INKBIRD IHC-200 WIFI Humidity Controller
Part 1: Quick Guide to Use
01 CAUTION
ATTENTION:
- KEEP CHILDREN AWAY
- TO REDUCE THE RISK OF ELECTRIC SHOCK, USE ONLY INDOORS
- RISK OF ELECTRIC SHOCK. DO NOT PLUG INTO ANOTHER RELOCATABLE POWER TAPS OR AN EXTENSION CORD.
- USE ONLY IN DRY LOCATION
ATTENTION (French):
- ELOGIGANEZ LES ENFANTS
- Pour réduire le d'électrocution, Pour Usage À L'Intérieur Seulement.
- Risque de choc électrique. Ne pas brancher dans une autresource de courant portative ou une rallonge.
- UTILISER UNIQUEMENT DANS DES EMPLACEMENTS SECS
02 Specification
Model: IHC-200-WIFI
Brand name: INKBIRD
Input: 230V ac 50Hz 10A/2300W MAX
Output: 230V ac 50Hz 10A/2300W (total two receptacles) MAX
Disconnection means: Type 1B
Pollution degree: 2
Rated impulse voltage: 2500V
Automatic action: 30000 cycles
Humidity Probe
Humidity Measurement Range: 10~99%RH
Humidity Display Accuracy: 0.1%RH
Relative Humidity Accuracy (10% to 95%RH): Type: ±3%RH, Max: ±5%RH
Display Unit: %RH
Ambient
Ambient temperature: Room temperature
Storage environment: temperature:0°C~60°C/32°F~140°F; humidity: 20~80%RH (Unfrozen or condensation state)
Warranty
Controller: Two years warranty
Temperature and Humidity Probe: One year warranty
03 Technical Assistance and Warranty
3.1 Technical Assistance
For installation or usage problems, refer to the instruction manual. For further assistance, email support@inkbird.com. Replies are provided within 24 hours, Monday to Saturday. Visit the official website (www.inkbird.com) for common technical questions.
3.2 Warranty
INKBIRD TECH CO., LTD warrants this controller for one year (temperature probe) and two years (controller) against defects in workmanship or materials from the date of purchase, provided it is operated under normal conditions by the original purchaser (non-transferable). This warranty is limited to repair or replacement at INKBIRD's discretion.
Part 2: Wi-Fi Humidity Controller Manual
01 Introduction
The IHC-200 WIFI Humidity Controller features:
- PV (1): Displays current humidity in normal mode; displays menu code in setting mode.
- SV (2): Displays the setting humidity value in normal mode; displays the setting value in setting mode.
- Red Indicator Light (3): Indicates humidification output is ON (red) or OFF.
- Green Indicator Light (4/5): Indicates dehumidification output is ON (green) or OFF. Blinking green indicates dehumidification delay protection state.
- WORK1 (6): Humidification Output Socket.
- WORK2 (7): Dehumidification Output Socket.
- Buttons (8): Setting Button (SET), Increase Button (▲), Decrease Button (▼) for settings.
02 Product Features
- Plug-n-Play
- Dual Relay Output: Supports both humidifying and dehumidifying equipment simultaneously.
- Display Screens: Show set humidity value and measured humidity value concurrently.
- Support Humidity Calibration
- Support Dehumidification Control Delay Protection
- Settable High/Low Humidity Alarm
- Probe Fault Alarm
- Wi-Fi Smart App
03 Specifications
- Voltage: 100-230Vac 50/60Hz
- Current: 10A
- Maximum Power: 1200W(120Vac), 2200W(220Vac)
- Humidity Measurement Range: 10~99%RH
- Humidity Display Accuracy: 0.1%RH
- Relative Humidity Accuracy (10% to 95%RH): Typ: ±3%RH, Max: ±5%RH
- Display Unit: %RH
- Operating Ambient Temperature: -20℃~40℃/-4°F~104°F
- Storage Temperature: 0°C~60°C/32°F~140°F
- Storage Humidity: 20~80%RH (not frozen or dewed)
- Warranty: Controller: 2 years, Probe: 1 year
04 Wi-Fi Connection
4.1 Download INKBIRD App
Search for "INKBIRD" on the Appstore or Google Play to download the app. Alternatively, scan the provided QR code.
[QR code for INKBIRD APP download]
4.2 Connect to your phone
- Register using the INKBIRD app by selecting your Country/Region and entering your email. A verification code will be sent to your mailbox for identity confirmation.
