Drive Delta 1000 Ultra Light Plus, Full Electric Bed

Owner's Assembly And Operating Manual

Item # 15033

Assembly Instructions

  1. Confirm that all parts are present: Foot Spring (A), Head Spring (B), Head Board (C), Foot Board (D), Hi/Low Shaft (E), Locking Pins (F), Motor (G), Hand Crank (H - attached to foot board for shipping), Casters (I - 4 total, 2 locking, 2 non-locking), Spring Clips (J - 2), Hand Pendant (K), Full Electric Motor (L).
  2. Connect the head spring by aligning with the foot spring and swinging both ends away from each other.
  3. Optional: Insert lock pin through connected sleep surface and secure with spring clip.
  4. Place the foot spring standing up on the floor on its side. Slide Hi/Low shaft through hanger bracket.
  5. Install Hi/Low shaft to the Hi/Low motor at the foot section of the bed by inserting the spring loaded side of the shaft to the bottom receptacle as shown.
  6. Slide lock collar 1/4" from the foot side of the hanger bracket as shown. Tighten thumb screw.
  7. Hi/Low shaft connected to Hi/Low motor.
  8. Connect head section and foot section by squeezing together and attaching with spring links. Pull up the head section and foot section to release tension between the springs.
  9. Install the casters by inserting the stem of the caster into the leg receptacle. It is recommended to install 1 locking caster and 1 non-locking caster on each bed end. The locking casters should be installed diagonally from each other.
  10. With bed on side, extend the shaft until it reaches the full length of bed.
  11. NOTE: The shaft adjustment holes are marked to indicate the style (semi/full) of bed the shaft is being installed on.
  12. Attach the head board and foot board as shown.
  13. NOTE: The head section is higher than the foot section. However, they are interchangeable with each other, with all other Drive and other manufacturers head and foot boards.
  14. Install the head end of the shaft as shown.
  15. Release the spring loaded shaft on the hi/low motor and insert the shaft into the gear box on the footboard.
  16. Make sure the slot on the spring loaded shaft engages the roll pin on the gear box.

Motor Installation

NOTE: Before installing motor, plug hand pendant and Hi/Low motor cable into motor as shown.

  1. Connect the 9V battery (sold separately) to the battery clip on the motor. It is stored in the recess under the motor cover. With this battery installed, the motor can be operated in the event of a power failure.
  2. To install motor, remove locking caps on top of the motor.
  3. Align the motor with the actuator bar and lift the head spring to the highest position. The motor will automatically be pulled towards the bed and lock onto the actuator. Repeat for foot section.
  4. After the motor is installed, slide locking covers back on motor.

Bed Rail Installation

18. Attaching Bed Rails

a. Half rails: The head section features labels on the frame marked, "Attach Half Rails Here" and black springs for proper placement.

b. Full Rails: The foot and head section have color coded springs, labels and notches in the frame. Install the cross brace between the black springs for proper rail placement.

Optional Fixed Height Adjustment

19. Optional fixed height adjustment with lock pins.

a. The four large pins are used if the height of the bed is to be locked at a set height. Set the height of the bed so that the hole in the leg is aligned with the hole in the bed end outer leg. Insert the pin through each of the four legs and install the spring clip on each.

20. Before a mattress is laid on the bed, flip up the mattress guard to reduce the movement of the mattress.

Storage

21. Shown on Bed Storage Transporter with motor attached with storage strap Drive model # 15060.

Maintenance & Safety Checks

Drive recommends the following maintenance and cleaning procedures be conducted between users.

ELECTRONICS

BED FRAME & SLEEPING SURFACE

CLEANING

LUBRICATION & MECHANICAL

WARRANTY

During the warranty period, defective items will be repaired or replaced at Drive's option at no charge.

Specifications

DECK HEIGHT

BED HEIGHT (HIGH POSITION): 21.5"

BED HEIGHT (LOW POSITION): 15.5"

LENGTH

87.5"

DECK WIDTH

36"

ELECTRICAL

WEIGHT

CONSTRUCTION

FINISH

80" MATTRESS REQUIRED

WARNINGS

GENERAL WARNINGS

FDA Safety Guidelines

The March 2006 version of the FDA's bed safety guidelines are published by Hospital Bed Safety Workgroup. The latest revision of this document is available at http://www.fda.gov.

If the unit is not working properly, call a qualified technician to examine the unit and repair it.

Drive Medical products are specifically designed and manufactured for use in conjunction with Drive Medical accessories. Accessories designed by other manufacturers have not been tested by Drive Medical and are not recommended for use with Drive Medical products.

Keep all moving parts, including the main frame, mattress deck (head and foot springs/sections) and all drive shafts free of obstruction (i.e. blankets/sheets, heating blankets/pads, tubing, wiring, etc. and other types of products using electric cords which may get tangled around the bed, side rails or legs) during operation of the bed.

Keep the product a minimum of 12 inches away from any direct heat source.

Make sure head and foot springs/sections are connected securely to the universal bed ends before use.

Physically challenged individuals who cannot prevent themselves from rolling/climbing out of the this bed may require alternative safe means of restraint.

Procedures other than those described in this manual must be performed by a qualified technician.

Risk of injury to persons - DO NOT place video equipment such as televisions or computer monitors on bed.

NEVER allow patients to use trapeze or traction units as a total individual weight support.

Trapeze units are to be used only for assisting the patient in repositioning or transferring into or out of bed.

Trapeze units must be positioned on a universal bed end as near as possible to the center point of the bed end.

