1 Introduction

The control unit has been designed for use with rolling shutters and blinds. This product can control single-phase 230 Vac alternating current motors, with a maximum power of 500W, equipped with electric limit switches. It is pre-wired.

This control cabinet contains a radio receiver for remote control by transmitters (CLARUS and B.RO) and for managing wireless climatic sensors KAIROS (light, wind, rain, and temperature), KAIROS DUO (light and wind), and AXEM (wind and inclination), all with radio frequency transmission at 433.92 MHz.

The control unit has been made in a reduced size to be installed inside the housings of rolling shutters or externally (depending on orientation).

MicroCap 16 can control a motor with a maximum authorized opening time of 2.5 minutes. The relays are activated by an "OPEN" or "CLOSE" command from the transmitter and are deactivated by pressing any key during movement. For example, if the shutter/blind is stopped by a limit switch, the control unit remains in the shutter opening state until it reaches 2.5 minutes. During this time interval, two "CLOSE" commands will be necessary to close the shutter (as it will have to pass through the STOP state).

2 Installation

For outdoor installation, it is essential to respect the orientation of the control unit. The correct installation is with the power and motor cables exiting from the bottom, as shown in the box.

Correct Installation: Diagram shows the control unit box with power and motor cables exiting downwards.

Incorrect Installation: Diagram shows the control unit box with cables exiting upwards, marked with a red cross.

3 Configuration and Electrical Connections

Wiring Diagram:

Connections to motor wires:

Attention: The open/close functions depend on the motor orientation. If an opening command corresponds to the shutter closing, it will be necessary to invert the brown (close) and black (open) wires.

4 Transmitter Learning

4.1 Transmitter Learning via the Control Unit Button

The control unit can be controlled by all remote controls from the B.RO 2/4WN, B.RO WALL, and CLARUS series.

Learning Process:

  1. Press and release the learning button on the board; the control unit emits 3 beeps.
  2. Press a button on the transmitter to be memorized. The control unit automatically memorizes all buttons and emits a long beep.
  3. Release the remote control button; the control unit emits 4 beeps.

If no signal is transmitted within 15 seconds, the control unit automatically exits learning mode (4 beeps).

Note: For CLARUS series, buttons on the right and left are not present.

4.2 Learning with a Memorized Transmitter

Attention: Do not use the following procedure in the presence of multiple active control units, as memory opening would occur for all devices in which the transmitter is memorized. In this case, disconnect the power from unaffected control units.

  1. Press and release the hidden button of a B.RO transmitter or transmit the menu option "M" of an already memorized CLARUS transmitter (*); the control unit emits 3 beeps.
  2. Press a button on the transmitter to be memorized. The control unit automatically memorizes all buttons and emits a long beep.
  3. Release the remote control button; the control unit emits 4 beeps.

If no signal is transmitted within 15 seconds, the control unit automatically exits learning mode (4 beeps).

(*) For CLARUS transmitter menu functions, refer to the product instructions.

5 Climatic Sensors

5.1 Climatic Sensor Learning

  1. Press and release the learning button on the board; the control unit emits 3 beeps.
  2. Press the button on the sensor; the control unit emits a long beep.
  3. Release the sensor button; the control unit emits 4 beeps.

If no signal is transmitted within 15 seconds, the control unit automatically exits learning mode (4 beeps).

Once memorized, it is possible to test the transmission by pressing the button on the sensor. The control unit emits an audible signal until the button is released.

NOTE: The control unit allows learning only one radio sensor. Memorizing a second sensor automatically deletes the first one memorized.

5.2 Motor Direction Check During Alarm

This procedure is necessary to verify correct motor wiring, so that during an alarm the automation closes.

  1. Using a transmitter, move the shutter/blind approximately halfway and stop it.
  2. On the KAIROS sensor used, set the wind trimmer to minimum (TEST) and rotate the sensor blades at a constant speed for a few seconds. On the AXEM sensor used, shake the shutter until the sensor intervenes.
  3. The control unit in alarm will command the shutter/blind to re-close.

If the shutter/blind moves to open, disconnect power to the control unit, invert the motor wires (black and brown), and repeat the test. If the shutter/blind moves to close, wait for complete closure. Press and release the sensor learning button. Follow the sensor instructions for adjustment.

5.3 Deleting a Climatic Sensor

  1. Press and release the learning button on the board; the control unit emits 3 beeps.
  2. Press the button of the already memorized sensor; the control unit emits two long beeps.
  3. Release the sensor button; the control unit emits 4 beeps.

If no signal is transmitted within 15 seconds, the control unit automatically exits learning mode (4 beeps).

5.4 AXEM Sensor Behavior

AXEM sensor alarms are deactivated during the control unit's entire working time, plus an additional 10 seconds. To cancel the waiting time and activate the sensor immediately, press the AXEM device's learning button.

5.5 Light Sensor

The control unit is designed to open the shutter/blind upon the transition from Night to Day, and to close the shutter/blind upon the transition from Day to Night. Furthermore, reopening for light has been integrated, at the end of any alarms (wind or disconnection).

It is possible at any time to disable the light sensor functionalities and thus prevent the automation from moving up or down automatically based on light variations. To disable the light sensor, proceed as follows:

  1. Press and hold a button on an already learned transmitter (for at least 8 seconds). The control unit emits 2 beeps to indicate sensor deactivation or 3 beeps to indicate sensor reactivation.
  2. Release the transmitter button.