- Press the "Add Home" button to create your home.
- Tap "+" or "add device" on the home page to add the device.
- To reset the WIFI, press and hold the [WIFI] button for 2 seconds. The controller enters Smartconfig configuration state by default. Short press the [WIFI] button to switch between Smartconfig and AP modes.
The WIFI module requires approximately 5 seconds for data processing to display the corresponding LED symbol and Wi-Fi status.
4.3 Quick Connection
- Plug the device into the socket and ensure it is in Smartconfig state (LED symbol flashing rapidly, interval 250ms).
- Check if the LED symbol is blinking rapidly and confirm on the app. Enter your Wi-Fi password and click "Confirm" to connect.
Note: The device supports only 2.4GHz Wi-Fi routers.
4.4 Connect the device in AP mode
- Plug the device into the socket and ensure it is in AP Configuration State (LED symbol flashing slowly, interval 1500ms).
- Click "Confirm indicator slowly blink" and select your Wi-Fi network. Enter the Wi-Fi password and click "Confirm" to proceed.
- Press "Connect now" to access your smartphone's WLAN Setting interface. Select "SmartLife-XXXX" to connect directly to the router without a password.
- Return to the app to enter the automatic connection interface.
- Click "Done" after successful device addition to enter the device controlling interface.
- In humidity control mode, users can configure control functions via the app.
4.5 Wi-Fi State
- Smartconfig State: Wi-Fi indicator light flashes rapidly (250ms interval).
- AP State: Wi-Fi indicator light flashes slowly (1500ms interval).
- Connection Fail State: Wi-Fi indicator light is off.
- Connection Succeed State: Wi-Fi indicator light remains on.
05 Settings
5.1 Key Setting
5.1.1 Factory Reset
Hold the [SET] button and turn on the device. A short beep indicates that all humidity probe parameters have been restored to factory settings.
5.1.2 Fast Setting
Press the [SET] button lightly to enter quick set-up mode. The SV screen displays the current setting value and flashes. Use the [▲] or [▼] buttons to change the value. Hold the [▲] or [▼] buttons to change the value rapidly. Press the [SET] button again to save settings and exit. Settings are also saved and the mode is exited if there is no operation for 10 seconds.
5.1.3 Normal Setting
Hold the [SET] button for 2 seconds to enter setting mode. The PV screen displays the menu code "HS" for the first item, and the SV screen displays the corresponding setting value. Press the [SET] button to switch between menu items. Use the [▲] or [▼] buttons to change the value. The value is saved automatically when switching to another menu item by pressing [SET].
Press and hold the [SET] button for 2 seconds to save settings and exit. The controller also exits setting mode and returns to normal working mode if there is no operation for 30 seconds.
5.2 Flowchart of the Settings
[Diagram showing the settings flowchart: Press SET for over 2 seconds to enter parameters setting mode. HS (Humidity Setting Value), HD (Humidification Difference Value), DD (Dehumidification Difference Value), AH (Alarm High Humidity Limit), AL (Alarm Low Humidity Limit), PT (Dehumidification Delay Time), CA (Humidity Calibration). Options to press SET or wait for 30 seconds to return to Working normally.]
5.3 Icons in this Manual
Symbol | Icon | Function | Setting Range | Factory Settings | Note |
---|---|---|---|---|---|
HS | [HS Icon] | Humidity Setting Value | 5.0%RH~99.0%RH | 50.0%RH | See 6.1 |
HD | [HD Icon] | Humidification Difference Value | 1.0%RH~20.0%RH | 5.0%RH | See 6.1 |
DD | [DD Icon] | Dehumidification Difference Value | 1.0%RH~20.0%RH | 5.0%RH | |
AH | [AH Icon] | Alarm High Humidity Limit | 5.0%RH ~99.0%RH | 99.0%RH | See 6.2 |
AL | [AL Icon] | Alarm Low Humidity Limit | 5.0%RH ~99.0%RH | 5.0%RH | |
PT | [PT Icon] | Dehumidification Delay Time | 0~10 Minutes | 0 Minute | See 6.3 |
CA | [CA Icon] | Humidity Calibration | -20.0%RH ~20.0%RH | 0.0%RH | See 6.4 |
06 Basic Operations
6.1 Instructions for Humidity Control Setting (HS,HD,DD)
The PV Screen displays the current humidity. The device automatically recognizes and switches between humidification and dehumidification modes.
