Honeywell BW™ RigRat Portable Multi-Gas Detector
Enhance worker safety with improved convenience and adherence to safety procedures.
Key Features and Benefits
- Extended Operation: Up to 8 weeks of operation on a single charge, offering longer runtime than comparable detectors.
- Versatile Sensing: Up to six sensor slots for interchangeable gas sensors, including electrochemical, PID, infrared, and catalytic bead sensors.
- Efficient Configuration: Programmable inputs and outputs for efficient setup and integration.
- Hazardous Environment Approval: Approved for use in explosive environments, certified for ATEX/IECEx Zone 0 and CSA C1 D1.
- Broad Applications: Suitable for confined spaces, hazardous area classification, routine maintenance, and remote sampling.
- Simple Operation: Single-button operation for ease of use, requiring no specialized knowledge.
- Smart Connectivity: Simple smartphone configuration via a mobile app for alarm setpoints, calibration history, and more.
- Enhanced Protection: Alerts workers to nearby gas leaks, providing broader protection than personal detectors that only monitor breathing zones.
Functionality and Advantages
Wireless Safety Perimeter
Deploy multiple Honeywell BW RigRat gas detectors wirelessly to form a safety perimeter.
Remote Monitoring
Utilize Honeywell's remote monitoring software to view gas readings, locations, and other data from any internet-connected device, enabling rapid, informed decision-making.
Compatibility with Honeywell Touchpoint™ PLUS
Integrate with Honeywell Touchpoint™ Plus controllers to manage data from Honeywell BW RigRat detectors and personal gas detectors.
Additional Honeywell BW RigRat Features
- Field-Replaceable Battery: Power to extend runtime in the field.
- I/O Ports: For additional input functionality and local activation.
- Inert Mode: Prevents alarms when ambient air is normal.
- Large Display: Easy-to-read large display for quick status checks.
- Rugged Design: Robust, water-resistant design (optional protective cage available).
Technical Specifications (General)
Specification | Details |
---|---|
Model Number | BWRR100P / BWRR100D |
Dimensions | 40.0 x 29.0 x 47.0 cm |
Weight | 8 kg |
Gas Sensor Slots | Up to 6 |
Gas Sampling Method | Pumped or Diffused |
Battery | Rechargeable Li-ion battery (3.7V/26.4 Ah) |
Recharge Time | Less than 18 hours (when off) |
Operating Time | Up to 8 weeks (low-power models), varies by model |
Keypad | Single-button operation and programming |
Display | 3.5" 240 x 320 TFT color LCD (with LED backlight) |
Alarms | Red/yellow/green LED alarms, 1m buzzer at 108 dBA, alarm status screen |
Data Logging | Stores full gas sensor and instrument data at 1-minute intervals for at least 4 months |
Wireless | ISM band: Bluetooth Low Energy (BT 4.2/5.0), 2.4 GHz. Mesh module: IEEE 802.15.4 (868 MHz/915 MHz/2.4 GHz). Wi-Fi module: 802.11 b/g/n 2.4 GHz. |
Wireless Module & Range | Bluetooth Low Energy: RMBLEC, up to 5m. Mesh: RM900A or RM2400, up to 300m. Wi-Fi: RMWIFIC, up to 50m. |
Location | GPS receiver module: GPS L1 frequency (1575.42 MHz) (optional) |
IP Rating | IP65 for pumped models, IP67 for diffused models |
Operating Temperature | Pumped models: -20 to +60°C. Diffused models: -40 to +60°C |
Operating Humidity | 5% to 95% RH (non-condensing) |
Safety Certifications | CCSAus Class I Division 1; Group A, B, C, D; T4. IECEx II 1G Ex ia da IIC T4 Ga. For LEL/IR/CO2 sensors: II 2G Ex ia da db IIC T4 Gb, II 1G Ex ia da IIC T4 Ga. |
Wireless Approval | FCC Part 15, IC, RED |
ROHS | RoHS compliant, Directive (EU) 2015/863 |
Sound Level | 70-110 dBA range (response: 100 Hz-8 kHz), 1 dB resolution. A-weighted equivalent sound level over 15 seconds, updated every 5 seconds. |
External Ports |
|
Sensor Specifications
Sensor | Range | Resolution | Temperature Range |
---|---|---|---|
Combustible Gas (IR)* | 0-100% LEL / 0-100% vol. | 1% LEL / 0.1% vol. | -40 to +140° F / -40 to +60° C |
Combustible Gas (LEL) | 0-100% LEL | 1% LEL | -40 to +140° F / -40 to +60° C |
Carbon Dioxide (CO₂) | 0-5% vol. / 100 ppm | 0.01% vol. / 100 ppm | -4 to +131° F / -20 to +50° C |
Carbon Dioxide (CO₂) (External Range) | 0-100% vol. | 0.1% vol. | -4 to +131° F / -20 to +50° C |
Volatile Organic Compounds (VOC) | 0-2000 ppm | 0.1 ppm | -4 to +131° F / -20 to +50° C |
Carbon Monoxide (CO) | 0-500 ppm | 1 ppm | -40 to +140° F / -40 to +60° C |
Carbon Monoxide (CO) (External Range) | 0-2000 ppm | 10 ppm | -4 to +131° F / -20 to +50° C |
Carbon Monoxide (CO) (H₂ Tolerant) | 0-1000 ppm | 5 ppm | -4 to +140° F / -20 to +60° C |
Hydrogen Sulfide (H₂S) | 0-100 ppm | 0.1 ppm | -40 to +140° F / -40 to +60° C |
Hydrogen Sulfide (H₂S) (External Range) | 0-1000 ppm | 1 ppm | -4 to +131° F / -20 to +50° C |
Sulfur Dioxide (SO₂) | 0-20 ppm | 0.1 ppm | -40 to +140° F / -40 to +60° C |
Oxygen (O₂) | 0-30% vol. | 0.1% vol. | -40 to +140° F / -40 to +60° C |
Nitric Oxide (NO) | 0-250 ppm | 0.5 ppm | -4 to +131° F / -20 to +50° C |
Nitrogen Dioxide (NO₂) | 0-20 ppm | 0.1 ppm | -4 to +131° F / -20 to +50° C |
Hydrogen Cyanide (HCN) | 0-50 ppm | 0.5 ppm | -4 to +131° F / -20 to +50° C |
Ammonia (NH₃) | 0-100 ppm | 1 ppm | -4 to +131° F / -20 to +50° C |
Chlorine (Cl₂) | 0-50 ppm | 0.1 ppm | -4 to +131° F / -20 to +50° C |
*Note: Dynament Combustible IR Sensor temperature range is -20 to +50°C.
Optional Accessory: SolarPak BW™ RIGRAT
The Honeywell BW™ RigRat can operate with the SolarPak BW™ RIGRAT. Some gas detector settings do not provide continuous operation and only extend runtime. Refer to the manual for details.
Certifications
US/Canada
Class I, Division 1, Groups A, B, C, D T4
Europe
ATEX II 1 G Ex ia IIC T4 Ga -40°C ≤ Ta ≤ +60°C
IECEx
Ex ia IIC T4 Ga -40°C ≤ Ta ≤ +60°C