Whirlpool® Dryer with Intuitive Touch Controls - 7.4 cu. ft.
Available Models
White
- WED5605MW - Electric
- YWED5605MW - Electric
- WGD5605MW - Gas
- WED6605MW - Electric
- YWED6605MW - Electric
- WGD6605MW - Gas
Chrome Shadow
- WED5605MC - Electric
- YWED5605MC - Electric
- WGD5605MC - Gas
- WED6605MC - Electric
- YWED6605MC - Electric
- WGD6605MC - Gas
Electrical Requirements
Fuel Type | Electric | Gas |
---|---|---|
Minimum Circuit Amperage Rating | 30 A | 15 A |
Maximum AMP Draw | 24 A | 6 A |
Operating Voltage | 240 V AC only | 120 V AC only |
Operating Frequency | 60 Hz |
Product Dimensions (Front/Side Views)
Diagram Description
Diagrams show front and side views of the dryer with labeled dimensions:
- A: Height (with feet)
- B: Width
- C: Depth
- D: Side Vent Height (feet min)
- E: Side Vent (from back)
Dimension | in (min) | in (max) | mm (min) | mm (max) |
---|---|---|---|---|
A: Height (with feet) | 38¹⁄₁₆ | 39 | 968 | 989 |
B: Width | 27 | - | 686 | - |
C: Depth | 30⁵⁄₁₆ | - | 778 | - |
D: Side Vent Height (feet min) | 3¹⁄₂ | 4³⁄₈ | 89 | 111 |
E: Side Vent (from back) | 10³⁄₁₆ | - | 258 | - |
Product Dimensions (Other Views)
Diagram Description
Diagrams show side and rear views of the dryer with labeled dimensions:
- F: Depth with Door Open
- G: Strain Relief from Side (elec) / Power Cord from Side (Canadian)
- H: Strain Relief Height (elec) / Power Cord Height (Canadian)
- I: Power Cord Length (Canadian) / Power Cord from Side (gas)
- J: Power Cord Height (gas) / Power Cord Length (gas)
- K: Gas Valve Height
- L: Gas Valve from Side
- M: Exhaust Duct Height
- N: Exhaust Duct from Side
Dimension | in (min) | in (max) | mm (min) | mm (max) |
---|---|---|---|---|
F: Depth with Door Open | 54⁵⁄₁₆ | - | 1,378 | - |
G: Strain Relief from Side (elec) | 6³⁄₈ | - | 163 | - |
H: Strain Relief Height (elec) | 29⁷⁄₈ | 30¹¹⁄₁₆ | 759 | 780 |
G: Power Cord from Side (Canadian) | 6³⁄₈ | - | 163 | - |
H: Power Cord Height (Canadian) | 29⁷⁄₈ | 30¹¹⁄₁₆ | 759 | 780 |
I: Power Cord Length (Canadian) | 53³⁄₈ | - | 1,356 | - |
I: Power Cord from Side (gas) | 3¹³⁄₁₆ | - | 96 | - |
J: Power Cord Height (gas) | 31¹³⁄₁₆ | 32¹¹⁄₁₆ | 808 | 829 |
J: Power Cord Length (gas) | 72 | - | 1,828 | - |
K: Gas Valve Height | 5⁵⁄₈ | 6³⁄₈ | 142 | 163 |
L: Gas Valve from Side | 1³⁄₈ | - | 36 | - |
M: Exhaust Duct Height | 3¹⁄₂ | 4³⁄₈ | 90 | 111 |
N: Exhaust Duct from Side | 14¹⁄₈ | - | 358 | - |
Installation Spacing for Recessed Area or Closet
The dimensions shown are for recommended spacing. Additional spacing may be needed for installation, servicing, wall/door/floor moldings, and to reduce noise transfer (1" / 25 mm on all sides recommended).
For closet installation with a door, minimum ventilation openings are required in the top and bottom of the door. Louvered doors with equivalent openings are acceptable. Consider spacing for adjacent appliances.
Diagram Description
Diagram illustrates clearances for recessed or closet installation:
- Maximum depth clearance: 14" (356 mm)
- Top clearance: 18" (460 mm)
- Side clearances: 3" (76 mm)
- Ventilation openings required for closets: 48 sq. in. (310 cm²) at the top and 24 sq. in. (155 cm²) at the bottom.
- Minimum/Recommended spacing: 6" (152 mm) for side vent, 1" (25 mm) for other clearances.