Product Overview

This battery-operated smoke detector is a smart plug-and-play product with photoelectric sensing technology that detects smoke at an early stage. If the smoke concentration level reaches the alarm threshold in the detector's smoke chamber, it sets off an alarm by flashing the LED. The inbuilt buzzer is activated, providing an audio and visual indication to all occupants. The detector raises a local alarm and quickly uses the unified IMPACT Honeywell mobile app to send incoming call alerts to your mobile, wherever you are. Keep your premises safe from fire hazards with real-time proactive alerts from the wireless smoke detector.

Product Features & Technical Specifications

FeatureSpecification
Size102mm × 44mm
Weight96g
Temperature Range0°C to 49°C
Humidity Range5% to 85% relative humidity (RH), non-condensing
Working Voltage3.0 VDC
Battery4 x AA batteries (Recommended Brands: Energizer, Duracell, Panasonic, BP)
Battery Service Life1 year under normal operating conditions (life may reduce depending on operating condition)
Audio Alarm>75dB(A) at 3mtr
Network Function2.4GHz Single Band Wi-Fi
Indication TypeLED (Red & Green) and Buzzer
Max. Standby Current12μA
Max. Alarm Current150mA
CertificationWPC, CE

Test Procedure

Sr. No.App NotificationConditionProcedureTest Button PressRed LEDGreen LEDBuzzer
1.NotificationSelf TestPress the test button once and wait for 3 seconds1 pressONOFFON
2.Device name & location is updatedWi-Fi ProvisioningPress the test button 3 times to activate the WiFi hotspot of the device3 pressRED LED blinks every 3 secondsOFFBeep for 1 sec on successful configuration
3.Notification of alert (app notification and direct call on mobile)FireON till smoke is present in the deviceBlink every 1 secondOFF
4.Heartbeat indicationNetwork FunctionEvery 20 mins to check the device statusBlink once every 20 minutesOFFNo app notification
5.Battery Low alert on APPBattery LowBlink every 15 secondsOFFOFFLOW BATTERY
6.Device Offline alert on APPDevice Offline (Device is not connected to internet)

Box Contains

  • Wireless Smoke Detector (1 No.)
  • Mounting Screws (2 Nos.)
  • Screw Plugs (2 Nos.)
  • User Manual (1 No.)
  • Template for Screw Mounting (1 No.)

Applicable Places

Suitable for residential areas, shopping malls, warehouses, restaurants, parking lots, libraries, schools and hospitals.

Instructions

Pre-Installation

  1. Insert four AA batteries into the battery compartment. Ensure correct polarity. Use new batteries and do not mix old and new ones. Do not use rechargeable batteries.
  2. Do not use an open flame to test the alarm; this could damage the alarm or start a fire.

App Setup and Configuration

Follow these steps to set up the IMPACT by Honeywell app and configure the device:

  1. Download the IMPACT by Honeywell app from the Play Store or App Store.
  2. Open the app and tap "Create Account".
  3. Fill in required details, agree to T&C and Legal, then tap "Create Account".
  4. Check your email for a confirmation from Honeywell. Click the confirmation link. If not received, tap "Resend Confirmation e-mail".
  5. Open the app and log in using your email and password.
  6. To add a device, tap the "+" button or navigate to Menu > "Device Setup".
  7. Tap on "Wireless Smoke Detector".
  8. Read the instruction popup and tap "I'm ready".
  9. Ensure the device is in active configuration mode (RED LED blinks every 3 seconds). If "WSD_Honeywell" does not appear, refresh or restart the device and mobile Wi-Fi.
  10. Select your Wi-Fi network, enter the password, select/add a location, and enter a device name.
  11. Tap "Connect" to start the configuration process.
  12. Upon successful configuration, a confirmation screen will appear, and the device will beep. The RED LED will turn green when the device is online.
  13. Tap "Go To Home" to return to the app's home screen where the added device will be visible.
  14. Tap the newly added device and then "Buy New Subscription".
  15. Select a subscription plan and click "Purchase".
  16. Fill in payment details, accept terms, and tap "Purchase".
  17. Tap "Go back to the app" upon completion.
  18. Subscription details can be viewed via Menu > Account > Device.

Installation Position

Follow these guidelines for optimal placement:

  • Indoor use only.
  • Maintain at least 0.5 meters horizontal distance from lighting equipment.
  • Maintain at least 0.5 meters horizontal distance from walls and beam edges.
  • Maintain at least 1.5 meters horizontal distance from ventilation fans, air conditioners, or vents.
  • Do not install in bathrooms or areas prone to water splashes or condensation.
  • Do not install in kitchens or areas prone to non-fire smoke or steam.

Installation of Device

Before mounting:

  1. Test the device by pressing the test button once. Confirm the RED LED flashes quickly and the buzzer sounds. An alert should be received on your mobile if the device is online.

Mounting steps:

  1. Use the provided template to mark two holes on the ceiling.
  2. Install expansion plugs into the marked holes.
  3. Insert screws into the ceiling, leaving a 3mm gap.
  4. Mount the device onto the screws and rotate clockwise to secure. Rotate anti-clockwise to remove.

Diagram Description (Fig-1): The diagram illustrates correct installation positions. It shows the smoke detector should be placed more than 0.5 meters away from walls, lighting, and air conditioning units, and more than 1.5 meters away from ventilation sources.

Maintenance

When the battery is low:

  1. Turn the device anti-clockwise to remove it from its base.
  2. Remove the used batteries.
  3. Install new batteries, ensuring correct polarity.

Notes:

  • After battery replacement, allow 5 minutes for the device to reset and recover to normal state.
  • Dispose of end-of-life products or parts according to national/local electronic waste disposal methods. Do not discard them improperly.

