Airplus Dehumidifier User Manual

Model: AP16-602EE

Important Safety Information

⚠️ WARNINGS

This appliance can be used by children aged from 8 years and above and persons with reduced physical, sensory or mental capabilities or lack of experience and knowledge if they have been given supervision or instruction concerning use of the appliance in a safe way and understand the hazards involved. Children shall not play with the appliance. Cleaning and user maintenance shall not be made by children without supervision.

Contents

Notice of Compressor Running Status

It's a normal phenomenon that the compressor and fan keep running when the ambient humidity reaches the preset RH. The fan stops 5 minutes after the preset RH is reached. The compressor stops when the ambient humidity is 4% lower than the preset RH, and it starts automatically when the ambient humidity level is 4% higher than the preset level. The Return Difference design featuring 4% error range is for better protecting and prolonging lifespan of the appliance.

Before First Use

To prevent any unintended damage, please leave the appliance standing upright and outside the box for 2 HOURS before plugging it in. It is very important to keep the appliance upright on a flat surface during use.

[Diagram: Dehumidifier shown standing upright on a flat surface.]

Important Safety Instructions

  1. Keep the dehumidifier upright and make sure there is at least 10-inch space around it.
  2. After being carried or tilted, the dehumidifier needs to stop for 2 hours until used again.
  3. Keep foreign objects away from the air inlet and outlet.
  4. Please turn the dehumidifier off and empty the water tank before moving it.
  5. Do not clean the dehumidifier with spray or other flammable detergents.
  6. Please turn the dehumidifier off and unplug it if it breaks down.
  7. If the power cord is broken, please contact us at us.airplus@gmail.com immediately. We will send you a free replacement or a full refund.

Product Details

The dehumidifier has the following components:

[Diagram: Front view of the dehumidifier showing numbered components: 1. Control Panel, 2. Air Inlet, 3. Filter, 4. Water Tank, 5. Caster. Back view showing numbered components: 6. Handle, 7. Handle of Water Tank, 8. Air Outlet, 9. Continuous Drainage Outlet, 10. Power Cord.]

Operation

Control Panel

[Diagram: Dehumidifier control panel featuring buttons labeled ON/OFF, HUM, TIMER, SPEED, MODE. Indicator lights are shown for HI, LO, ANION, °F, RH, TIMER, Full Tank, and Power.]

Powering On/Off: Plug in the power cord; an alarm sound indicates the appliance is ready. Press the "ON/OFF" button to turn the dehumidifier on or off.

Setting Humidity: Press "HUM" to set your desired humidity level (RH 40%-80%) or select "CO" for continuous operation.

Timer Function: Press "TIMER" to predetermine the 24-hour auto shut-off/turn-on timing switch.

Fan Speed: Press "SPEED" to switch the airflow speed between high (HI) and low (LO). The corresponding indicator light will illuminate.

Temperature Display: Press "SPEED" and "MODE" simultaneously; the display will show the ambient temperature.

Mode Selection: Press "MODE" to switch between dehumidification and air-supply modes. The appliance will not dehumidify when in air-supply mode.

Indicator Lights:

Special Functions:

Drainage

There are two methods of drainage:

01 Manual Drainage

When the water tank is full, the dehumidifier will alarm and stop working automatically. The "Full Tank Indicator Light" will turn on. It is recommended to pour out the water from the tank.

  1. Gently remove the water tank.
  2. Empty the tank and place it back correctly. If the tank is not positioned correctly, the indicator light will remain on.

[Diagram: The water tank is shown being gently removed from the dehumidifier.]

02 Continuous Drainage (optional)

This method allows for continuous drainage without the need to manually empty the tank.

[Diagram: Dehumidifier shown with a hose attached to the continuous drainage outlet. Components labeled: Rubber Cap B, Rubber Cap A, Long Hose.]

  1. Remove Rubber Cap A from the continuous drainage outlet and take off Rubber Cap B. Plug the long hose into the continuous drainage outlet. Ensure the hose is directed downwards for proper drainage.
  2. Insert the removed Rubber Cap A into "Hole A" on the dehumidifier. Then, place the water tank back into the dehumidifier.

[Diagram: A close-up view shows Rubber Cap A being inserted into "Hole A" on the dehumidifier.]

Activated Carbon Filter

An additional activated carbon filter is provided for absorbing unpleasant odors. To install, remove the existing filter, place the activated carbon filter between the original filter and the grid, and then reassemble all parts.

[Diagram: An exploded view of the filter assembly, illustrating the original filter, the activated carbon filter, and the protective grid.]

Care & Cleaning

Attention: Always keep the machine unplugged before performing any maintenance or washing procedures.

  1. Please clean the dehumidifier after turning it off for at least 1 hour.
  2. Use a slightly water-dampened cloth to clean the exterior of the dehumidifier.
  3. Do not use volatile chemicals, gasoline, detergent, chemically treated fabrics, or other cleaning solutions, as they may cause damage to the dehumidifier.
  4. Do not wash the dehumidifier directly with water.

Clean The Filter

A dry and clean filter is crucial for maintaining effective dehumidifying performance. It is recommended to clean and dry the filter every two weeks.

