Honeywell BW™ RigRat
Transportable Multi-gas Area Monitor
Comply with safety procedures and protect workers with the most user-friendly area monitor of its kind.
The Honeywell BW™ RigRat is easy to use, allowing workers to operate it with confidence. It alerts them to gas threats in their proximity, indoors and out, in temperatures from -40 to +140°F (-40 to +60°C). The Honeywell BW™ RigRat delivers:
- Up to 8 weeks of runtime on a single charge, offering longer runtime than any area monitor in its class.
- Up to six slots for interchangeable gas sensors, supporting electrochemical, PID, infrared, and catalytic bead sensors (measuring percent LEL and percent by volume).
- Integrated Noise sensor and Metrological data sensors.
- Enhanced configurations with programmable input and output.
- Approval for explosive atmosphere, certified for ATEX/IECEx Zone 0 and CSA C1D1.
- Flexible applications including zone declassification, turnarounds, confined space, routine maintenance, fence line, and more. Available with a pump for remote sampling.
- One-button operation for grab-and-go use with no expertise required.
- Simple setup with a smartphone via an easy mobile app for alarm set points, calibration records, and more.
- Added protection by alerting workers to nearby gas leaks, whereas personal detectors cover only the breathing zone.
[Image: A yellow and black Honeywell BW™ RigRat portable multi-gas area monitor with an antenna, sitting on a yellow base. It features a display screen and various sensors.]
Features and Benefits
? Wireless Safety Perimeter
Position several Honeywell BW™ RigRat monitors to form a wireless safety perimeter.
?️ Remote Monitoring
Use with Honeywell's remote monitoring software to view gas readings, location, and other data from any device with an internet connection for fast, informed decisions. An optional noise sensor or meteorological sensor can be added.
? Honeywell Touchpoint™ Plus Compatible
Use with the Honeywell Touchpoint™ Plus controller for visibility on Honeywell BW™ RigRat monitors and workers' personal detectors.
Other Honeywell BW™ RigRat Features
- Line power for extended runtime in the field.
- I/O ports providing additional input capabilities and local executive activation.
- Inert mode that prevents alarm in normal ambient air.
- Large, easy-to-read display.
- Rugged, weatherproof design, with an optional protective cage.
Technical Specifications
Instrument Specifications (Typical)
Model Number | BWRR100P/BWRR100D |
---|---|
Size | 15.8 x 11.4 x 18.5 in. / 40.0 x 29.0 x 47.0 cm |
Weight | 17.6 lb / 8 kg |
Gas Sensor Slots | Up to 6 |
Gas Sampling Method | Pumped or diffusion |
Battery | Rechargeable Li-ion battery (3.7V / 26.4 Ah) |
Charging Time | Less than 18 hours when instrument is powered off |
Running Time | 8 weeks for low-power model; other models vary by configuration |
Keypads | One-button operation and programming |
Display | 3.5" 240 x 320 TFT color LCD with white LED backlight |
Alarm | Red/yellow/green LED alarm; buzzer alarm 108 dBA @ 1 m; on-screen indication of alarm conditions |
Datalogging | Complete gas sensors and instrument information for at least 4 months at one-minute intervals |