- Humidification: If measured Humidity(PV) ≤ Humidity Setting Value(HS) - Humidification Differential Value(HD), the equipment enters humidification state. The red LED turns on, and WORK1 output socket turns on. If measured Humidity(PV) ≥ Humidity Setting Value(HS), the red LED turns off, and WORK1 output socket turns off.
- Dehumidification: If measured Humidity(PV) ≥ Humidity Setting Value(HS) + Dehumidification Differential Value(DD), the equipment enters dehumidification state. The green LED turns on, and WORK2 output socket turns on. If the green LED blinks, it indicates the dehumidification delay protection state, and WORK2 output socket turns off. If measured Humidity(PV) ≤ Humidity Setting Value(HS), the green LED turns off, and WORK2 output socket turns off.
Example: HS=50.0%RH, HD=5.0%RH, DD=8.0%RH. If PV ≥ 58.0%RH (HS+DD), dehumidification starts (green LED ON, WORK2 ON). If PV ≤ 55.0%RH (HS), green LED OFF, WORK2 OFF. If PV ≤ 45.0%RH (HS-HD), humidification starts (red LED ON, WORK1 ON). If PV ≥ 50.0%RH (HS), red LED OFF, WORK1 OFF.
Note: When powering on or exiting the setting state, the differential values do not need to be judged. For example, if HS=50.0%RH, HD=5.0%RH, DD=8.0%RH: If PV > 50.0%RH (HS), dehumidification state is entered. When PV ≤ 50.0%RH (HS), dehumidification stops, returning to normal humidity control mode. If PV < 50.0%RH, humidification state is entered.
6.2 High/Low Humidity Alarm (AH,AL)
The equipment alarms if measured humidity (PV) ≥ high humidity alarm set value (AH). The PV screen displays the AH value and current humidity alternately, with a "bi-bi-Biii" buzzer sound until PV < AH. Pressing any button stops the alarm.
The equipment alarms if measured humidity (PV) ≤ low humidity alarm set value (AL). The PV screen displays the AL value and current humidity alternately, with a "bi-bi-Biii" buzzer sound until PV > AL. Pressing any button stops the alarm.
Note: The setting value of AL should be less than the setting value of AH.
6.3 Dehumidification Delay Time (PT)
The equipment will not start dehumidification immediately for the first time if the measured value is larger than the sum of the set humidity value and the dehumidification return difference. It will start dehumidifying after the set delay time.
The equipment dehumidifies immediately if the interval time between two adjacent dehumidifications is longer than the delay time.
The equipment dehumidifies after the delay time if the interval time between two adjacent dehumidifications is shorter than the delay time.
The delay time starts timing when the last dehumidification is completed.
Note: When powering on or exiting the setting state, the delay time does not need to be judged.
6.4 Humidity Calibration (CA)
If the measured humidity differs from the standard humidity, calibrate the device by adding or reducing a correction value to align the measured humidity with the standard humidity. Calibrated humidity = measured humidity value + calibration value.
07 Sensor Fault Alarm
If the humidity sensor has a short circuit or open circuit, the controller enters probe fault mode and stops running. The buzzer will alarm, and the screen will display "ER". Pressing any key stops the buzzer. The controller returns to normal working state when all malfunctions are resolved.
08 Important Safeguards
Take special care when using electrical appliances. Follow these safety tips:
- Read all instructions.
- Check that flexible leads and the appliance are in good condition.
- Check your plug sockets are not overloaded with too many electrical appliances to prevent overheating.
- Do not use the appliance for anything other than its intended use.
- Do not cut the cord or place it on hot surfaces.
- Do not place on or near a hot gas or electric burner, or in a heated oven.
- Do not attempt to clean or repair the appliance while it is still plugged in.
- Do not wrap flexible cables around the appliance when it is still warm.
- Switch off the device when not in use.
- Disconnect the power immediately if the device falls into water. The warranty does not cover water damage.
- This appliance is not intended for use by persons (including children) with reduced physical, sensory, or mental capabilities, or lack of experience and knowledge, unless they have been given supervision or instruction concerning use of the appliance by a person responsible for their safety. Children should be supervised to ensure they do not play with the appliance. Close supervision is necessary when any appliance is used by or near children.
09 Warranty
This Limited Warranty applies only to the INKBIRD IHC-200-WIFI Humidity Controller.
