Miele PFD 104 SCVi Installation Plan

Model: PFD 104 SCVi

Document Reference: M.-Nr. 11 882 880

Installation Notes

For safe installation and commissioning of the dishwasher, please read this installation plan, the service documentation, the installation sheet, and the operating instructions.

This installation plan includes the dimensions of the appliance, the technical data, and the requirements to be met on site for the installation of the dishwasher.

Installation Requirements

This dishwasher must only be installed and commissioned by the Miele Customer Service Department, a Miele authorised dealer, or a suitably qualified specialist. Installation should only be performed in accordance with valid regulations, relevant standards, and health and safety codes.

Environmental Requirements

Condensate can build up in the area surrounding the dishwasher. Any furniture and fittings in the room must therefore be suitable for purpose. The vapour barrier film supplied protects the worktop from damage caused by steam when the door is opened. Attach the vapour barrier film above the door, underneath the worktop.

Electrical Connection

All work on the electrical connection must be carried out by the Miele Customer Service Department, an authorised Miele dealer, or a qualified electrician.

Plug Connection

The dishwasher should be connected to the electricity supply via a suitably rated plug and socket.

Hard-wired

If the dishwasher is hard-wired to the power supply, a power switch capable of disconnecting the dishwasher at all poles must be installed on site. This power switch must have a contact gap of at least 3 mm. The means for disconnection must be incorporated in the fixed wiring in accordance with the wiring rules AS/NZS 3000. The socket and the power switch must be accessible after the appliance has been installed. An electrical safety test can then easily be carried out, e.g., after any service or maintenance work. The connection cable must be protected from the risk of thermal damage.

Residual Current Device (RCD)

For increased safety, it is recommended to protect the dishwasher with a residual current device (RCD) with a trip current of 30 mA.

Equipotential Bonding

There is a screw connection point for equipotential bonding at the back of the dishwasher. Equipotential bonding should be carried out if possible on site.

Water Connection

The dishwasher must only be connected to fully vented pipework. A brief increase in the water pressure can damage components of the dishwasher.

Water Inlet

The quality of the incoming water must correspond to the drinking water specification of the country in which the dishwasher is being operated. The dishwasher must be connected to the water supply in strict accordance with current local and national requirements (e.g., Plumbing Code of Australia (PCA)). It can be connected to cold or hot water supplies. Connecting the dishwasher to a hot water supply will reduce programme running times. For short programme running times, dynamic water pressure of at least 200 kPa is also required. This appliance must be installed according to AS/NZS 3500.1 and AS/NZS 3500.2. This dishwasher has been supplied with a separate backflow prevention device (dual check valve).

Installation Requirements for Water Inlet:

The dual check valve supplied separately with this product must be installed between the tap and the water inlet hose. Screw the dual check valve onto the tap. Then screw the water inlet hose with the water protection system onto the thread of the dual check valve. Turn on the tap gradually to test for leaks. If there is a leak, the connection might not be on securely, or it may have been screwed on at an angle. Unscrew and reconnect the water correctly before tightening it. If a tap is not available, only a qualified installer may connect the dishwasher to the mains water supply. The tap should remain accessible once the dishwasher has been installed so that the water supply can be shut off whenever the appliance is not in use.

Drain

The dishwasher drain hose should be connected to a separate on-site drainage system for the dishwasher only. If a separate connection is not available, connecting the hose to a dual-chamber siphon is recommended. If the hose is to be fitted directly to the drainage system on site, use the hose clip supplied with the dishwasher. The on-site connector for the drain hose can be adapted to different hose diameters. If the connector extends more than 30 mm into the drain hose, it must be shortened. Otherwise, the drain hose can become blocked.

Lay the drain hose so that it does not kink and is not being subjected to pressure or tension. If the on-site drain connection is situated lower than the guide path for the lower basket rollers in the open door, a siphoning effect during a programme can cause the wash cabinet to empty itself of water. In this case, lay the drain hose with a bend in it so that its highest point is at least level with the guide path for the lower basket rollers.

External Dispensing

An external dispensing module for liquid cleaning agents can be connected to the back of the dishwasher. The dispensing module is available as an optional accessory and is supplied with installation instructions.

Appliance Dimensions and Installation Dimensions

PFD 104 SCVi

Diagram showing top view of appliance installation in cabinetry. Key dimensions indicated: cabinet opening width (greater than or equal to 570 mm), appliance width (600+4 mm), appliance height (greater than or equal to 845 mm), appliance depth (570 mm).

Diagram showing front view of the appliance with door slightly ajar. Key dimensions indicated: minimum front clearance (130 mm), plinth return depth (35 mm), maximum plinth return depth (115 mm), appliance width (598 mm), appliance height range (690-810 mm), appliance height range with plinth (845-910 mm). A magnified view details the plinth area.

Front Panel Dimensions

DimensionUnitValue
Length[mm]690-810
Thickness[mm]16-20
Weight[kg]5-12

Connections

Connections on the Back of the Appliance

Diagram illustrating the rear of the appliance with numbered connection points:

* The dispenser connector is supplied with the dispensing module.

On-site Connections

Diagram showing on-site connection points. Water inlet (5) connects to a tap with a dual check valve (1). Waste water (4) connects to a drain. Electrical connection (1) is shown. External dispensing connection (6) is also indicated. Minimum height requirements are shown: 400 mm for waste water, 500 mm for water inlet, 100 mm for electrical and dispensing connections, and 700 mm for the drain connection point.

External Dispensing

Diagram illustrating the appliance with an external dispensing module connected. Maximum hose length for the dispensing system is shown as 1500 mm.

