installation guide for legrand models including: LMGS-150-PB, LMPB-100, LMGS-150-PB DLM 5.7 Graphic Switch Touchscreen, LMGS-150-PB, DLM 5.7 Graphic Switch Touchscreen, 5.7 Graphic Switch Touchscreen, Graphic Switch Touchscreen, Switch Touchscreen, Touchscreen
DLM 5.7" Graphic Switch Touchscreen with LMPB-100, Black
File Info : application/pdf, 4 Pages, 681.11KB
DocumentDocumentWattstopper ® DLM 5.7" Graphic Switch with LMPB-100 No. 33736 07/25 rev. 3 Installation Instructions · Instructions d'Installation · Instrucciones de Instalación Catalog Number · Le Numéro de Catalogue · Número de Catálogo: LMGS-150-PB Country of Origin: Made in China · Pays d'origine: Fabriqué en Chine · País de origen: Hecho en China SPECIFICATIONS DESCRIPTION AND OPERATION The LMGS-150 graphic switch is a native DLM wired device with a 5.7" capacitive touch LCD display that enables simple control of lights, shades, and scenes. The LMGS-150 is compatible with wired DLM rooms, LMCP panels, and LMZC-301 zone controllers and connects to the DLM local network using a single Cat5e cable for communication and 24VDC low voltage power. For ease of installation, each LMGS-150 includes a plenum rated KO mount power supply (LMPB-100). Wattstopper Plug n Go TM (PnG) automatically configures the user interface with default screen settings without requiring any programming. The device is fully programmable and field upgradeable using LMCS-100 5.13 or later. Voltage .................................................................................. 24VDC Current Consumption ............................................................150 mA Power Supply .................DLM Power Booster (LMPB-100 included) Display............................5.7" Diagonal, Full Color, High Resolution, ...................... TFT Capacitive Touch LCD, 1440x720, 282ppi , ......................................................................18:9 Aspect Ratio Mounting Orientation ............................................................. Portrait Connection to the DLM Local Network..........................1 RJ-45 Port DLM Local Network characteristics: Low voltage power provided over Cat 5e cable (LMRJ). Max current: 800mA. Max total cable: 1000' Cable added per device: 150'. Max loads: 64. Max communicating devices: 24 if all power supplies are 10X-Series, 48 otherwise. Max 10X-Series power supplies: 5. Communications.....1 USB-C Programming port (for field upgrades) Finishes ............................................. Glass, Aluminum Alloy, Plastic Operating Temperature ........................ 32°F to 122°F (0°C to 50°C) Storage Temperature..........................-4°F to 140°F (-20°C to 60°C) Operating Humidity............................... 5% to 85% Non-condensing Weight .................................................................................... 6.4 oz. Certifications............................................................CE, FCC, RoHS Warranty ........................................................................... Five years CONNECTIVITY Ceiling Mount Sensor DLM Local Network Low Voltage LMRJ Cables Line Voltage Red wire to Load Room Controller Line/Hot Black wire Neutral White wire Load Switched with 0-10 Volt control Dimming Ballast LED Driver, etc. Deep J-Box 0-10V Class 1 Pink and Purple wires to Load LMPB-100 The LMGS-150-PB-x comes with an LMPB-100. LMGS-150 Maximum cable distance between the LMGS-150 and the LMPB-100 is 100 ft. NOTE: After a power loss event, the LMGS-150 will automatically restart when power is restored to the IRB local network. The LMGS-150 takes approximately 90 seconds to restart before the user interface is available to control loads. After a power loss all loads will return to their previous state by default. By using LMCS, loads can be individually configured to turn On or Off. CAUTION: TO CONNECT A COMPUTER TO THE DLM LOCAL NETWORK USE THE LMCI-100. NEVER CONNECT THE DLM LOCAL NETWORK TO AN ETHERNET PORT IT MAY DAMAGE COMPUTERS AND OTHER CONNECTED EQUIPMENT. FRONT AND BACK VIEW USB C Port Top View Power Reset Buttons (Recessed) RJ-45 jack for connection to DLM Local Network Front View Rear View Side View MOUNTING The LMGS-150 Graphic Switch is designed to mount onto a standard single-gang junction box or low voltage ring, using the supplied mounting plate with security screw. The LMGS-150 then attaches to the mounting plate via tabs and slots. The mounting plate includes screw holes for both U.S. (83.5mm) and International (60mm) J-Boxes. Minimum recommended junction box depth is 1 -7/8". Recommended mounting height per ADA 2010 Design Standards is no higher than 48" above finished floor. WARNING: Do not install to cover a junction box having Class 1, 3, or Power and Lighting Circuits. Attach Mounting Plate to JBox Attach LMGS-150 to Mounting Plate Screw holes for U.S. JBoxes Connect LMRJ cable Screw holes for International JBoxes Securing screw Insert tabs into slots, then slide down to lock in place. Secure the LMGS-150 to the mounting plate by tightening the screw 2 PLUG N' GO OPERATION (PNG) The DLM Graphic Switch supports PnG to automatically create default screens and graphical buttons based on the load types in the room. All supported lighting loads are bound to lighting buttons and sliders on the Home, Lights, and Scenes pages. All supported shade loads are bound to shading buttons on the Home and Shades pages. Tap the Hamburger menu to navigate between the available screens. NOTE: All user interface customization is done using LMCS-100. Visit www.legrand.us/wattstopper/software for more information. NOTE: LMCP panels and LMZC-301 zone controllers do not support PnG. PROGRAMMING OVERVIEW The LMGS-150 is programmed by authorized technicians using the LMCS-100 software version 5.13 or later. Programming steps are outlined in the LMCS user guide. USB NOTE: The USB-C port is required when updating the LMGS APP UI version. The USB-C cable must support power and data. All other programming can be done using the LMCI-100. NOTE: The LMCT-100-2 wireless configuration tool does not support the LMGS-150. TROUBLESHOOTING The LMGS-150 does not operate as expected. The LMGS device does not power on The user interface is displaying "No loads Found" The wrong loads are controlled The user interface isn't responding 1. Check to make sure the RJ45 is fully plugged into the LMGS and LMPB. 2. Test the cable to make sure the RJ45 terminations are correct. 