What is Covered and for How Long
INKBIRD warrants that all new products are free from defects in manufacturing, materials, and workmanship for a period of one year from the date of retail purchase.
What this Warranty Does Not Cover
The warranty does not cover defects or malfunctions caused by misuse, abuse, improper maintenance, failure to follow operating instructions, or use with equipment for which it is not intended. The warranty also does not apply to damage caused by unauthorized alteration, modification, or repair of the product. INKBIRD does not warrant or provide service or support for any third-party products, including iPhones and Android Phones.
How to Obtain Warranty Service
To obtain warranty service for products purchased from a third-party, retail, or directly from INKBIRD, return the product with proof of purchase using the following procedures:
- Contact INKBIRD Customer Support for specific return and shipping instructions via email at support@inkbird.com. You may be asked to complete a warranty service request form. To ensure warranty claims are for INKBIRD products, the technical support department may require a copy of your purchase receipt.
- Label and ship the product, freight prepaid, to the address provided by INKBIRD.
Exclusions and Limitations
THIS WARRANTY IS YOUR EXCLUSIVE WARRANTY AND REPLACES ALL OTHER WARRANTIES OR CONDITIONS, EXPRESS OR IMPLIED, INCLUDING, BUT NOT LIMITED TO, ANY IMPLIED WARRANTIES OR CONDITIONS OF MERCHANTABILITY OR FITNESS FOR A PARTICULAR PURPOSE. AS SOME STATES OR JURISDICTIONS DO NOT ALLOW THE EXCLUSION OF EXPRESS OR IMPLIED WARRANTIES, THE ABOVE EXCLUSION MAY NOT APPLY TO YOU. IN THAT EVENT, SUCH WARRANTIES APPLY ONLY TO THE EXTENT AND FOR SUCH DURATION AS REQUIRED BY LAW AND ARE LIMITED IN DURATION TO THE WARRANTY PERIOD. AS SOME STATES OR JURISDICTIONS DO NOT ALLOW LIMITATIONS ON THE DURATION OF AN IMPLIED WARRANTY, THE ABOVE LIMITATION ON DURATION MAY NOT APPLY TO YOU.
10 FCC Requirement
Changes or modifications not expressly approved by the party responsible for compliance could void the user's authority to operate the equipment.
This device complies with Part 15 of the FCC Rules. Operation is subject to the following two conditions:
- This device may not cause harmful interference.
- This device must accept any interference received, including interference that may cause undesired operation.
Note: This equipment has been tested and found to comply with the limits for a Class B digital device, pursuant to Part 15 of the FCC Rules. These limits are designed to provide reasonable protection against harmful interference in a residential installation. This equipment generates, uses, and can radiate radio frequency energy, and if not installed and used in accordance with the instructions, may cause harmful interference to radio communications. However, there is no guarantee that interference will not occur in a particular installation. If this equipment does cause harmful interference to radio or television reception, which can be determined by turning the equipment off and on, the user is encouraged to try to correct the interference by one or more of the following measures:
- Reorient or relocate the receiving antenna.
- Increase the separation between the equipment and receiver.
- Connect the equipment into an outlet on a circuit different from that to which the receiver is connected.
- Consult the dealer or an experienced radio/TV technician for help.
This equipment complies with FCC radiation exposure limits set forth for an uncontrolled environment. This equipment should be installed and operated with a minimum distance of 20cm between the radiator & your body. This transmitter must not be co-located or operating in conjunction with any other antenna or transmitter.
11 IC Warning
This device contains licence-exempt transmitter(s)/receiver(s) that comply with Innovation, Science and Economic Development Canada's licence-exempt RSS(s). Operation is subject to the following two conditions:
- This device may not cause interference.
- This device must accept any interference, including interference that may cause undesired operation of the device.
The device meets the exemption from the routine evaluation limits in section 2.5 of RSS 102 and compliance with RSS-102 RF exposure. Users can obtain Canadian information on RF exposure and compliance.
This transmitter must not be co-located or operating in conjunction with any other antenna or transmitter.
This equipment should be installed and operated with a minimum distance of 20 centimeters between the radiator and your body.
French Translation:
L'émetteur/récepteur exempt de licence contenu dans le présent appareil est conforme aux CNR d'Innovation, Sciences et Développement économique Canada applicables aux appareils radio exempts de licence. L'exploitation est autorisée aux deux conditions suivantes :
- L'appareil ne doit pas produire de brouillage;
- L'appareil doit accepter tout brouillage radioélectrique subi, même si le brouillage est susceptible d'en compromettre le fonctionnement.
