual for the Honeywell BWTM Ultra portable multi-gas detector. Covers setup, calibration, bump testing, maintenance, sensor replacement, troubleshooting, and safety guidelines for industrial gas monitoring.
Preview Honeywell BW™ Flex 4 Multi-Gas Monitor Quick Reference Guide
Quick reference guide for the Honeywell BW™ Flex 4 Multi-Gas Monitor, covering general warnings, operation, maintenance, specifications, certifications, and contact information.
Preview Honeywell BW™ Ultra Portable Five-gas Detector User Manual
Comprehensive user manual for the Honeywell BW™ Ultra portable five-gas detector with internal pump, covering safety, operation, maintenance, and troubleshooting.
Preview Honeywell IntelliDoX Docking Module Quick Reference Guide
Quick reference guide for setting up and operating the Honeywell IntelliDoX Docking Module for automatic bump testing and calibration of portable gas detectors. Includes setup, connection, charging, bump test, and calibration procedures.