Quick Start Guide

08D7M

Speco Technologies

Welcome

Thank you for purchasing this network camera! This owner's manual is designed to be a reference tool for your system. Please read this manual carefully before operating the unit and retain it for future reference. Should you require any technical assistance, contact Speco Technologies Tech Support at 1-800-645-5516

Important Safeguards and Warning

  1. Electrical safety

    All installation and operation here should conform to local electrical safety codes. Use a certified/listed 12VDC Class 2 power supply only. Please note: Do not connect two power supplying sources to the device at the same time; it may result in device damage! The product must be grounded to reduce the risk of electric shock. Improper handling and/or installation could run the risk of fire or electrical shock.

  2. Environment

    Heavy stress, violent vibration or exposure to water is not allowed during transportation, storage and installation. This product should be installed in a cool, dry place away from direct sunlight and heat sources. Do not install the product in extreme temperature conditions. Do not expose the camera to electromagnetic radiation. Otherwise it may result in CMOS sensor failure. Do not block any ventilation openings. Do not allow water and liquid intrusion into the camera.

  3. Operation and Daily Maintenance

    Please shut down the device and then unplug the power cable before you begin any maintenance work. Do not touch the CMOS sensor optic component. You can use a blower to clean the dust on the lens surface. Always use the dry soft cloth to clean the device. If there is too much dust, use a cloth dampened with a small quantity of neutral detergent. Finally use the dry cloth to clean the device. Please use a professional optical cleaning method to clean the enclosure. Improper enclosure cleaning (such as using cloth) may result in poor IR functionality and/or IR reflection. The grounding holes of the product are recommended to be grounded to further enhance the reliability of the camera. Dome cover is an optical device, please don't touch or wipe cover surface directly during installation and use, please refer to the following methods if dirt is found: Stained with dirt: Use oil-free soft brush or hair dryer to remove it gently. Stained with grease or fingerprint: Use oil-free cotton cloth or paper soaked with alcohol or detergent to wipe from the lens center outward. Change the cloth and wipe several times if it is not clean enough.

Warning

This camera should be installed by qualified personnel only. All the examination and repair work should be done by qualified personnel. Any unauthorized changes or modifications could void the warranty.

Statement

This guide is for reference only. Product, manuals and specifications may be modified without prior notice. Speco Technologies reserves the right to modify these without notice and without incurring any obligation. Speco Technologies is not liable for any loss caused by improper operation.

Note:

Before installation, check the package and make sure that all components are included. Contact your rep or Speco customer service department immediately if something is broken or missing in the package.

1 Package

The package includes the following items:

2 Overview

The camera features the following ports and components:

Alarm Connections: The alarm interface has four terminals:

* It is recommended to install the security cap for outdoor installations. ?

* DC 12V power supply is not required if a PoE switch or injector is used to power the camera.

Connecting Network Cable

Follow these steps to connect the network cable:

  1. Loosen the nut from the main element.
  2. Run the network cable (without RJ 45 connector) through both elements. Then crimp the cable with RJ 45 connector.
  3. Connect the cable to the hermetic connector. Then tighten the nut and the main cover.

3 Installation

Before you start: Please make sure that the wall or ceiling is strong enough to withstand three times the weight of the camera.

  1. Open the upper cover of the junction box. Then install the junction box onto the wall by using the screws provided.
  2. Route the cables through the cable hole (e.g., side conduit cabling). Then reinstall the upper cover to the junction box.
  3. Loosen the screws to open the lower dome and then loosen the lock screw to remove the mounting base.
  4. Install the mounting base onto the junction box. Then connect the cables and fix the dome to the mounting base with the lock screw.
  5. Three-axis Adjustment: Before adjustment, preview the image of the camera on a monitor and then adjust the camera according to the following angles to get an optimum view:
    • Tilt: 0°~77°
    • Pan: 0°~360°
    • Rotation: 0°~360°
  6. Install the lower dome back to the camera and fix it with the screws.

4 Web Operation and Login

IP Scanner can search for the device on the local network.

Operation

  1. Make sure that the camera and the PC are connected to the same local network. The camera is set to DHCP by default.
  2. Install IP Scanner from the CD and run it after installation.
  3. In the device list, you can view the IP address, model number, and MAC address of each device. Select the applicable device and double click to open up the web viewer. You can also manually enter the IP address in the address bar of the web browser.

The login interface is shown above. Default user name is admin and password is 1234. After logging in, follow directions to install applicable plugins.

Models: O8D7M, IP Dome Camera, O8D7M IP Dome Camera, Dome Camera

File Info : application/pdf, 9 Pages, 2.54MB

PDF preview unavailable. Download the PDF instead.

O8D7M-Quick-Start-Guide Corel PDF Engine Version 14.0.0.653

Related Documents

Preview Speco Technologies O4P4 Quick Start Guide
Quick start guide for the Speco Technologies O4P4 IP camera, covering installation, network connection, and web operation. Includes warnings, package contents, overview, and login details.
Preview Speco Technologies 04VT1M Quick Start Guide: Installation and Operation
A comprehensive quick start guide for the Speco Technologies 04VT1M IP Turret Camera, detailing installation steps, package contents, and initial web operation.
Preview Speco Technologies 05D2 Quick Start Guide
A concise guide for installing and operating the Speco Technologies 05D2 network camera, including setup, connections, and web interface access.
Preview Speco Technologies 04D6 IP Dome Camera Quick Start Guide
Quick start guide for the Speco Technologies 04D6 IP Dome Camera, covering installation, setup, and web operation. Includes warnings, package contents, overview, and login instructions.
Preview Speco Technologies 08VT2 Quick Start Guide
This guide provides essential information for the Speco Technologies 08VT2 network camera, covering safety precautions, package contents, device overview, installation steps, and web-based operation for setup and configuration.
Preview Speco Technologies 08LMST1 Network Camera Quick Start Guide
A quick start guide for the Speco Technologies 08LMST1 network camera, detailing installation steps, overview of features, and web operation and login procedures. Includes important safety warnings and package contents.
Preview Speco Technologies 04BDD1M Network Camera Quick Start Guide
Get started quickly with the Speco Technologies 04BDD1M network camera. This guide provides essential information on installation, connection, and basic operation for your surveillance system.
Preview Speco Technologies 04T7N Network Camera Quick Start Guide
This guide provides instructions for setting up and operating the Speco Technologies 04T7N network camera, covering installation, network connection, and web interface access.