The bed is not designed to be used as a patient transport. When transporting a patient, use an approved patient transport. Otherwise, injury or damage may result.

The bed may be equipped with locking casters. When transferring into or out of the bed, always lock the locking caster(s). Inspect for correct locking action on caster locks before using bed. Even with casters properly locked, some flooring surfaces such as tile or wood, will allow the bed to move under some conditions. Use on surfaces such as these must be evaluated by the care provider.

The initial set up of this bed must be performed by a qualified technician.

Weight Limits and Entrapment Risks

The total weight limit of the Drive Medical 36-inch (91.4 cm) wide Manual/Electric bed (including accessories, mattress, occupant and any other person/object positioned on the bed) is 450 pounds (204 kg.); 350 pounds (158 kg) patient weight.

Use this bed only for its intended use as described in these instructions. DO NOT use attachments not recommended by the manufacturer.

After raising/lowering the head/foot end of the bed, check the distance between the bottom of the bed rail and the mattress. If there is excessive distance between the bottom of the bed rail and the mattress in which individuals may become entangled, adjust the height of the bed rail (if applicable), or provide alternative means of patient protection.

Once patient assessment concludes that the patient's condition increases the chance of entrapment, the bed MUST be in the flat position when left unattended.

Proper patient assessment and monitoring, and proper maintenance and use of equipment is required to reduce the risk of entrapment. Variations in bed rail dimensions, and mattress thickness, size or density could increase the risk of entrapment. Visit the FDA website at http://www.fda.gov to learn about the risks of entrapment.

Replacement mattresses and bed side rails with dimensions different than the original equipment supplied or specified by the bed frame manufacturer are not interchangeable. Variations in bed side rail design, width and thickness or firmness of the mattress could cause/contribute to entrapment. Use only authorized Drive Medical replacement parts and/or accessories otherwise the warranty is void. Drive Medical will not be responsible for any damage or injury that may result.

To reduce the risk of entrapment make certain that the bed rail cross braces DO NOT exceed the width of the mattress. Mattress MUST fit bed frame and side rails snugly to reduce the risk of entrapment.

When operating this bed, ALWAYS ensure that the individual utilizing the bed is positioned properly within the confines of the bed. DO NOT let any extremities protrude over the side or between the bed rails when performing these functions.

Drive Medical recommends that the mattress be centered on the bed frame. Otherwise, individuals may become entangled between the bed rail and the bed frame.

Mattress MUST fit bed frame and assist rails snugly to reduce the risk of entrapment.

SAVE THESE INSTRUCTIONS

NOTE: Updated versions of this manual are available on www.DriveMedical.com.

BED RAIL WARNINGS

ELECTRICAL WARNINGS

General Electrical and Usage Warnings

PDF preview unavailable. Download the PDF instead.

15033 Full electric Bed - Delta 1000 Manual ?v=1716848499 Adobe PDF Library 10.0.1 Adobe InDesign CS6 (Macintosh)

Related Documents

Preview Drive Medical Delta 1000 Ultra Light Plus, Full Electric Bed Owner's Assembly and Operating Manual
Assembly and operating instructions for the Drive Medical Delta 1000 Ultra Light Plus, Full Electric Bed. Includes parts list, assembly steps, motor installation, bed rail installation, optional height adjustment, storage, maintenance, safety checks, specifications, and warnings.
Preview Drive Delta 1000 Ultra Light Plus Full Electric Bed Owner's Assembly and Operating Manual
Assembly, operation, maintenance, and safety instructions for the Drive Delta 1000 Ultra Light Plus Full Electric Bed (Item # 15033). Includes detailed steps, warnings, and specifications.
Preview Drive Medical Delta 1000 Ultra Light Plus Semi Electric Bed Assembly and Operating Manual
Comprehensive assembly and operating instructions for the Drive Medical Delta 1000 Ultra Light Plus Semi Electric Bed (Item # 15030), covering parts identification, assembly steps, maintenance, safety precautions, specifications, and warnings.
Preview Delta 1000 Ultra Light Plus Semi Electric Bed: Owner's Assembly and Operating Manual
Comprehensive guide for assembling, operating, and maintaining the Drive Medical Delta 1000 Ultra Light Plus Semi Electric Bed (Item # 15030), including safety warnings and specifications.
Preview Drive Medical Hospital Beds 15005LP, 15004P, 15003P: Owner's Assembly and Operating Manual
This manual provides comprehensive assembly, operating, and safety instructions for Drive Medical's 15005LP Full Electric, 15004P Semi-Electric, and 15003P Manual Hospital Beds. It includes detailed technical specifications, maintenance procedures, troubleshooting guidance, and important safety warnings.
Preview Drive Delta Ultra-Light 1000 Semi-Electric Hospital Bed | Features & Specs
Explore the Drive Delta Ultra-Light 1000 Semi-Electric Hospital Bed. Discover its universal compatibility, safety features, specifications, and available accessories. Ideal for home healthcare.
Preview Drive Full-Electric Lightweight Bariatric Bed 15300LW Owner's Manual
This comprehensive owner's assembly and operating manual provides detailed instructions for the Drive Full-Electric Lightweight Bariatric Bed, model 15300LW. It covers safety precautions, assembly, operation, maintenance, and technical specifications for this medical bed.
Preview Drive Medical 15005L Full Electric Low Height Bed Owner's Manual and Assembly Instructions
This manual provides comprehensive owner's and assembly instructions for the Drive Medical 15005L Full Electric Low Height Bed. It covers packaging, handling, inspection, storage, assembly steps, operation, maintenance, safety checks, and important warnings.