Honeywell BW™ RigRat
Transportable Multi-gas Area Monitor
Comply with safety procedures and protect workers with the most user-friendly area monitor of its kind.
The Honeywell BW™ RigRat is an easy-to-use area monitor that provides confidence to workers, alerting them to gas threats in their proximity – indoors and out, in temperatures from -40 to +140°F (-40 to +60°C). The Honeywell BW™ RigRat delivers:
- Up to 8 weeks of runtime on a single charge, offering longer runtime than any area monitor in its class.
- Up to six slots for interchangeable gas sensors, supporting electrochemical, PID, infrared, and catalytic bead sensors (measuring percent LEL and percent by volume).
- Integrated Noise sensor and Metrological data sensors.
- Enhanced configurations with programmable input and output.
- Approval for explosive atmosphere, certified for ATEX/IECEx Zone 0 and CSA C1D1.
- Flexible applications including zone declassification, turnarounds, confined space, routine maintenance, and fence line monitoring. Available with an optional pump for remote sampling.
- One-button operation for grab-and-go use, requiring no expertise.
- Simple setup with a smartphone via an easy mobile app for alarm set points, calibration records, and more.
- Added protection by alerting workers to nearby gas leaks, complementing personal detectors that cover only the breathing zone.
Device Description
The Honeywell BW™ RigRat is depicted as a robust, yellow and black portable gas detection unit. It features a prominent antenna, a clear display screen showing gas readings (e.g., OXY 20.9%), and several indicator lights. The unit is mounted on a yellow, circular base designed for stability.
Features and Benefits
Wireless Safety Perimeter
Position several Honeywell BW™ RigRat monitors to form a wireless safety perimeter.
Remote Monitoring
Utilize Honeywell's remote monitoring software to view gas readings, location, and other data from any internet-connected device for fast, informed decisions. An optional noise sensor or meteorological sensor can be added.
Honeywell TouchPoint™ Plus Compatible
Use with the Honeywell TouchPoint™ Plus controller for visibility of Honeywell BW™ RigRat monitors and workers' personal detectors.
Other Honeywell BW™ RigRat Features
- Line power for extended runtime in the field.
- I/O ports providing additional input capabilities and local executive activation.
- Inert mode that prevents alarm in normal ambient air.
- Large, easy-to-read display.
- Rugged, weatherproof design, with an optional protective cage.
Technical Specifications
Instrument Specifications (Typical)
Specification | Value |
---|---|
Model Number | BWRR100P / BWRR100D |
Size | 15.8 x 11.4 x 18.5 in. / 40.0 x 29.0 x 47.0 cm |
Weight | 17.6 lb / 8 kg |
Gas Sensor Slots | Up to 6 |
Gas Sampling Method | Pumped or diffusion |
Battery | Rechargeable Li-ion battery (3.7V / 26.4 Ah) |
Charging Time | Less than 18 hours (instrument powered off) |
Running Time | 8 weeks (low-power model); other models vary by configuration |
Keypads | One-button operation and programming |
Display | 3.5" 240 x 320 TFT color LCD with white LED backlight |
Alarm | Red/yellow/green LED alarm; buzzer alarm 108 dBA @ 1 m; on-screen indication of alarm conditions |
Datalogging | Complete gas sensors and instrument information for at least 4 months at one-minute intervals |
Wireless | ISM license-free band: Bluetooth Low Energy (BT 4.2 / 5.0), 2.4 GHz (default); Mesh Module: IEEE 802.15.4 868/915 MHz/2.4 GHz (optional); Wi-Fi Module: 802.11 b/g/n 2.4 GHz (optional) |
Radio Module & Range | Bluetooth Low Energy: up to 16.4 ft. / 5 m; Mesh: up to 984 ft. / 300 m (868-900 MHz) or 492 ft. / 150 m (2.4 GHz); Wi-Fi: up to 164 ft. / 50 m |
