ComfortAire Century Air Handler Heat Pump System

SUBMITTAL DATA

Models: MXP48/60D1A (48K & 60K)

General Information

Location: Approval:
Engineer: Date:
Submitted to: Construction:
Submitted by: Unit #:
Reference: Drawing #:

Indoor Unit Specifications

AHRI CERTIFIED www.ahridirectory.org

ETL Certified

Specification Value
Dimension (W×D×H) (inch) 24-1/2 x 21 x 28
Dimension (W×D×H) (mm) 622 x 533 x 711
Package Dimension (W×D×H) (inch) 27-3/4 x 26-1/8 x 30-3/8
Package Dimension (W×D×H) (mm) 705 x 665 x 770
Net/Gross Weight (lbs) 81/92
Net/Gross Weight (kg) 36.8/41.9

Indoor Unit Dimensions Table

Dimension MXP18/24B1A (inch/mm) MXP18/24A1A (inch/mm) MXP24/36A1A (inch/mm) MXP24/36B1A (inch/mm) MXP24/36C1A (inch/mm) MXP48/60C1A (inch/mm) MXP48/60D1A (inch/mm)
A: Model Height 18 / 457 18 / 457 23-5/16 / 592 23-9/16 / 599 24 / 611 24 / 611 28 / 711
B: Model Width 17-1/2 / 445 14-1/2 / 368 14-1/2 / 368 17-1/2 / 445 21 / 534 21 / 534 24-1/2 / 622
C: Supply Air Opening Width 16-3/16 / 411 13-1/4 / 336 13-1/4 / 336 16-3/16 / 411 19-3/4 / 502 19-3/4 / 502 23-1/4 / 591
D: Return Air Opening Width 14-5/16 / 380 11-15/16 / 303 11-15/16 / 303 14-15/16 / 380 19-1/2 / 498 19-1/2 / 498 23-1/8 / 587
E: Condensate Drains Height 1-7/16 / 38 1-7/16 / 38 1-7/16 / 38 1-7/16 / 38 2-3/16 / 55 2-3/16 / 55 2-3/16 / 55
F: Liquid Line Height 11-3/8 / 290 11-3/8 / 290 17-5/16 / 455 16-3/8 / 417 17-1/2 / 445 17-1/2 / 445 21-7/16 / 545

Outdoor Unit Specifications

Specification Value
Compressor Type ROTARY
Compressor Model KTQ420D1UMU
Refrigerant R454B
Refrigerant Oil Charge (mL) 1400
Refrigerant Oil VG74
Outdoor Air Flow (Max) (CFM) 3,037 (for 48K) / 4,503 (for 60K)
Outdoor Noise Level (dBA) 65 (for 48K) / 63 (for 60K)
Dimension (W×D×H) (inch) 38.58 x 16.34 x 38.39 (for 48K) / 37.48 x 16.34 x 52.48 (for 60K)
Dimension (W×D×H) (mm) 980 x 415 x 975 (for 48K) / 952 x 415 x 1,333 (for 60K)
Package Dimension (W×D×H) (inch) 45.08 x 19.68 x 42.52 (for 48K) / 43.11 x 16.34 x 58.27 (for 60K)
Package Dimension (W×D×H) (mm) 1,145 x 500 x 1,080 (for 48K) / 1,095 x 415 x 1,480 (for 60K)
Net/Gross Weight (lbs) 187.17/218.48 (for 48K) / 212.30/244.49 (for 60K)
Net/Gross Weight (kg) 84.9/99.1 (for 48K) / 96.3/110.9 (for 60K)

Efficiency

Rating Cooling Heating
SEER2 14.3 (for 48K) / 14.8 (for 60K) HSPF2-4
EER2 9.0 (for 48K) / 8.7 (for 60K) COP

Performance of Cooling

Parameter Value
Rated Capacity (Cooling Btu/hr) 46000 (for 48K) / 54000 (for 60K)
Min/Max Capacity (Cooling Btu/hr) 13600~50,000 (for 48K) / 18,000~54,000 (for 60K)
Moisture Removal (L/h) 6.1 (for 48K) / 8.5 (for 60K)
Standard Operating Range (°F/°C) -13~122 (-25~50)
Rated Cooling Conditions Indoor: 80°F DB/67°F WB
Outdoor: 95°F DB/75°F WB

Performance of Heating

Parameter Value
1. @ 47°F Rated (Heating Btu/hr) /
2. @ 47°F Min/Max Capacity /
3. @ 17°F Rated /
4. @ 5°F Rated: Capacity / COP /
5. @ 5°F Max: Capacity /
Standard Operating Range (°F/°C) /
1. Rated Heating Conditions: Indoor: 70°F DB/60°F WB
Outdoor: 47°F DB/43°F WB
2. Rated Heating Conditions: Indoor: 70°F DB/60°F WB
Outdoor: 17°F DB/15°F WB
3. Heating Conditions, Compressor Operating at Max. Frequency Indoor: 70°F DB/60°F WB
Outdoor: 5°F DB/5°F WB

Electrical Specifications

Parameter Value
Indoor Power Supply 24V, 60Hz, 1Ph
Indoor MCA 115V/(208/230V) /
Indoor MOP /
Outdoor Power Supply 208/230V, 60Hz, 1Ph
Outdoor MCA 36 (for 48K) / 37 (for 60K)
Outdoor MOP 40
Communication Wiring AWG 20-2
Compressor RLA 27 (for 48K) / 27.5 (for 60K)
Outdoor Fan Motor RLA 2.4
Outdoor Fan Motor W /
Indoor Fan Motor RLA /
Indoor Fan Motor W /
System Power Input @ Cooling (W) 5111 (1300-5700) (for 48K) / 6375 (1,580~6,375) (for 60K)
System Power Input @ Heating (W) /(/)
MCA: Min. circuit amps (A)
RLA: Rated load amps (A)
MOCP: Max. over current protection (A)
W: Fan motor rated output (W)

Piping Specifications

Parameter Value
Throttle type (Indoor) EXV
Throttle type (Outdoor) /
Liquid Size 9.52mm(3/8in)
Gas Size 19mm(3/4in)
Max. Piping Length (ft/m) 246(75)
Max. Height Difference (ft/m) 98(30)
Max. Pre-charged Length (ft/m) 24.6(7.5)
Refrigerant Pre-charged Amount (oz/kg) 141.10(4.00) (for 48K) / 169.32(4.80) (for 60K)
Additional Charge of Refrigerant ((oz/ft)/(g/m)) 0.7(65)
Connection Method Flared

Features

Outdoor Unit Installation Instructions

Maintain adequate clearance around the outdoor unit for proper airflow and service access:

Ensure proper mounting using bolts for installation.

PDF preview unavailable. Download the PDF instead.

MXP 48-60D1A Submittal 6-20-25 ?MOD=AJPERES&CONVERT TO=url&CACHEID=ROOTWORKSPACE-e2ea3f8b-0758-4dba-b3f7-67300b1f30d3-puDPCSE Adobe InDesign 20.4 (Windows) Adobe PDF Library 17.0

Related Documents

Preview ComfortAire Century CXP1548SA-1 Air Handler Heat Pump System Submittal Data
This document provides submittal data for the ComfortAire Century CXP1548SA-1 Air Handler Heat Pump System, including detailed specifications, performance data, dimensions, and electrical information.
Preview ComfortAire Century CXP1524SA-1 Air Handler Heat Pump System Submittal Data
Submittal data for the ComfortAire Century CXP1524SA-1 Air Handler Heat Pump System, including specifications for cooling, heating, electrical, and piping.