microlife
SureFit Blood Pressure Cuff
Model WRSC
Size: 8.7" - 16.5" (22-42 cm)
User Manual
1. Introduction
Thank you for purchasing a Microlife SureFit cuff. This cuff is suitable for arm circumferences of 8.7" to 16.5" (22-42 cm) and is designed to be easily adaptable to most Microlife blood pressure monitors.
2. Components of Your Blood Pressure Cuff
2.1. Cuff Assembly
The cuff assembly consists of the cuff itself and an attached hose. The cuff is a fabric sleeve that wraps around the arm, containing an internal inflatable bladder. The hose connects the cuff to the blood pressure monitor.
Diagram Description: An illustration shows the cuff, a cylindrical fabric tube, with a flexible hose extending from one side.
2.2. Cuff Assembly & Connector Types
The cuff comes with a connector at the end of the hose, which plugs into the blood pressure monitor. This package includes multiple connector types to ensure compatibility with various Microlife monitor models.
Diagram Description: Illustrations show two cuff assemblies with different connectors attached to the hose. The connector types are labeled:
- Advanced connector-1
- Advanced connector-2
- Standard connector
Important Product and Safety Information
Follow Instructions for Use. This document provides important product operation and safety information regarding this blood pressure monitor replacement cuff. Please read this document thoroughly before using the component and keep for future reference.
This blood pressure cuff is a replacement for the cuff included with your upper arm, Microlife produced, automatic blood pressure monitor. This component is only for use with Microlife produced automatic (oscillometric) blood pressure monitors, by adults, at home or in the doctor's office.
This replacement blood pressure monitor cuff IS intended to be used:
- As a replacement for your Microlife manufactured, automatic, blood pressure monitor's cuff.
- Within a home healthcare environment; where the person being measured may be the user/operator.
- With the cuff located upon the user's upper arm; 1/2 inch above the elbow over the artery as indicated on the cuff.
This replacement blood pressure monitor cuff IS NOT intended for use with:
- Blood pressure monitors produced by other manufacturers than Microlife.
- Any body location other than that of the upper arm.
- Users under the age of 12.
⚠️ WARNING – Potentially hazardous situation that if not avoided may result in serious injury or death.
- Only use this component as a replacement to the cuff included in your current Microlife produced, automatic, upper arm, blood pressure monitor. For blood pressure measurements, continue to follow all instructions that accompanied your original Microlife produced blood pressure monitor.
- Though not for use with children under 12, ensure that any children around this component are supervised; some parts are small enough to be swallowed and any present tubes or cables may provide a risk of strangulation.
- Ensure the cuff tubing is not kinked during use, as harmful injury may occur due to the effect of blood flow interference caused by high pressure in the cuff not releasing.
DO NOT:
- ✕ Use this component if you think it is damaged or anything appears unusual.
- ✕ Open/modify this component; inaccuracy and/or harmful injury may result.
- ✕ Conduct many frequent measurements as this may result in harmful injury due to blood flow interference.
- ✕ Place the cuff over a wound as this may cause further injury.
- ✕ Place and pressurize the cuff over/near any present intravascular access or therapy, or arteriovenous shunt, as this may cause blood flow interference and result in harmful injury.
- ✕ Place and pressurize the cuff over a limb near the side of a mastectomy as this may cause harmful injury.
- ✕ Use this component on a limb simultaneously with other medical equipment on the same limb due to possible interference with such medical equipment.
- ✕ Maintain pressure in the cuff applied to the limb for a prolonged amount of time. Ensure that circulation in the limb is not impaired by checking circulation if prolonged/repeated exposure to pressure occurs.
⚠️ CAUTION – Potentially hazardous situation that if not avoided may result in minor/moderate injury, property damage, and/or damage to the component.
- To avoid inaccurate measurements and to lessen any discomfort from cuff pressure, ensure the cuff is placed correctly on the limb and fits correctly when snug (not tight), as indicated by markings on the cuff.
DO NOT:
- ✕ Use this component outside of its specified operation temperature and humidity rating, or if stored outside of its specified storage temperature and humidity rating. Avoid storage in direct sunlight.
STANDARDS:
- In addition to the standards stated in the Instruction Manual: Clinical Testing per standard ISO 81060-2:2013 was conducted on blood pressure component using the same measurement technology.
EXPECTED LIFE:
- Cuff: 2 Years or 10,000 uses (whichever comes first)
3. Select Your Connector
IMPORTANT: This replacement package includes multiple connector types. It is critical that the correct connector be used for proper function and accurate readings.