Outdoor Location | GPS receiver module: GPS L1 frequency (1575.42 MHz) (optional); Only with IEEE 802.15.4 868/915 MHz modem and WIFI |
IP Rating | IP65 for pumped models; IP67 for diffusion models |
Temperature | -4 to +140°F (-20 to +60°C) for pumped models; -40 to +140°F (-40 to +60°C) for diffusion models |
Humidity | 5 - 95% RH (non-condensing) |
Safety Certifications | cETLus Class I Division 1; Group A, B, C, D; T4; IEC EX/ATEX II 1G Ex ia da IIC T4 Ga; For LEL/IR/CO2 sensor: II 2G Ex ia da db IIC T4 Gb; 1G Ex ia da IIC T4 Ga |
Wireless Approvals | FCC Part 15, IC, RE-D |
ROHS (Pending) | RoHS Complaint, Directive (EU) 2015/863 |
Noise Sensor | 60-125 dBA range; (respond: 100 Hz to 8 kHz), 1 dB resolution; A-weighted 15 second equivalent level; updated every 5 seconds |
External Ports | Safe Area Charge Port (AC CHG SAFE AREA): Battery charger input 6 VDC 3 A typical; connect to AC/DC adaptor. Field Charge (IS CHG HAZARDOUS): Intrinsically safe line power supply input or SolarPak to extend instrument runtime (low-power model only). RAEMet Port (Serial): Port to RAEMet wind sensor (optional). Analog/Switch Input Port (4-20 mA IN): 4-20 mA signal input, X1 channel/switch on/off signal input, X1 channel (optional). ON/OFF Switch Output (SWITCH): Max 20 V / 120 mA, SPDT Normal Open, X3 channels for external ports (optional). Refer to User Guide for complete details. |
Sensor Specifications
Sensor | Range | Resolution | Temperature Range |
---|---|---|---|
COMBUSTIBLE GASES (IR)* | 0-100% LEL / 0-100% vol. | 1% LEL / 0.1% vol. | -40 to +140°F / -40 to +60° C |
COMBUSTIBLE GASES (LEL) | 0-100% LEL | 1% LEL | -40 to +140°F / -40 to +60° C |
CARBON DIOXIDE (CO₂) | 0-5% vol. / 100 ppm | 0.01% vol. / 100 ppm | -4 to +131°F / -20 to +50° C |
CARBON DIOXIDE (CO₂) (EXT. RANGE) | 0-100% vol. | 0.1% vol. | -4 to +131°F / -20 to +50° C |
VOLATILE ORGANIC COMPOUNDS (VOC) | 0-2000 ppm | 0.1 ppm | -4 to +131°F / -20 to +50° C |
CARBON MONOXIDE (CO) | 0-500 ppm | 1 ppm | -40 to +140°F / -40 to +60° C |
CARBON MONOXIDE (CO) (EXT. RANGE) | 0-2000 ppm | 10 ppm | -4 to +131°F / -20 to +50° C |
CARBON MONOXIDE (CO) (H₂ RESISTANT) | 0-1000 ppm | 5 ppm | -4 to +131°F / -20 to +50° C |
HYDROGEN SUFLIDE (H₂S) | 0-100 ppm | 0.1 ppm | -40 to +140°F / -40 to +60° C |
HYDROGEN SUFLIDE (H₂S) (EXT. RANGE) | 0-1000 ppm | 1 ppm | -4 to +131°F / -20 to +50° C |
SULFUR DIOXIDE (SO₂) | 0-20 ppm | 0.1 ppm | -4 to +140°F / -20 to +60° C |
OXYGEN (O₂) | 0-30% vol. | 0.1% vol. | -40 to +140°F / -40 to +60° C |
NITRIC OXIDE (NO) | 0-250 ppm | 0.5 ppm | -4 to +131°F / -20 to +50° C |
NITROGEN DIOXIDE (NO₂) | 0-20 ppm | 0.1 ppm | -40 to +140°F / -40 to +60° C |
HYDROGEN CYANIDE (HCN) | 0-50 ppm | 0.5 ppm | -4 to +131°F / -20 to +50° C |
AMMONIA (NH₃) | 0-100 ppm | 1 ppm | -4 to +131°F / -20 to +50° C |
CHLORINE (CL₂) | 0-50 ppm | 0.1 ppm | -4 to +131°F / -20 to +50° C |
*Note: Temperature range for the Dynament Combustible IR sensor is -4 to +131°F (-20 to +50°C).
Optional Features and Certifications
SolarPak BW™ RigRat (Optional)
The Honeywell BW™ RigRat can be powered by the SolarPak BW™ RigRat. Certain monitor configurations may not provide continuous operation but offer a runtime extension. Please refer to the manual for details.
Certification Markings
USA and Canada
Class I, Division 1, Groups A, B, C, D T4
Europe
ATEX II 1 G Ex ia IIC T4 Ga -40°C ≤ Ta ≤ +60°C
IECEx
Ex ia IIC T4 Ga -40°C ≤ Ta ≤ +60°C
For More Information
Visit: safety.honeywell.com
Note: Due to ongoing research and product improvement, specifications are subject to change without notice.