Le dispositif rencontre l'exemption des limites courantes d'évaluation dans la section 2.5 de RSS 102 etla conformité à l'exposition de RSS-102 rf, utilisateurs peut obtenir l'information canadienne sur l'exposition et la conformité de rf.
Cet émetteur ne doit pas être Co-placé ou ne fonctionnant en même temps qu'aucune autre antenne ouémetteur.
Cet équipement devrait être installé et actionné avec une distance minimum de 20 centimètres entre le radiateur et votre corps.
12 Troubleshooting Guide
Issues | Causes | Solutions |
---|---|---|
Can not connect to WIFI. | 1. Incorrect phone settings. | 1. In the phone settings, ensure all permissions for the INKBIRD app are turned on. Ensure Bluetooth and location functions are turned on. |
2. Incorrect router settings. | 2. Ensure the router can transmit 2.4GHz Wi-Fi signal alone. The mobile phone must remain connected to the 2.4GHz Wi-Fi. Ensure the SSID is not hidden and the password is not empty. There is no limit on the number of connected devices. If unsure about the limit, turn off 2-3 Wi-Fi devices. Router settings: Wireless protocol: 802.11 b/g/n (not 11n only); Security mode: WPA/WPA2; Authentication type: AES; Enable DHCP service; No VPN service. | |
3. Incorrect connection mode selection. | 3. Select the correct Wi-Fi mode in the app. If many Wi-Fi products are interfering nearby, switch the device to slow flash (AP) mode to connect. | |
4. Device malfunction. | If it still does not work, please contact customer service. | |
The probe reading is incorrect. | 1. Water or condensation enters the probe. | 1. Adjust the position of the probe. |
2. The probe is placed in an area with poor humidity circulation. | 2. Use a dry cloth to clean. | |
3. The probe is damaged. | 3. If the probe is used in a high humidity environment, dry it using a hairdryer and then test it at room. | |
4. Check if the probe is intact. | ||
5. If the deviation is small, use the CA function to calibrate. | ||
work1 output will not turn on. | 1. Incorrect settings. | 1. Verify the settings are correct. |
2. Incompatible humidifier. | 2. The humidifier power should be within the range of 100-240V, 10A. The humidifier should automatically turn on when plugged in and reach the target humidity. | |
3. Output malfunction. | 3. If there are no issues with 1&2: Unplug the controller. Press and hold the [SET] button. Plug the controller back in, then release the [SET] button. Quickly press the [▲] button (do not press the [▼] button). The "work1" indicator and output should activate. If the humidifier still does not work, please contact customer service. | |
work2 output will not turn on. | 1. Incorrect settings. | 1. Verify the settings are correct. |
2. Incompatible dehumidifier. | 2. The dehumidifier power should be within the range of 100-240V, 10A. The dehumidifier should automatically turn on after power is connected and reach the target humidity. | |
3. Output malfunction. | 3. If there are no issues with 1&2: Unplug the controller. Press and hold the [SET] button. Plug the controller back in, then release the [SET] button. Quickly press the [▲] button (do not press the [▼] button). The "work2" indicator and output should activate. If the dehumidifier still does not work, please contact customer service. | |
work1 output will not turn off. | 1. Incorrect settings. | 1. Verify the settings are correct. |
2. Humidifier power exceeds limit. | 2. The humidifier power is within the range of 100-240V, 10A. | |
3. Output malfunction. | 3. If there are no issues with 1&2: Unplug the controller. Press and hold the [SET] button. Plug the controller back in, then release the [SET] button. Quickly press the [▲] button (do not press the [▼] button). The "work2" indicator and output should activate. If the humidifier still does not turn off, please contact customer service. | |
work2 output will not turn off. | 1. Incorrect settings. | 1. Verify the settings are correct. |
2. Dehumidifier power exceeds limit. | 2. The dehumidifier power is within the range of 100-240V, 10A. | |
3. Output malfunction. | 3. If there are no issues with 1&2: Unplug the controller. Press and hold the [SET] button. Plug the controller back in, then release the [SET] button. Quickly press the [▲] button (do not press the [▼] button). The "work1" indicator and output should activate. If the dehumidifier still does not turn off, please contact customer service. |