AIRPLUS Dehumidifier User Manual

AIRPLUS Dehumidifier User Manual

⚠️ Warnings

This appliance can be used by children aged from 8 years and above and persons with reduced physical, sensory or mental capabilities or lack of experience and knowledge if they have been given supervision or instruction concerning use of the appliance in a safe way and understand the hazards involved. Children shall not play with the appliance. Cleaning and user maintenance shall not be made by children without supervision.

Before First Use

To prevent any unintended damage, please leave the appliance standing upright and outside the box for 2 HOURS before plugging it in. It is very important to keep the appliance upright on a flat surface during use.

Diagram Description: An illustration shows the dehumidifier standing upright on a surface labeled "A FLAT SURFACE".

Important Safety Instructions

  1. Keep the dehumidifier upright and make sure there is at least 10-inch space around it.
  2. After being carried or tilted, the dehumidifier needs to stop for 2 hours until used again.
  3. Keep foreign objects away from the air inlet and outlet.
  4. Please turn the dehumidifier off and empty the water tank before moving it.
  5. Do not clean the dehumidifier with bad sprays or other flammable detergents.
  6. Please turn the dehumidifier off and unplug it if it breaks down.
  7. If the power cord is broken, please contact AIRPLUS support at us.airplus@gmail.com immediately. AIRPLUS will send you a free replacement or a full refund.

Product Details

Diagram Description: An illustration of the dehumidifier shows numbered parts:

  • 1 Control Panel
  • 2 Air Inlet
  • 3 Filter
  • 4 Water Tank
  • 5 Caster
  • 6 Handle
  • 7 Handle of Water Tank
  • 8 Air Outlet
  • 9 Continuous Drainage Outlet
  • 10 Power Cord

Operation

Control Panel

Plug in the power cord, and the alarm sound indicates the appliance is ready. Press ON/OFF [power-symbol] to turn on/off the dehumidifier.

Press HUM to set your desired humidity (RH 40%-80%) or CO (continuous operation).

Press TIMER to predetermine the 24 hrs auto shut-off/turn-on timing switch.

Press SPEED to switch the speed of airflow between high and low. Corresponding HI or LO indicator light will be on synchronously.

Press SPEED and MODE synchronously, the display will show ambient temperature.

Press MODE to switch from dehumidification/air-supply mode. Note: The appliance will not dehumidify at air-supply mode.

Indicator Lights: Air Supply Indicator Light, Full Tank Indicator Light, Power Indicator Light, Timer Indicator Light.

Functions:

  • Frost Removal Function: Auto detection of frost and auto defrosting. Keeps the appliance performing well in dehumidifying. The power indicator light will flash when functioning.
  • Anion Function: Please keep pressing the MODE button to turn on/off the function. The ANION indicator light will be on when functioning.
  • Drying Function: Choose HI airflow speed and CO status under dehumidification mode to enter drying function.

Drainage

There are two methods of drainage to choose from.

01 Manual Drainage

When the tank gets full, the dehumidifier will alarm and stop working automatically. Meanwhile, the [tank-full-symbol] indicator light will turn on. It is suggested to pour out the water in the tank.

Diagram Description: Steps for manual drainage:

  • 1. Take out the tank gently.
  • 2. Empty the tank and put it back in place (If the tank is not in the correct position, the indicator light will remain on).

02 Continuous Drainage (optional)

Diagram Description: Components for continuous drainage include Rubber Cap B, Rubber Cap A, and a Long Hose.

1. Remove rubber cap A on the continuous drainage outlet and take off rubber cap B. Plug the long hose into the continuous drainage outlet. Keep the hose downward to ensure proper drainage.

Diagram Description: Shows "Hole A" for inserting the rubber cap.

2. Take out the tank gently. 3. Insert the rubber cap from step 1 into drainage "Hole A". Then put the water tank back in the dehumidifier.

Activated Carbon Filter

There is an additional activated carbon filter for absorbing unpleasant odors while dehumidifying. Simply take out the filter and place the activated carbon filter between the original one and the grid, put them back in place after well set.

Diagram Description: Illustrates the placement of the activated carbon filter alongside the original filter.

Care & Cleaning

Attention: Keep the machine unplugged before maintaining or washing.

  1. Please clean the dehumidifier after turning it off for 1 hour.
  2. Please use slightly water-dampened cloth to clean the dehumidifier.
  3. Please do not use volatile chemicals, gasoline, detergent, chemical processed fabrics or other cleaning solutions, which may be harmful to the dehumidifier.
  4. Please do not wash the dehumidifier with water directly.

Clean the Filter

Experiment shows that a dry and clean filter is great for dehumidifying effect. Therefore, it is suggested to clean and dry up the filter every two weeks.

Diagram Description: Shows three steps for cleaning the filter:

  • 1. Remove the water tank and then take out the filter.
  • 2. Remove dirt and wash out the filter.
  • 3. Leave the filter air-dry fully in shade.

Storage

If you do not need to use the dehumidifier for a long time, please store it in the following ways:

  1. Turn off the dehumidifier, cut off the power and sort out the power cord.
  2. Empty the water tank and keep it dry.
  3. Clean the filter and dry it out.
  4. Put away the dehumidifier and place it in the position unexposed to sun.

