Nordlux IP S13 Outdoor Lighting Fixture
Model Numbers: IP S13 | 40, IP S13 | 60
Important Safety Information
- Electrical Safety: Always shut off power to the circuit before starting installation work. In some countries, electrical installation work may only be carried out by an authorized electrical contractor. Contact your local electricity authority for advice.
- Installation Zones: A diagram illustrates safety zones for electrical installations, particularly relevant for areas near water. Zone 0 is inside a bathtub or shower tray. Zone 1 extends up to 2.25 meters above the bathtub or shower tray. Zone 2 extends 60 cm horizontally from Zone 1 and up to 2.25 meters in height.
Product Ratings
IPX4 Rating: This fixture is protected against splashing water from any angle (360°), ensuring its function and safety.
Electrical Protection: Class II. The fixture is double-insulated and does not require connection to the earth wire (yellow/green).
Mounting Instructions
Follow these steps for mounting the Nordlux IP S13 fixture:
- Step 1: Preparation Identify all components: main lamp body, mounting plate, screws, wall plugs, and wire connector. Ensure power is OFF.
- Step 2: Wall Mounting Attach the mounting plate securely to the wall using the provided screws and wall plugs. Ensure wires from the wall are accessible.
- Step 3: Wiring Connection Connect the wires from the wall to the lamp's internal terminal block using the provided wire connector.
- Step 4: Final Assembly Attach the main lamp body to the mounted plate and secure it.
Note: This lamp is designed for direct and fixed mounting to the mains power supply.
Transformer Information
If the supplied safety transformer is damaged, it must be replaced with an identical transformer that has the same specifications.
General Notes
Keep Instructions: Please retain this mounting guide for future reference. Do not discard.