ComfortAire Century CXP1548SA-1 Air Handler Heat Pump System
Submittal Data
Model: CXP1548SA-1
Product Type: Air Handler Heat Pump System
Certifications: AHRI CERTIFIED, ENERGY STAR, ETL
Indoor Specifications
Specification | Value |
---|---|
Dimension (W×D×H) (inch) | 21.61 x 21.50 x 27.80 |
Dimension (W×D×H) (mm) | 549×546×706 |
Package (W×D×H) (inch) | 31.69 x 25.59 x 26.57 |
Package (W×D×H) (mm) | 805×650×675 |
Net/Gross Weight (lbs) | 44/52 |
Net/Gross Weight (kg) | 43.9/52.2 |
Outdoor Specifications
Specification | Value |
---|---|
Compressor Type | ROTARY |
Compressor Model | KTQ420D1UMU |
Refrigerant | R454B |
Refrigerant Oil Charge (mL) | 1400 |
Refrigerant Oil | VG74 |
Outdoor Air Flow (Max) (CFM) | 3,037 |
Outdoor Noise Level (dBA) | 65 |
Dimension (W×D×H) (inch) | 38.58 x 16.34 x 38.39 |
Dimension (W×D×H) (mm) | 980×415×975 |
Package (W×D×H) (inch) | 45.08 x 19.68 x 42.52 |
Package (W×D×H) (mm) | 1,145×500×1,080 |
Net/Gross Weight (lbs) | 187.17/218.48 |
Net/Gross Weight (kg) | 84.9/99.1 |
Efficiency
Rating | Cooling (SEER2/EER2) | Heating (HSPF2-4/COP) |
---|---|---|
SEER2 | 15.3 | - |
EER2 | 9.8 | - |
HSPF2-4 | - | / |
COP | - | / |
Performance of Cooling
Specification | Value |
---|---|
Rated Capacity (Btu/hr) | 44,000 |
Min/Max Capacity (Btu/hr) | 17,600~52,000 |
Moisture Removal (L/h) | 6.31 |
Standard Operating Range (°F/°C) | -13~122 (-25~50) |
Rated Cooling Conditions | Indoor: 80°F DB/67°F WB, Outdoor: 95°F DB/75°F WB |
Performance of Heating
Specification | Value |
---|---|
1. @ 47°F Rated (Btu/hr) | / |
2. @ 47°F Min/Max Capacity | / |
3. @ 17°F Rated (Btu/hr) | / |
4. @ 5°F Rated: Capacity / COP | / |
5. @ 5°F Max: Capacity | / |
Standard Operating Range (°F/°C) | / |
Rated Heating Conditions: | Indoor: 70°F DB/60°F WB, Outdoor: 47°F DB/43°F WB |
2. Rated Heating Conditions: | Indoor: 70°F DB/60°F WB, Outdoor: 17°F DB/15°F WB |
3. Heating Conditions, Compressor Operating at Max. Frequency | Indoor: 70°F DB/60°F WB, Outdoor: 5°F DB/5°F WB |
Electrical
Specification | Value |
---|---|
Indoor Power Supply | 24V, 60Hz, 1Ph |
Indoor MCA (A) | / |
Indoor MOP (A) | / |
Outdoor Power Supply | 208/230, 60Hz, 1Ph |
Outdoor MCA (A) | 36 |
Outdoor MOP (A) | 40 |
Communication Wiring | AWG 20-2 |
Compressor RLA (A) | 27 |
Outdoor Fan Motor RLA (A) | 2 |
Outdoor Fan Motor W | / |
Indoor Fan Motor RLA (A) | / |
Indoor Fan Motor W | / |
System Power Input @ Cooling (W) | 4,490 (1,510 ~ 5,500) |
System Power Input @ Heating (W) | /(/) |
MCA: Min. circuit amps (A) | MOCP: Max. over current protection (A) |
RLA: Rated load amps (A) | W: Fan motor rated output (W) |
Piping
Specification | Value |
---|---|
Throttle type (Indoor) | EXV |
Throttle type (Outdoor) | / |
Liquid Size | 9.52mm (3/8in) |
Gas Size | 19mm (3/4in) |
Max. Piping Length (ft/m) | 246 (75) |
Max. Height Difference (ft/m) | 98 (30) |
Max. Pre-charged Length (ft/m) | 24.6 (7.5) |