Notice of Continuous Drainage - Wrong Use Methods

1. If there is a U shape or a V shape between two ends of the hose, the increasing accumulation of water in the valley may stop water from draining to the water collecting vessel. It eventually leads to a backflow to water tank or a water leak from other lower parts of the appliance.

Diagram Description: Shows a hose with a U-shape, leading to an accumulation of water, with an symbol indicating it's wrong.

2. If there is no space between the outlet of hose and the water collecting vessel, the increasing pressure of water caused by raising water level may result in a failure of drainage from the appliance. It eventually leads to a backflow to water tank or a water leak from other lower parts of the appliance.

Diagram Description: Shows a hose outlet too close to the water level in a vessel, with an symbol indicating it's wrong. Text below says "No space between the outlet of hose and the vessel".

Advised Use Methods

Method 1: Applicable for external water collecting vessel

Please note the following:

  1. Keep the hose downward.
  2. Make sure the drainage outlet of the appliance is always higher than the maximum water level of the water collecting vessel or water may flow backward.
  3. Make sure there is always a height difference of 5.5 in between the outlet of hose and the drainage outlet of the appliance. The outlet of hose should be 5.5 in lower all the time.

Diagram Description: Shows the dehumidifier with a hose going downwards, with a label "5.5 in" indicating the required height difference. A ✔️ symbol is shown.

Method 2: Applicable for floor drain

Well connect the hose to the appliance and place the other end to the floor drain.

Diagram Description: Shows the dehumidifier with a hose connected and directed towards a floor drain. A ✔️ symbol is shown.

Troubleshooting

PROBLEMSPROBABLE REASONSSOLUTIONS
The dehumidifier does not work.The socket is loose.Please check the socket to ensure the machine is charged.
The dehumidifier does not work.The tank full light "[tank-full-symbol]" is on.Please remove the water from the tank or replace the tank in its place.
Dehumidifying effect is not obvious. Or the dehumidifier is not removing moisture.The room humidity is lower than setting.Please reset the humidity setting of the machine to ensure it is lower than the humidity of the room.
Dehumidifying effect is not obvious. Or the dehumidifier is not removing moisture.The filter is dusty.Please clean the filter and make sure there is at least 10-inch space around the dehumidifier.
Dehumidifying effect is not obvious. Or the dehumidifier is not removing moisture.The inlet or outlet is blocked.Please clean the filter.
Dehumidifying effect is not obvious. Or the dehumidifier is not removing moisture.Doors and windows are open.Check that all doors and windows are securely closed.
Dehumidifying effect is not obvious. Or the dehumidifier is not removing moisture.The room temperature or humidity is too low.This is normal.
The dehumidifier is a little noisy.The vibration may be caused by uneven placement.Please put the machine in a flat place.
The dehumidifier is a little noisy.The filter is clogged.Please clean the filter.
The dehumidifier is a little noisy.The air turbine does not work.Please reassemble the air turbine or remove the foreign objects.
The dehumidifier is a little noisy.The air turbine does not work.Please clean the filter.
The dehumidifier is a little noisy.The filter is clogged.Please clean the filter.
The display shows "E1", "E2" or "H1"E1/E2: The component inside dehumidifier is under open circuit or short circuit.
The display shows "E1", "E2" or "H1"H1: The indoor temperature is higher than 167°F.

PDF preview unavailable. Download the PDF instead.

AIRPLUS-AP16-airplus-manual Adobe Illustrator 24.1 (Windows) iLovePDF

Related Documents

PreviewAirplus Dehumidifier User Manual - Operation, Safety, and Troubleshooting Guide
Comprehensive user manual for the Airplus Dehumidifier (Model AP16-602EE). Provides detailed instructions on setup, operation, safety precautions, cleaning, maintenance, continuous drainage, and troubleshooting common issues.
PreviewAirplus Dehumidifier User Manual
User manual for the Airplus Dehumidifier, providing instructions on operation, safety, maintenance, and troubleshooting.
PreviewAIRPLUS AP16-602EE Dehumidifier User Manual: Operation, Safety, and Maintenance
Comprehensive user manual for the AIRPLUS AP16-602EE dehumidifier. This guide details setup, operation, safety precautions, cleaning, and troubleshooting tips for optimal performance and air quality in your home.
PreviewAIRPLUS AP60-2301 Dehumidifier User Manual and Troubleshooting Guide
Explore the AIRPLUS AP60-2301 dehumidifier. This guide covers defrost methods, timer settings, troubleshooting common issues, error codes, safety precautions, and technical specifications for optimal performance.
PreviewIntertek Authorization to Mark: Airplus Dehumidifiers
Authorization to Mark from Intertek for Ningbo Aquart Environmental Appliance Co Ltd, covering Airplus dehumidifier models, certifying compliance with relevant safety standards.
PreviewAirplus Dehumidifier User Manual: Operation, Care, and Troubleshooting
Comprehensive user manual for the Airplus Dehumidifier, covering product details, operation, cleaning, maintenance, troubleshooting, and technical specifications.