Edit Device

To update Wi-Fi settings:

  1. Press the test button 3 times to enable configuration mode.
  2. In the app, go to Menu > Device > Edit Device. Select the device.
  3. Select the Wi-Fi (SSID), enter the Wi-Fi password, and click "Update".
  4. Wait for confirmation. The device will be updated.

Delete Device Function

To delete a device:

  1. Factory Reset the device: Press the test button 5 times until you hear 3 beep sounds.
  2. Delete from App: Go to Menu > Device > Device Setting, tap "Delete Device", and confirm with "YES".

Smoke Alarm Limitations

  • The manual is subject to amendment by the company.
  • The alarm may not detect fires if smoke concentration doesn't reach the threshold or if smoke sources are distant (e.g., from other rooms, chimneys). Install alarms in each room for best coverage.
  • Smoke alarms may not warn about fires caused by carelessness (smoking in bed), explosions, escaping gas, improper storage of flammables, overloaded circuits, or arson.
  • Like all electronics, smoke alarms have limitations; one type cannot sense all fire types.
  • This alarm requires batteries to function and has limited service life.

FAQ's

  • How many smoke alarms should I have? Depends on premises architecture and size. Install in every bedroom, outside sleeping areas, and on every level. Place at least 20 feet from combustion appliances and 10 feet from humidity-prone areas to reduce nuisance alarms.
  • When should I test my smoke detectors? At least once every 2-3 months by pressing the test button.
  • How do I test my smoke alarm? Press the test button once. Listen for a loud piercing sound and check for mobile notification if online. If weak, change batteries; if that fails, replace the unit.
  • When should I replace the batteries? Upon receiving a low battery notification on the device or app, or if the device is unresponsive.
  • Why is my smoke alarm beeping without fire/smoke, and how to stop it? Possible causes: residual smoke, dust/fiber in the chamber, or a loose smoke chamber. Clean the chamber for dust/smoke issues.
  • Can I interconnect my smoke detector? No, this is a standalone unit.

Warranty

Honeywell International India Pvt Ltd warrants this product against manufacturing defects for 12 months from the purchase date. This warranty is non-transferable and applies only to the first owner purchasing from authorized dealers.

  • Warranty is valid with a purchase invoice and serial/ID number. Service may be declined if documents are incomplete or tampered with.
  • Warranty excludes damage from improper installation, tampering, incorrect batteries, accidents, lightning, water ingress, fire, power fluctuations, physical shock, or external causes beyond normal operation.
  • Honeywell is not liable for incidental, consequential, special, punitive, or indirect damages (loss of profits, data, etc.). Aggregate liability is limited to the product's purchase price.
  • Warranty is not valid outside of India.

For more information:

Website: www.honeywellbuildings.in

Call: 1800-103-4761

Email: hbt.mms@honeywell.com

Address: Honeywell HBT India Buildings, Unitech Trade Center, 5th Floor, Sector-43, Block C, Sushant Lok, Phase - I, Gurgaon - 122 002.

Models: FDC-100 Wireless Smoke Detector, FDC-100, Wireless Smoke Detector, Smoke Detector, Detector

PDF preview unavailable. Download the PDF instead.

B1McfwlnekL CorelDRAW X6 3-Heights™ PDF Optimization Shell 6.3.1.5 (http://www -tools.com)

Related Documents

Preview Honeywell X-Series Battery Powered Fire Alarms: Installation and Operating Instructions
Comprehensive guide to Honeywell's X-Series battery-powered fire alarms (XH100, XS100, XS100T), covering installation, operation, testing, specifications, safety precautions, and emergency procedures.
Preview SK-Duct Air Duct Smoke Detector Installation and Maintenance Manual | Honeywell
Comprehensive installation and maintenance guide for the Honeywell SK-Duct Air Duct Smoke Detector. Covers specifications, installation procedures, wiring, testing, and troubleshooting.
Preview Honeywell SK-DUCT-W Duct Smoke Detector: Installation and Maintenance Manual
Comprehensive installation and maintenance guide for the Honeywell SK-DUCT-W Duct Smoke Detector, covering specifications, installation procedures, wiring, testing, cleaning, sensor replacement, and optional accessories.
Preview Honeywell VISTA-20P Alarm System Integration with SmartThings and Smoke Detectors
A comprehensive guide detailing the integration of a Honeywell VISTA-20P alarm system with Konnected.io and Samsung SmartThings. It covers system configuration, panel programming, smart home device setup, and the integration of 110V smoke detectors using a First Alert RM4 relay and an Altronix 6062 timer module.
Preview Notifier FSP-951-SELFT Intelligent Photoelectric Self-Test Smoke Sensor Installation and Maintenance Instructions
Detailed installation and maintenance instructions for the Notifier FSP-951-SELFT Intelligent Photoelectric Self-Test Smoke Sensor, covering specifications, wiring, testing, and cleaning procedures.
Preview Honeywell VISTA-20P Home Security System Integration with SmartThings
Guide to integrating a Honeywell VISTA-20P alarm system with Samsung SmartThings, including setup, configuration, and component details for smoke detector integration. This document details the system configuration, programming steps, and integration with smart home platforms.
Preview Honeywell FAAST Aspirating Smoke Detection Applications Guide
Comprehensive guide to Honeywell's FAAST Aspirating Smoke Detection (ASD) systems, detailing principles, applications in data centers, telecommunications, clean rooms, and duct monitoring, along with installation and maintenance best practices, adhering to EN 54-20, NFPA, and BS 6266 standards.
Preview Honeywell Silent Knight SK-ZONE Module Datasheet - Addressable Fire Alarm Interface
Technical datasheet for the Honeywell Silent Knight SK-ZONE Module, an addressable two-wire interface module for fire alarm control panels. Features include compatibility, specifications, and installation details.