Wireless | ISM license-free band: Bluetooth Low Energy Module (BT 4.2 / 5.0), 2.4 GHz, in default; Mesh Module: IEEE 802.15.4 868 MHz/915MHz/2.4 GHz (optional); OR Wi-Fi Module: 802.11 b/g/n 2.4 GHz (optional) |
Radio Module & Range | Bluetooth Low Energy: RMBLEC, up to 16.4 ft. / 5 m; Mesh: RM900A, 984 ft. / 300 m (868-900 MHz) or RM2400, 492 ft. / 150 m (2.4 GHz); Wi-Fi: RMWIFIC, up to 164 ft. / 50 m; GPS receiver module: GPS L1 frequency (1575.42 MHz) (optional); Only with IEEE 802.15.4 868 MHz / 915MHz modem and WIFI |
Outdoor Location | IP65 for pumped models; IP67 for diffusion models |
Temperature | -4 to +140°F (-20 to +60°C) for pumped models; -40 to +140°F (-40 to +60°C) for diffusion models |
Humidity | 5 - 95% RH (non-condensing) |
Safety Certifications | cETLus Class I Division 1; Group A, B, C, D; T4; IEC EX/ATEX II 1G Ex ia da IIC T4 Ga. For LEL/IR/CO2 sensor installed: II 2G Ex ia da db IIC T4 Gb. 1G Ex ia da IIC T4 Ga. |
Wireless Approvals | FCC Part 15, IC, RE-D |
RoHS (Pending) | RoHS Complaint, Directive (EU) 2015/863 |
Noise Sensor | 60-125 dBA range; (respond: 100 Hz to 8 kHz), 1 dB resolution; A-weighted 15 second equivalent level; updated every 5 seconds |
External Ports |
|
Sensor Specifications
Sensor | Range | Resolution | Temperature Range |
---|---|---|---|
Combustible Gases (IR)* | 0-100% LEL / 0-100% vol. | 1% LEL / 0.1% vol. | -40 to +140°F / -40 to +60° C |
Combustible Gases (LEL) | 0-100% LEL | 1% LEL | -40 to +140°F / -40 to +60° C |
Carbon Dioxide (CO₂) | 0-5% vol. / 100 ppm | 0.01% vol. / 100 ppm | -4 to +131°F / -20 to +50° C |
Carbon Dioxide (CO₂) (Ext. Range) | 0-100% vol. | 0.1% vol. | -4 to +131°F / -20 to +50° C |
Volatile Organic Compounds (VOC) | 0-2000 ppm | 0.1 ppm | -4 to +131°F / -20 to +50° C |
Carbon Monoxide (CO) | 0-500 ppm | 1 ppm | -40 to +140°F / -40 to +60° C |
Carbon Monoxide (CO) (Ext. Range) | 0-2000 ppm | 10 ppm | -4 to +131°F / -20 to +50° C |
Carbon Monoxide (CO) (H₂ Resistant) | 0-1000 ppm | 5 ppm | -4 to +131°F / -20 to +50° C |
Hydrogen Sulfide (H₂S) | 0-100 ppm | 0.1 ppm | -40 to +140°F / -40 to +60° C |
Hydrogen Sulfide (H₂S) (Ext. Range) | 0-1000 ppm | 1 ppm | -4 to +131°F / -20 to +50° C |
Sulfur Dioxide (SO₂) | 0-20 ppm | 0.1 ppm | -4 to +140°F / -20 to +60° C |
Oxygen (O₂) | 0-30% vol. | 0.1% vol. | -40 to +140°F / -40 to +60° C |
Nitric Oxide (NO) | 0-250 ppm | 0.5 ppm | -4 to +131°F / -20 to +50° C |
Nitrogen Dioxide (NO₂) | 0-20 ppm | 0.1 ppm | -40 to +140°F / -40 to +60° C |
Hydrogen Cyanide (HCN) | 0-50 ppm | 0.5 ppm | -4 to +131°F / -20 to +50° C |
Ammonia (NH₃) | 0-100 ppm | 1 ppm | -4 to +131°F / -20 to +50° C |
Chlorine (Cl₂) | 0-50 ppm | 0.1 ppm | -4 to +131°F / -20 to +50° C |
*Note: Temperature range for the Dynament Combustible IR sensor is -4 to +131°F (-20 to +50°C).
Optional SolarPak
The Honeywell BW™ RigRat can be powered by the SolarPak BW™ RigRat. Certain monitor configurations will not provide continuous operation but only a runtime extension. Please refer to the manual for details.
Certification Markings
USA and Canada: Class I, Division 1, Groups A, B, C, D T4
Europe: ATEX II 1 G Ex ia IIC T4 Ga -40°C ≤ Ta ≤ +60°C
IECEx: Ex ia IIC T4 Ga -40°C ≤ Ta ≤ +60°C