Quest XPointer Scuba Tector

This document provides operational guidance for the Quest XPointer Scuba Tector, an underwater metal detector.

Structure

The Quest Scuba Tector features the following components:

Quick Start

Snorkeling Mode (0-10M Depth)

Power On/Off (Default): Press the Power button once to turn the device on. Press it again to turn it off.

Power On/Off (Retune On): Press the Power button once to turn the device on. To turn it off, press and hold the Power button for approximately 15 seconds.

Dive Mode (10-60M Depth)

To enter Dive Mode, hold both the Power and Mode buttons for 2 seconds. The red indication LED will flash 5 times, and the device will vibrate to confirm entry into Dive Mode. To switch back to shallow water mode, click the Mode button 3 times quickly.

Warning & Warranty Information

Warning: The device has positive buoyancy. Always attach the lanyard to prevent loss.

Register Your Products to Active Warranty

Deteknix Scuba Tector provides a limited warranty to the original purchaser against defects in workmanship and material under normal use for one year from the date of purchase. Exceptions include:

Deteknix is not liable for any further loss, damages, or expenses, including incidental or consequential damages, arising from the sale or use of this product.

Do & Don't

Sensitivity Adjustment

When the device is powered on, press and hold the Mode button, then quickly press the Power button to change the sensitivity level. Levels range from 1 to 4, with 4 being the highest. Each level change is confirmed by an extra beep, with level 4 providing a long beep.

Alarm Modes

When powered on, quickly press the Mode button to cycle through three different alarm modes: Beep only, Vibration only, or Beep and Vibrate.

Losing Mode: If the device detects no alarm or operation for 3 minutes, it will start to beep at a certain frequency. This serves as a reminder to power off the device or to pick it up.

Power Saving Mode: The probe will automatically turn off after 3 minutes of alarming in Losing Mode to conserve battery life.

Programing Features

While powered on, press and hold the Mode button for 4 seconds to enter LED light control programming. The indicator and flashlight will both light up. Quick presses of the Mode button allow you to switch between four modes: indicator only, flashlight only, all off, or all on.

Tuning Function: Under Expert Mode, a quick press of the Power button activates or deactivates the retune function.

Retrieve Target

Scanning: Swing the detector in an overlap style.

Pinpointing: Use the side coil to pinpoint the target's exact location.

Retune Function: This function is designed for ground balancing in high mineralization conditions or for narrowing down the target position. The Xpointer family utilizes Pulse Induction technology, which is unaffected by saltwater or black sand environments. Use this function to get closer to the target. A quick press of the Power button mutes the alarm, allowing you to move until the target is detected again. The function can also be turned off for simpler operation.

Low Battery Indicator

When the probe's flashlight starts to blink at a certain frequency, it indicates that the device needs recharging. You can still use the detector, but its sensitivity may be slightly reduced.

Recharging

It is strongly recommended to use a quality wall charger for recharging. A full charge typically takes about 2-3 hours.

Using a laptop or desktop computer's USB port may provide lower power, resulting in longer charging times.

The probe's blinking light will stop when it is fully charged. The USB cable can remain connected inside the recharge house after charging.

Battery Cap Removal

To remove the battery cap, hold and twist it counter-clockwise to loosen. To re-tighten, hold and twist clockwise. Be cautious of cross-threading the cap and body when tightening.

Maintenance

Cleaning the Device

1. Use tap water or a clean cloth dampened with a mild detergent solution. 2. Wipe the device with the damp cloth. 3. Thoroughly dry the device. Avoid chemical cleaners and solvents, as they can damage plastic components.

The device is waterproof to 60M/200FT and can withstand immersion in water up to 60M/200FT for 30 minutes. After submersion, ensure you wipe the device dry and air dry it before using or charging.

Do not store the device where it may be exposed to extreme temperatures for prolonged periods, as this can cause permanent damage.

O-Ring Care

Clean any dust, sand, or fabric if spotted on the O-ring. Even a tiny grain of sand can cause water ingress.

Apply quality silicone O-ring grease thoroughly.

Change the O-ring at least once a year, using qualified original parts only.

Dive Mode Control

Activation:

Tilt the unit upside down 3 times to activate detection mode (DMA). The red indication LED will blink twice every 3 seconds, indicating it is ready to search.

Deactivation:

Keep the coil held up for 5 seconds to return to No Standby Mode (DMS). The red indication LED will blink once every 3 seconds. The unit remains powered on until it is turned off in snorkeling mode.

Notice: When in deep water, pressing both buttons down simultaneously will automatically switch the detector to dive mode.

PDF preview unavailable. Download the PDF instead.

scuba-tector english Mac OS X 10.12.3 Quartz PDFContext Pages

Related Documents

Preview Quest X5 Metal Detector Quick Start Guide
A quick start guide for the Quest X5 metal detector, covering installation, basic operation, understanding features like discrimination and target ID, detecting techniques, and product care.
Preview Quest AIR Metal Detector Instruction Manual and Warranty
Comprehensive instruction manual and warranty details for the Quest AIR Metal Detector, covering setup, operation, specifications, and troubleshooting.
Preview Quest Q60 Metal Detector Instruction Manual
Comprehensive instruction manual for the Quest Q60 metal detector, covering setup, operation, features, maintenance, and troubleshooting. Includes technical specifications, interface details, and troubleshooting guide.
Preview Quest X5 Metal Detector Quick Start Guide
A quick start guide for the Quest X5 metal detector, covering assembly, operation, detecting techniques, and product care. Features include target ID, multiple programs, and USB charging.
Preview QUEST Q60 Metal Detector: Features and Specifications
Discover the QUEST Q60, a versatile 3-frequency waterproof metal detector for finding jewelry, coins, treasures, and relics. Learn about its advanced features, underwater capabilities, and technical specifications.
Preview Quest Xpointer Pinpointer Instruction Manual
Detailed instructions for operating the Quest Xpointer pinpointer, including battery insertion, power control, sensitivity adjustment, and maintenance.
Preview Quest V80 V60 Metal Detector Instruction Manual
Comprehensive instruction manual for the Quest V80 and V60 metal detectors, covering quick start, assembly, preparation, controls, interface, and advanced features.
Preview Quest Q40 Metal Detector: Quick Start Guide and User Manual
Comprehensive guide for the Quest Q40 metal detector, covering assembly, operation, features like sensitivity and discrimination, troubleshooting, and product care. Learn how to use your Q40 for optimal metal detecting.