DescriptionUnitValue
Max. delivery head[m]1.5
Length of dispenser hose, DOS module to suction lance[m]1.8
Length of dispenser hose, back of appliance to DOS module[m]2.8
Length of power cable, back of appliance to DOS module[m]2.8

Place the container on the floor next to the cleaning machine or in an adjacent cabinet. The container must not be placed on top of or above the cleaning machine.

Technical Data

Dimensions and Weights

ParameterUnitValue
Height[mm]845
Height adjustment[mm]65
Width[mm]598
Depth[mm]570
Depth with door open[mm]1205
Max. plinth return[mm]115
Weight[kg]51
Max. floor load[N]1000

Emission Levels

ParameterUnitValue
Sound power level[dB(A) re 1 pW]45
Sound pressure level in the workplace[dB(A)]32.5

Electrical Connection

Standard Electrical Connection

ParameterUnitValue
VoltageAC 230 V
Frequency[Hz]50
Fuse rating[A]10
PlugYes
Power cable length[m]1.7
Power cable cross-section[mm²]3x1
Heat output[kW]1.9
Total rated load[kW]2.1

Possible Voltage Variant

ParameterUnitValue
Voltage3N AC 400 V
Frequency[Hz]50
Fuse rating[A]16
Plug-
Power cable length*[m]1.7
Power cable cross-section[mm²]5x2.5
Heat output[kW]7.1
Total rated load[kW]7.3

* Optional accessory

Water Inlet

ParameterUnitValue
Max. water temperature[°C]60
Max. water hardness[mmol/l]6.5
Max. water hardness[°dH]36
Water connection pressure[kPa]50-1000
On-site threaded union (flat seal)[inches]3/4
Connection hose length[m]1.5

Drain

ParameterUnitValue
Max. water temperature[°C]82
Drain hose length[m]1.5
Max. drain hose length[m]4
Max. delivery head[m]1
Max. transient flow rate[l/min]10
Hose inner diameter[mm]22
On-site hose sleeve (diameter x length)[mm]22 x 30

Operating Conditions

ParameterUnitValue
Ambient temperature[°C]+5 - +40
Relative humidity: Up to 31 °C, maximum[%]80
Relative humidity: Linear decreasing to 40 °C[%]50
Max. altitude above sea level up to[m]4000

Storage and Transportation Conditions

ParameterUnitValue
Ambient temperature[°C]-20 - +60
Relative humidity[%]10-85
Air pressure[hPa]500-1060

Min. Site Access Dimensions (including transport pallet)

DimensionUnitValue
Height[mm]970
Width[mm]670
Depth[mm]670

Contact Information

Miele Australia Pty. Ltd.

ACN 005 635 398
ABN 96 005 635 398

Melbourne:
1 Gilbert Park Drive
Knoxfield, VIC 3180
Telephone: 1300 731 411
Email: service.prof@miele.com.au
Website: www.miele.com.au/professional
Email: sales@miele-professional.com.au

Miele New Zealand Limited

IRD 98 463 631
8 College Hill
Freemans Bay
Auckland 1011
New Zealand
Telephone: 0800 4 MIELE (0800 464 353)
Website: www.miele.com.au/professional
Email: sales@miele-professional.com.au

Miele Global Headquarters

Miele & Cie. KG
Carl-Miele-Straße 29, 33332 Gütersloh, Germany

Alteration rights reserved / Publication date: 2021-07-01

Document Reference: M.-Nr. 11 882 880 / 01

Models: PFD 104 SCVi, Fully Integrated Dishwasher

File Info : application/pdf, 12 Pages, 666.20KB

PDF preview unavailable. Download the PDF instead.

11882880-000-01 11882880-01

References

SCHEMA ST4 ST4 PDF Engine (Build 10.0.2.0)

Related Documents

Preview Miele PFD 104 SCVi Dishwasher Installation Plan
Detailed installation plan and technical data for the Miele PFD 104 SCVi dishwasher, covering dimensions, connections, electrical and water requirements, and operating conditions.
Preview Miele PFD 103 SCI Dishwasher Installation Plan and Technical Data
Comprehensive installation plan and technical specifications for the Miele PFD 103 SCI dishwasher, including dimensions, electrical and water connections, drain requirements, and operating conditions.
Preview Miele PFD 400 - PFD 407 Installation Plan
Comprehensive installation guide for Miele PFD 400 and PFD 407 professional dishwashers, covering electrical and water connections, dimensions, and external dosing.
Preview Miele PFD 104 SCVI XXL Dishwasher: Features, Specifications, and Performance
Detailed specifications and features of the Miele PFD 104 SCVI XXL fully integrated dishwasher, highlighting its 3D MultiFlex Tray, energy efficiency, and advanced drying technology.
Preview Miele PWM 908 DV/DP Washing Machine Installation Plan
Comprehensive installation guide for Miele Professional washing machines, models PWM 908 DV and PWM 908 DP. Covers electrical, water, and drainage connections, dimensions, and safety requirements.
Preview Miele Dishwasher Rebate: Save $200 on Installation
Discover Miele dishwashers and save $200 on installation with this limited-time rebate offer. Learn about qualifying models and terms and conditions for this promotion.
Preview Miele Dishwasher Installation Offer: Save $200
Miele offers $200 off installation with the purchase of select Miele dishwashers. Promotion valid from June 30th to October 5th, 2025. View qualifying models and rebate redemption details.
Preview Miele Dishwasher Installation Offer: Save $200
Miele offers $200 off installation with the purchase of select Miele dishwashers between June 30th and October 5th, 2025. Learn more about qualifying models and how to claim your rebate.