OKIN CB1522 Control Box: Product Function Instruction

Brand: OKIN

Document Number: CB1522

Version: 1.1

Date: 2017-08-23

Author: Kyle

Document ID: CB.15.22.01

1. Electrical Configuration Diagram

The diagram illustrates the electrical connections for the OKIN CB1522 control box. Key components and their interconnections are as follows:

  • AC Cable: Connects to the SMPS (Switching Mode Power Supply).
  • SMPS: Connects to a DC Extension Cable.
  • DC Extension Cable: Connects to a USB Transformer Box.
  • Control Box: The central unit.
  • Connections from Control Box:
    • Head Motor / Foot Motor: Connected via a patch cord.
    • Massage Motor: Connected via a patch cord.
    • USB Charger Port: For charging devices.
    • Under Bed Light: For illumination.
    • Sync Cable (Optional): For synchronization with other accessories.

2. Function Picture

The control box, model CB1522, is shown in the accompanying image. The top surface features several control buttons and indicators:

  • Buttons: POWER, USB, SYNC, PAIR.
  • Indicators: Labels for HEAD MOTOR, FOOT MOTOR, MASSAGE, and MFP are present.
  • Branding: The OKIN logo is prominently displayed in the center.

1. Process of Test

1.1. HEAD MOTOR

Connection: Connect the head actuator to the control box.

Operation: Control is managed via the remote.

  • Pressing the 'head up' button on the remote extends the head actuator. Releasing the button stops the movement.
  • Pressing the 'head down' button on the remote retracts the head actuator. Releasing the button stops the movement.

These functions are activated solely by pressing the corresponding buttons on the remote.

1.2. FOOT MOTOR

Connection: Connect the foot actuator to the control box.

Operation: Control is managed via the remote.

  • Pressing the 'foot up' button on the remote extends the foot actuator. Releasing the button stops the movement.
  • Pressing the 'foot down' button on the remote retracts the foot actuator. Releasing the button stops the movement.

These functions are activated solely by pressing the corresponding buttons on the remote.

1.3. Massage

Connection: Connect to the head and foot massage units.

Operation: Control is managed via the remote.

  • Pressing the 'head massage +' button increases the massage intensity by one level.
  • Pressing the 'head massage -' button decreases the massage intensity by one level.

These functions are activated solely by pressing the corresponding buttons on the remote.

1.4. Test for Underbed Light

Operation: Clicking the 'underbed light' button on the remote toggles the underbed light on or off. The status changes with each click.

This function is activated solely by pressing the corresponding button on the remote.

1.5. SYNC Port

Connect with other Control Boxes or accessories using the SYNC port.

1.6. Power LED & PAIRING LED

The PAIRING LED on the control box is blue when powered. The POWER LED is green.

1.7. Power

Connect to a 29V DC power source.

1.8. RESET Button

Pressing and holding the RESET button on the remote causes both the Head and Foot actuators to move to their lowest position.

1.9. Pair Function

Initiating Code Pairing:

  • Double-click the RESET button on the remote. The control box's pairing LED will turn on, indicating it has entered pairing mode.
  • Press and hold the PAIRING LED button on the remote. The backlight of the remote's pairing LED will flash, and the remote will enter code pairing mode.

Successful Pairing: Indicated when the remote's pairing LED backlight stops flashing and the control box's pairing LED turns off.

Troubleshooting: If pairing fails, repeat all the above processes.

1.10. FLAT Function

Operation: Press and release the FLAT button on the remote. The head and foot actuators move to their lower position. If an actuator is free, a single press can also turn off the vibration motor and indicator light. Movement stops when any button is pressed.

This function is activated solely by pressing the corresponding remote button.

1.11. ZERO G Position Function

Operation: Press and release the ZERO G button on the remote. The head and foot actuators move to their preset memory positions. Movement stops when any button is pressed.

This function is activated solely by pressing the corresponding remote button.

1.12. Bluetooth Function

Utilize the dedicated APP to establish a Bluetooth connection for controlling the control box. For comprehensive instructions, consult the "ORE_BLE_USER MANUAL".

FCC Warning

Users are cautioned that any changes or modifications not expressly approved by the party responsible for compliance could void the user's authority to operate the equipment. This device complies with Part 15 of the FCC Rules. Operation is subject to the following two conditions:

  1. This device may not cause harmful interference.
  2. This device must accept any interference received, including interference that may cause undesired operation.

ISED RSS Warning

This device complies with Industry Canada licence-exempt RSS standard(s). Operation is subject to the following two conditions:

  1. This device may not cause interference.
  2. This device must accept any interference, including interference that may cause undesired operation of the device.

French Translation: Le présent appareil est conforme aux CNR d'Industrie Canada applicables aux appareils radioexempts de licence. L'exploitation est autorisée aux deux conditions suivantes : (1) l'appareil ne doit pas produire de brouillage, et (2) l'utilisateur de l'appareil doit accepter tout brouillage radioélectrique subi, même si le brouillage est susceptible d'en compromettre le fonctionnement.

Models: CB1522, 2AVJ8-CB1522, 2AVJ8CB1522, CB1522 Control Box, Control Box

PDF preview unavailable. Download the PDF instead.

GetApplicationAttachment.html?id=5418333 Wayne Cao;jarek Adobe PDF Library 17.11.238

Related Documents

Preview OKIN CB.2542 Control Box: Product Function Instruction
Detailed instructions and functional overview for the OKIN CB.2542 Control Box, covering actuator control, massage functions, LED indicators, and pairing procedures. Includes FCC and ISED compliance statements.
Preview OKIN CB3433A Control Box Function Instruction and Operation Guide
This document provides a detailed function instruction for the OKIN CB3433A control box, a component for adjustable furniture systems manufactured by OKIN, a Phoenix Mecano Company. It outlines the electrical configuration, describes the control box interface, and explains the operation of various actuators (head, foot, lumbar), massage motors, and underbed RGB lighting. The guide also covers LED indicators, pairing procedures, connectivity options (SYNC, USB, UART), power requirements, and includes FCC and ISED RSS regulatory warnings. Written by Jarek from the R&D Division.
Preview OKIN RF401B System Instruction Manual
This document provides system instructions for the OKIN RF401B remote control, detailing the function of each button and its operation.
Preview OKIN RF399A Remote Control System Instruction
This document provides system instructions for the OKIN RF399A remote control, detailing the function of each button for operating an adjustable bed.
Preview OKIN JLDK-18-4 Wireless Remote Control System Operating Manual
Comprehensive operating manual for the OKIN JLDK-18-4 wireless remote control system for adjustable beds. Details button functions, setting special positions, wireless pairing, synchronization, system components, and FCC compliance information.
Preview OKIN Refined Electric Technology Remote Control System Operating Manual
This manual provides detailed operating instructions for the OKIN Refined Electric Technology remote control system, covering button descriptions, special position settings, and wireless pairing procedures.