[Diagram: Steps for cleaning the filter are illustrated: 1. Remove the water tank and then take out the filter. 2. Remove dirt and wash the filter. 3. Leave the filter to air-dry completely in the shade.]

Storage

If the dehumidifier will not be used for an extended period, please store it following these instructions:

  1. Turn off the dehumidifier, unplug it from the power source, and secure the power cord.
  2. Empty the water tank and ensure it is completely dry.
  3. Clean the filter and ensure it is thoroughly dry.
  4. Store the dehumidifier in a location that is not exposed to direct sunlight.

Notice of Continuous Drainage

Wrong Use Methods

  1. If a U-shape or V-shape is present in the hose, accumulated water can obstruct drainage, potentially causing backflow into the water tank or leaks from other lower parts of the appliance.
  2. If there is insufficient space between the hose outlet and the water collecting vessel, increased water pressure due to rising water levels can lead to drainage failure. This may result in backflow into the water tank or leaks from other lower parts of the appliance.

[Diagram: An illustration depicts incorrect hose placement for continuous drainage, showing a U-bend where water accumulates, hindering proper flow.]

[Diagram: An illustration shows incorrect hose placement for continuous drainage where insufficient space between the hose outlet and the collection vessel causes water backup and potential leaks.]

Advised Use Methods

Method 1: For external water collecting vessel

Please adhere to the following guidelines:

  1. Ensure the hose is directed downwards.
  2. Verify that the drainage outlet of the appliance is consistently positioned higher than the maximum water level in the collecting vessel to prevent water from flowing backward.
  3. Maintain a constant height difference of 5.5 inches between the hose outlet and the appliance's drainage outlet, ensuring the hose outlet remains lower at all times.

[Diagram: A dehumidifier is shown with a hose draining into an external container. A measurement indicates the required 5.5-inch height difference between the hose outlet and the appliance's drainage point.]

Method 2: For floor drain

Connect the hose securely to the appliance and place the opposite end directly into a floor drain for continuous drainage.

[Diagram: A dehumidifier is depicted with a hose connected, directing water into a floor drain for continuous drainage.]

Troubleshooting

Problems Probable Reasons Solutions
The dehumidifier does not work. The socket is loose.
The tank full light " " is on.
Please check the socket to ensure the machine is charged.
Please remove the water from the tank or replace the tank in its place.
Dehumidifying effect is not obvious. Or the dehumidifier is not removing moisture. The room humidity is lower than setting.
The filter is dusty.
The inlet or outlet is blocked.
Doors and windows are open.
Please reset the humidity setting of the machine to ensure it is lower than the humidity of the room.
Please clean the filter and make sure there is at least 10-inch space around the dehumidifier.
Check that all doors and windows are securely closed.
The dehumidifier is a little noisy. The vibration may be caused by uneven placement.
The filter is clogged.
The air turbine does not work.
Please put the machine in a flat place.
Please clean the filter.
Please reassemble the air turbine or remove the foreign objects.
The display shows "E1", "E2" or "H1" E1/E2: The component inside dehumidifier is under open circuit or short circuit.
H1: The indoor temperature is higher than 167°F.
Contact customer support for assistance.
Models: FDKE3802 2 Speed Dehumidifier, FDKE3802, 2 Speed Dehumidifier, Dehumidifier

PDF preview unavailable. Download the PDF instead.

88d2beed-fc7c-4362-86f1-7b9fe5625151 Corel PDF Engine Version 20.1.0.708

Related Documents

Preview Airplus Dehumidifier User Manual
User manual for the Airplus Dehumidifier, providing instructions on operation, safety, maintenance, and troubleshooting.
Preview AIRPLUS AP60-2301 Dehumidifier User Manual and Troubleshooting Guide
Explore the AIRPLUS AP60-2301 dehumidifier. This guide covers defrost methods, timer settings, troubleshooting common issues, error codes, safety precautions, and technical specifications for optimal performance.
Preview AIRPLUS AP16-602EE Dehumidifier User Manual: Operation, Safety, and Maintenance
Comprehensive user manual for the AIRPLUS AP16-602EE dehumidifier. This guide details setup, operation, safety precautions, cleaning, and troubleshooting tips for optimal performance and air quality in your home.
Preview AIRPLUS Dehumidifier User Manual - Operation, Safety, and Troubleshooting
Comprehensive user manual for the AIRPLUS Dehumidifier, covering setup, operation, safety instructions, maintenance, and troubleshooting. Learn how to use your dehumidifier effectively.
Preview Intertek Authorization to Mark: Airplus Dehumidifiers
Authorization to Mark from Intertek for Ningbo Aquart Environmental Appliance Co Ltd, covering Airplus dehumidifier models, certifying compliance with relevant safety standards.
Preview Airplus AP1907P Dehumidifier User Manual
User manual for the Airplus AP1907P 30-pint dehumidifier, covering up to 2000 sq. ft. Includes setup, operation, maintenance, and safety guidelines for home and basement use.
Preview Airplus Dehumidifier User Manual: Model AP25-2003EE Operation & Maintenance
Comprehensive user manual for the Airplus AP25-2003EE dehumidifier, covering product details, operation, cleaning, troubleshooting, and technical specifications.
Preview Airplus AP25-2003EE Dehumidifier User Manual