Airplus Dehumidifier User Manual

⚠️ Warnings

This appliance can be used by children aged from 8 years and above and persons with reduced physical, sensory or mental capabilities or lack of experience and knowledge if they have been given supervision or instruction concerning use of the appliance in a safe way and understand the hazards involved. Children shall not play with the appliance. Cleaning and user maintenance shall not be made by children without supervision.

Product Details

The dehumidifier features the following components:

  • Air Outlet: Where the dehumidified air is expelled.
  • Control Panel: Interface for operating the unit.
  • Power Cord: Connects the unit to the power supply.
  • Handle: For carrying the unit.
  • Air filter: Captures dust and particles from the air.
  • Continuous drain: Port for continuous water drainage.
  • Air intake: Where ambient air enters the unit.
  • Water tank: Collects condensed water.
  • Remove the tank from key locations: Indicates how to access the water tank.
  • Casters: Wheels for easy mobility.

Control Panel Description:

The control panel includes:

  1. Dry button: Activates the dry mode for faster drying.
  2. Negative ion button: Activates the negative ion function.
  3. Timer keys: Set the operating timer.
  4. Humidity status indicator: Shows the current humidity level.
  5. Humidity button: Adjusts the desired humidity level.
  6. Wind speed button: Selects fan speed (low, medium, high).
  7. Standby button: Powers the unit on or off.
  8. Water full indicator: Illuminates when the water tank is full.
  9. Defrost indicator: Indicates when the unit is in defrost mode.
  10. Digital display: Shows current settings or status.
  11. Wind speed indicator: Displays the selected fan speed.

Applicable Place

This dehumidifier is suitable for a wide range of places including basements, storage rooms, libraries, archives, living rooms, bedrooms, cloakrooms, and toilets.

Position it correctly:

To ensure optimal performance, the main engine air inlet should have adequate space. Keep a distance of at least 25cm from shelters such as walls to allow for proper air circulation.

[Diagram showing the dehumidifier placed in a room with arrows indicating a 25cm clearance on all sides from walls.]

Usage Method

General Operation:

  1. Plug in the power supply. A prompt sound indicates the machine is powered on.
  2. Press the standby button. The corresponding indicator light will turn on, displaying the system's default operating mode. Press the standby button again to shut down the machine.
  3. Press the wind speed selection key to cycle through three modes: low wind, medium stroke, and high wind.
  4. In standard mode, press the 'Humidity' button to set the desired humidity level between RH40%-80% or select continuous dehumidification (CO).
  5. Press the 'Dry' button to activate the dry clothes mode; the dry icon will light up. Press the 'Dry' button again to exit dry mode and return to standard mode.
  6. Use the timer keys to set an appointment for 0-24 hours to start the machine at a fixed time (when the unit is off), or to schedule a timed shutdown (when the unit is on).
  7. Press the negative ion button to activate the negative ion function. The negative ion indicator will light up.
  8. The unit features intelligent detection of dehumidification system temperature. It will automatically enter Defrost mode to ensure efficient dehumidification performance in low-temperature environments.
  9. The unit has compressor power failure protection.

Pour Water:

  1. When the water tank is full, the machine will automatically stop dehumidifying. The 'Water full' indicator will light up, signaling that the tank needs to be emptied.
  2. Grasp the handles on both sides of the water tank and pull it outward to remove it.
  3. Empty the collected water from the tank.
  4. Place the water tank back into the unit securely. If the water tank is not properly placed, the device will not operate, and the 'Water full' indicator will remain on.

Continuous Drainage:

  1. Locate the continuous drain port on the unit (after removing the water tank).
  2. Insert a water pipe into the continuous drain port. Ensure the pipe mouth is positioned correctly within the tank or drainage system to allow condensate to be discharged smoothly.

Clean the strainer

  1. Remove the filter frame: First, remove the air inlet grille, then remove the filter frame.
  2. Dust cleaning: Use a dust collector to clean the air filter. Ensure it is dry after cleaning.
  3. Install the filter frame: Install the cleaned filter screen onto the air inlet grille, and then install the air inlet grille back onto the machine.

Basic Parameter Information

Technical Specifications for Airplus Dehumidifier AP25-2003EE
Product ModelPower SupplyRated Power/current (DB80°F RH60%)Rated Dehumidification Capacity (DB80°F RH60%)Daily Dehumidification (DB86°F RH80%)Operating Ambient TemperatureCompressorRefrigerantsWater Tank VolumeProduct WeightForm FactorExecution StandardsRemark
AP25-2003EE115~60Hz305W/3.11A0.42KG/H25L/D41-86°FReciprocatingR134a/5.82oz4.8L31.75lb38×26.8×52cmGB4706.1-2005 GB4706.32-2012 GB/T19411-2003If the technical parameters are subject to change, the nameplate shall prevail.