3. Connect a known good device to the DLM local network to verify power. 1. LMGS-150 does not support PnG when connected to an LMCP panel or LMZC-301. 2. When LMGS is connected to a wired room confirm check to make sure PnG is not locked. 1. Use LMCS-100 to configure the correct button load bindings. 1. Locate the recessed reset button on the right side of the unit, press and release to power cycle the unit. 3 FCC REGULATORY STATEMENTS This equipment has been tested and found to comply with the limits for a Class A digital device, pursuant to part 15 of the FCC Rules. These limits are designed to provide reasonable protection against harmful interference when the equipment is operated in a commercial environment. This equipment generates uses, and can radiate radio frequency energy and, if not installed and used in accordance with the instruction manual, may cause harmful interference to radio communications. Operation of this equipment in a residential area is likely to cause harmful interference in which case the user will be required to correct the interference at his own expense. WARRANTY INFORMATION INFORMATIONS RELATIVES À LA GARANTIE INFORMACIÓN DE LA GARANTÍA Wattstopper warranties its products to be free of defects in materials and workmanship for a period of five (5) years. There are no obligations or liabilities on the part of Wattstopper for consequential damages arising out of, or in connection with, the use or performance of this product or other indirect damages with respect to loss of property, revenue or profit, or cost of removal, installation or reinstallation. Wattstopper garantit que ses produits sont exempts de défauts de matériaux et de fabrication pour une période de cinq (5) ans. Wattstopper ne peut être tenu responsable de tout dommage consécutif causé par ou lié à l'utilisation ou à la performance de ce produit ou tout autre dommage indirect lié à la perte de propriété, de revenus, ou de profits, ou aux coûts d'enlèvement, d'installation ou de réinstallation. Wattstopper garantiza que sus productos están libres de defectos en materiales y mano de obra por un período de cinco (5) años. No existen obligaciones ni responsabilidades por parte de Wattstopper por daños consecuentes que se deriven o estén relacionados con el uso o el rendimiento de este producto u otros daños indirectos con respecto a la pérdida de propiedad, renta o ganancias, o al costo de extracción, instalación o reinstalación. No. 33736 07/25 rev. 3 © Copyright 2025 Legrand All Rights Reserved. © Copyright 2025 Tous droits réservés Legrand. © Copyright 2025 Legrand Todos los derechos reservados. 800.879.8585 www.legrand.us/wattstopper
![]() |
Legrand Wattstopper DLM 5.7" Graphic Switch LMGS-150 Detailed information on the Legrand Wattstopper DLM 5.7" Graphic Switch (LMGS-150), including features, specifications, operation, and applications for controlling lights, shades, and scenes in commercial spaces. |
![]() |
Wattstopper LMDC-100 DLM Dual Technology Occupancy Sensor | Quick Start Guide Quick start guide for the Wattstopper LMDC-100 DLM Dual Technology Ceiling Mount Occupancy Sensor. Provides specifications, installation, connectivity, mounting, pre-set operations, and troubleshooting information. |
![]() |
Wattstopper LMRC-111/112 DLM Room Controller Quick Start Guide Quick start guide for Wattstopper DLM Single/Dual Relay Room Controllers (LMRC-111, LMRC-112) with 0-10V dimming. Covers installation, wiring, Plug n' Go operation, and safety for lighting control systems. |
![]() |
Legrand Wattstopper Digital Lighting Management Low Voltage Switches Quick Start Guide Quick start guide for Legrand Wattstopper Digital Lighting Management Low Voltage Switches (v3), including installation, operation, and troubleshooting for models LMSW-101, LMSW-102, LMSW-103, LMSW-104, and LMSW-108. |
![]() |
DLM Dashboard Installation Guide: WSL, Docker, ESE, and Niagara Workbench Setup Step-by-step instructions for installing and configuring WSL, Docker, and ESE for DLM Dashboard, including integration with Niagara Workbench. Essential for setting up building automation systems. |
![]() |
Legrand Wattstopper LMJA-8125/LMJA-8300 Network Controller Installation Guide Official installation instructions for the Legrand Wattstopper LMJA-8125 and LMJA-8300 network controllers. This guide covers setup, wiring, and operational procedures for DLM and BACnet systems, leveraging the Tridium Niagara platform. |
![]() |
Wattstopper DW-311/DW-311-347 Dual Technology Wall Switch Occupancy Sensor Installation Instructions This document provides detailed installation instructions for the Wattstopper DW-311 and DW-311-347 Dual Technology Wall Switch Occupancy Sensors. It covers wiring, setup, features, and troubleshooting for these advanced PIR and ultrasonic sensors. |
![]() |
Wattstopper DW-311/DW-311-347 Dual Technology Occupancy Sensor Installation Guide Comprehensive installation guide for Wattstopper DW-311 and DW-311-347 Dual Technology 0-10 Volt Wall Switch Occupancy Sensors. Covers features, specifications, wiring, setup, multi-way functionality, advanced settings, and troubleshooting. |