Refrigerant Pre-charged Amount (oz/kg) | 141.10 (4.00) |
Additional Charge of Refrigerant (oz/ft) / (g/m) | 0.7 (65) |
Connection Method | Flared |
Indoor Unit Dimensions
Model | Dimension | Value (inch) | Value (mm) |
---|---|---|---|
MXP18/24B1A | Height | 18 | 457 |
MXP18/24A1A | Height | 18 | 457 |
MXP24/36A1A | Height | 23-5/16 | 592 |
MXP24/36B1A | Height | 23-9/16 | 599 |
MXP24/36C1A | Height | 24 | 611 |
MXP48/60C1A | Height | 24 | 611 |
MXP48/60D1A | Height | 28 | 711 |
MXP18/24B1A | Width | 17-1/2 | 445 |
MXP18/24A1A | Width | 14-1/2 | 368 |
MXP24/36A1A | Width | 14-1/2 | 368 |
MXP24/36B1A | Width | 17-1/2 | 445 |
MXP24/36C1A | Width | 21 | 534 |
MXP48/60C1A | Width | 21 | 534 |
MXP48/60D1A | Width | 24-1/2 | 622 |
MXP18/24B1A | Supply Air Opening Width | 16-3/16 | 411 |
MXP18/24A1A | Supply Air Opening Width | 13-1/4 | 336 |
MXP24/36A1A | Supply Air Opening Width | 13-1/4 | 336 |
MXP24/36B1A | Supply Air Opening Width | 16-3/16 | 411 |
MXP24/36C1A | Supply Air Opening Width | 19-3/4 | 502 |
MXP48/60C1A | Supply Air Opening Width | 19-3/4 | 502 |
MXP48/60D1A | Supply Air Opening Width | 23-1/4 | 591 |
MXP18/24B1A | Return Air Opening Width | 14-5/16 | 380 |
MXP18/24A1A | Return Air Opening Width | 11-15/16 | 303 |
MXP24/36A1A | Return Air Opening Width | 11-15/16 | 303 |
MXP24/36B1A | Return Air Opening Width | 14-15/16 | 380 |
MXP24/36C1A | Return Air Opening Width | 19-1/2 | 498 |
MXP48/60C1A | Return Air Opening Width | 19-1/2 | 498 |
MXP48/60D1A | Return Air Opening Width | 23-1/8 | 587 |
MXP18/24B1A | Condensate Drains Height | 1-7/16 | 38 |
MXP18/24A1A | Condensate Drains Height | 1-7/16 | 38 |
MXP24/36A1A | Condensate Drains Height | 1-7/16 | 38 |
MXP24/36B1A | Condensate Drains Height | 1-7/16 | 38 |
MXP24/36C1A | Condensate Drains Height | 2-3/16 | 55 |
MXP48/60C1A | Condensate Drains Height | 2-3/16 | 55 |
MXP48/60D1A | Condensate Drains Height | 2-3/16 | 55 |
MXP18/24B1A | Liquid Line Height | 11-3/8 | 290 |
MXP18/24A1A | Liquid Line Height | 11-3/8 | 290 |
MXP24/36A1A | Liquid Line Height | 17-5/16 | 455 |
MXP24/36B1A | Liquid Line Height | 16-3/8 | 417 |
MXP24/36C1A | Liquid Line Height | 17-1/2 | 445 |
MXP48/60C1A | Liquid Line Height | 17-1/2 | 445 |
MXP48/60D1A | Liquid Line Height | 21-7/16 | 545 |
Outdoor Unit Dimensions
Diagrams illustrating the outdoor unit dimensions and installation clearances are provided.
Installation Clearances:
- 4 inches (100mm) or more clearance on the front and sides of the unit.
- 20 inches (500mm) or more clearance on the front and sides of the unit when any 2 sides (left, right, rear) are clear.
- 14 inches (350mm) or more clearance on the rear of the unit.
Features
- Multi-position installation: horizontal (left or right), vertical (up or down).
- Aluminum Coil.
- R454B refrigerant sensor.
- Easy Maintenance.
- Multiple control options available:
- Two-way communication wired controller with built-in WiFi: 120N(X6W).
- Third-Party 24V Thermostat.