- Examine your old Microlife blood pressure cuff and its connector. Identify the shape and color of the connector that plugs into your monitor.
- From the provided replacement package, select a new connector that matches the color and shape of your old one.
- Attach the selected matching cuff connector securely to the end of the new cuff hose.
- Connect the new cuff assembly (cuff, hose, and connector) to your Microlife automatic blood pressure monitor. Ensure the connection fits snugly and is not loose.
- Once the cuff is properly connected to the monitor, it is ready for use.
Diagram Description: Illustrations show how to connect the cuff hose to either an "Advanced connector" or a "Standard connector".
Questions? Please contact customer service: 1-800-568-4147.
4. Applying the Cuff
- Ensure clothing does not interfere with the cuff. Remove any tight or bulky items that might restrict the arm.
- Slide the cuff onto the arm, positioning it as illustrated. The hose should be closer to your lower arm. The lower edge of the cuff should be approximately 1/2 inch (1 to 2 cm) above the elbow, with the hose positioned towards the inner side of the arm.
- IMPORTANT: The Artery Mark Indicator on the cuff must lie directly over the brachial artery. The brachial artery is located on the inside of the upper arm, generally under the front of the armpit.
- TIP: Align the Artery Mark to point towards your pinky finger, not the center of your arm.
- Tighten the cuff by pulling the free end and securing it with the hook & loop material.
- Ensure the cuff is tightened correctly. It should fit the arm snugly, allowing you to slide two fingers between the cuff and your arm. It should not be too tight or too loose.
- Once the cuff is in position and adjusted, check that the "Sizing Seam" marking falls within the "Size Range" marking on the cuff. If it does not, the cuff may not be the correct size for your arm.
Caution: Incorrect cuff sizing or application can lead to inaccurate blood pressure measurements. Systolic readings may swing by up to 10 mmHg, and a cuff that is too loose or too tight will result in an inaccurate reading.
For assistance in determining or obtaining the correct cuff size, please contact customer service or visit the Microlife website.
Diagram Description: Illustrations show:
- The arm circumference range (8.7" - 16.5").
- Cuff placement showing the 1/2" (1-2 cm) gap above the elbow and the hose position towards the inner arm.
- The Artery Mark aligned over the brachial artery.
- The cuff being tightened with hook & loop.
- The two-finger test for snugness.
Comment: If it is not possible to fit the cuff to your left arm, it can also be placed on your right arm. Ensure all measurements are taken on the same arm.
Using the cuff: Follow all instructions included with your original Microlife blood pressure monitor when taking a blood pressure measurement.
Instruction manuals for most monitors produced by Microlife are available on our website: www.microlifeusa.com
Diagram Description: An illustration shows the cuff correctly applied to the right arm.
5. Care and Maintenance
- The cuff contains a sensitive airtight bladder. Handle the cuff carefully to avoid stress from twisting or folding. Do not pull on the hose. Keep the cuff and hose away from sharp objects.
- Clean the cuff exterior with a soft, dry cloth. Spots can be removed carefully with a damp cloth and mild soapsuds. Do not submerge the cuff in water, place it in a dishwasher, or use chemical cleaning agents or solvents.
- Do not use the device if you believe it is damaged or if anything appears unusual.
6. Limited Warranty
Your Microlife SureFit cuff is warranted by Microlife USA Inc. for one year from the date of purchase against manufacturer defects for the original purchaser only.
This warranty does not cover consequential or incidental damages, or damage caused by improper handling, accidents, professional use, failure to follow operating instructions, or alterations made by third parties.
Some states may not allow the exclusion or limitation of incidental or consequential damages, so these limitations may not apply to you.
Microlife USA Inc. will investigate your concern. If a cuff is determined to be out of specification under this warranty, it will be replaced and shipped at no cost. If it is determined to be within specification, it will be returned with a report of findings, at no cost.
For any warranty concerns, please use the customer service contact information provided below. Contact Microlife USA Inc. before returning any product to help identify the issue and process your claim more quickly.
This warranty grants specific legal rights, and you may also have other rights that vary by state.
7. Technical Specifications
Specification | Details |
---|---|
Cuff Type | SureFit cuff for arms, circumference 8.7" - 16.5" (22 - 42 cm) |
Weight | 160 g |
Storage Temperature | -20 to +55°C (-4° to +131°F) |
Operation Temperature | 10 to 40°C (50° to 104°F) |
Operation/Storage Humidity | 15 to 90% relative humidity maximum |
Expected Service Life | 2 years or 10,000 uses (whichever comes first) |
Technical alterations reserved. Made in China.