5.6 Control Unit Behavior During Alarms (Wind, Rain, Snow, Disconnection)

The presence of an alarm, in addition to instantly closing the shutter/blind, will lock the operation of the remote controls for:

Snow detection (snow alarm) occurs differently depending on the type of sensor used:

If radio communication between the sensor and the control unit is absent for more than 4 minutes, the control unit will completely close the shutter and remain in the disconnection alarm state until the sensor reconnects. The alarm condition is indicated by 4 beeps upon receiving a user command.

During an alarm state, radio learning is possible, but movements are not possible until the device exits the alarm state. The control unit signals the alarm state upon receiving a user command.

6 Reset

  1. Press and hold the learning button. After 7 seconds, the device emits a continuous beep.
  2. Release the learning button; the control unit emits 5 beeps.

All transmitters have been erased, and settings have been restored to factory defaults.

7 Product Disposal

This product is an integral part of the automation system and as such must be disposed of with it. As with installation operations, at the end of this product's life, dismantling operations must also be carried out by qualified personnel. This product is composed of different types of materials: some can be recycled while others must be disposed of. Inquire about the recycling or disposal systems provided by the regulations in force in your territory for this product category.

ATTENTION! – some parts of the product may contain polluting or dangerous substances which, if released into nature, could have harmful effects on the environment and human health. As indicated by the symbol shown, it is forbidden to dispose of this product with household waste. Therefore, proceed with "selective collection" for its disposal in accordance with the methods provided by the regulations in force in your territory, or return the product to the seller when purchasing a new equivalent product.

ATTENTION! – local regulations may provide for heavy penalties in case of improper disposal of this product.

Warranty

The manufacturer's warranty is valid according to the law from the date stamped on the product and is limited to the free repair or replacement of parts recognized as defective due to lack of essential material quality or manufacturing defect. The warranty does not cover damage or defects due to external agents, lack of maintenance, overload, natural wear and tear, incorrect product choice, assembly error, or other causes not attributable to the producer. Tampered products will not be guaranteed or repaired.

The data provided is purely indicative. No responsibility can be attributed for range reductions or malfunctions due to environmental interference. The producer's liabilities for damages caused to persons due to incidents of any nature resulting from our defective products are solely those covered by Italian law.

Models: 1622108 Control Center for Blinds and Shutters Wireless Sensor, 1622108, Control Center for Blinds and Shutters Wireless Sensor, Center for Blinds and Shutters Wireless Sensor, Blinds and Shutters Wireless Sensor, Shutters Wireless Sensor, Wireless Sensor, Sensor

File Info : application/pdf, 4 Pages, 846.41KB

PDF preview unavailable. Download the PDF instead.

1622108 FRA MICROCAP16

References

Adobe PDF Library 15.0 Adobe InDesign 15.0 (Windows)

Related Documents

Preview Allmatic MicroCap 16: Control Unit for Roller Shutters and Blinds
Comprehensive guide to the Allmatic MicroCap 16 control unit for roller shutters and blinds, including installation, configuration, and operation with wireless sensors and remote controls.
Preview ALLMATIC KAIROS Wireless Climate Sensor Installation and User Manual
Comprehensive guide for the ALLMATIC KAIROS wireless sensor, detecting light, wind, rain, and temperature. Includes installation, functionality, adjustment, maintenance, troubleshooting, and compatibility with ALLMATIC awning control units.
Preview Manuale Utente Sensore Climatico Wireless ALLMATIC KAIROS
Manuale utente dettagliato per il sensore climatico wireless ALLMATIC KAIROS, che copre installazione, funzionalità, regolazioni per luce, vento, pioggia e temperatura, manutenzione e risoluzione dei problemi per sistemi di automazione per tende da sole.
Preview Centrale PROXIMA S: Motor Control Unit for Rolling Shutters
Instructions and technical specifications for the PROXIMA S control unit, designed for single-motor rolling shutters. Covers installation, transmitter programming, and advanced configuration.
Preview Proxima M Control Unit for Rolling Shutters - User Manual
Instructions and technical specifications for the Proxima M control unit, designed for single-motor rolling shutters and blinds. Covers installation, configuration, transmitter learning, and advanced settings.
Preview CLARUS Series Transmitters: CLARUS I, VI, XII User Manual
Comprehensive guide for CLARUS I, VI, and XII series transmitters, detailing features, configuration, battery replacement, technical specifications, and disposal information. Learn about their variable coding, group function, and menu options for enhanced home control.
Preview Allmatic AV & AV1 Control Unit with Extractible Memory - User Manual
This manual provides detailed instructions for the Allmatic AV and AV1 control units, covering installation, configuration, programming of functions like remote control learning, automatic closure, pedestrian mode, electric lock, and advanced jumper settings. Includes technical specifications and safety warnings.
Preview Allmatic B.RO X40 DISPLAY Ricevitore Rolling Code a 4 Canali - Manuale Tecnico
Manuale tecnico completo per il ricevitore Allmatic B.RO X40 DISPLAY. Copre installazione, configurazione, apprendimento trasmettitori, gestione menu, modalità operative, specifiche tecniche e risoluzione problemi.