Matters Needing Attention

  • Keep the machine in an upright position, ensuring at least 25cm space distance around it for proper ventilation.
  • After transportation or tilting, allow the machine to stand upright for 2 hours before connecting it to the power supply.
  • Ensure the air inlet and outlet are not blocked by other objects to maintain product performance.
  • Before moving the machine, turn it off, disconnect the power, and empty the water from the tank.
  • It is strictly forbidden to use harsh or flammable detergents for cleaning the machine.
  • If the machine malfunctions, shut it down and disconnect the power first.
  • Always use a three-core socket power supply with a ground wire.
  • If the power cord is damaged, it must be replaced by qualified professionals from the manufacturer or its authorized service department to avoid danger.
  • For long periods of non-use, turn off the power, unplug the cord, drain and dry the water tank, clean the air filter, and store the unit in a cool, dry place.
  • It is recommended to clean the air filter every 3-6 months.

Warm Tips

It is necessary to prevent the drainage pipeline from freezing in cold environments.

Common Troubleshooting

Troubleshooting Guide
SymptomAnalysis of Possible CausesProcessing Method
The machine does not work1. The machine is placed unevenly or the ground is uneven, causing vibration.
2. The 'Water full' indicator is on (water tank is full or not placed correctly).
3. The room humidity is lower than the machine's set humidity value.
1. Check the power supply and socket.
2. Empty the water tank or ensure it is placed correctly.
3. Reset the humidity setting to be lower than the room humidity.
Noisy1. The air filter is too dirty, causing poor air inlet, or foreign objects are blocking the air outlet.
2. Doors and windows are not closed.
3. The room temperature is lower than 5°C or room humidity is low.
1. Clean the air filter or remove foreign matter from the air outlet.
2. Close doors and windows.
3. This is a normal phenomenon.
The wind wheel does not rotate or the air output is small1. Resonance caused by uneven machine placement or uneven ground.
2. The air filter is blocked.
3. Compressor starting period.
1. Place the machine on a horizontal ground.
2. Clean the air filter.
3. The compressor noise will disappear automatically within a few minutes after starting.
The machine does not dehumidify or has poor dehumidification effect1. The wind wheel is stuck.
2. The air filter is blocked.
1. Reassemble the wind wheel or remove foreign objects.
2. Clean the air filter.

PDF preview unavailable. Download the PDF instead.

AIRPLUS-FDKE3803 Adobe Illustrator 24.1 (Windows) GPL Ghostscript 9.25; modified using iText 5.0.3 (c) 1T3XT BVBA

Related Documents

Preview Airplus AP25-2003EE Dehumidifier User Manual
Comprehensive user manual for the Airplus AP25-2003EE dehumidifier, covering product details, operation, care and cleaning, troubleshooting, and technical specifications. Learn how to use and maintain your Airplus dehumidifier for optimal performance.
Preview Airplus Dehumidifier User Manual: Operation, Care, and Troubleshooting
Comprehensive user manual for the Airplus Dehumidifier, covering product details, operation, cleaning, maintenance, troubleshooting, and technical specifications.
Preview Airplus Dehumidifier AP25-2003EE User Manual
Comprehensive user manual for the Airplus Dehumidifier AP25-2003EE, detailing product features, operation instructions, care and cleaning procedures, troubleshooting tips, and technical specifications.
Preview Airplus AP1907P Dehumidifier User Manual
User manual for the Airplus AP1907P 30-pint dehumidifier, covering up to 2000 sq. ft. Includes setup, operation, maintenance, and safety guidelines for home and basement use.
Preview Intertek Authorization to Mark: Airplus Dehumidifiers
Authorization to Mark from Intertek for Ningbo Aquart Environmental Appliance Co Ltd, covering Airplus dehumidifier models, certifying compliance with relevant safety standards.
Preview Airplus FDKE3802 2 Speed Dehumidifier User Manual
Comprehensive user manual for the Airplus FDKE3802 2 Speed Dehumidifier, detailing safety warnings, operation instructions, product features, maintenance, and troubleshooting guidance.
Preview Airplus Dehumidifier User Manual - Operation, Safety, and Troubleshooting Guide
Comprehensive user manual for the Airplus Dehumidifier (Model AP16-602EE). Provides detailed instructions on setup, operation, safety precautions, cleaning, maintenance, continuous drainage, and troubleshooting common issues.
Preview AIRPLUS AP138-2302 Dehumidifier User Manual and Specifications
Comprehensive user manual and specifications for the AIRPLUS AP138-2302 dehumidifier, covering product introduction, operation, troubleshooting, and safety precautions.