Set Up Precautions

  1. Set up and use only on a flat, level, dry, well-ventilated surface.
  2. All connections and conduits from the Generators to the load must only be installed by trained and licensed electricians, and in compliance with all relevant local, state, and federal electrical codes and standards, and other regulations where applicable.
  3. Wear safety goggles during set up.
  4. Inspect thoroughly before each use. Do not use if damaged.
  5. Do not plug more than the specified number of watts into this cord.
  6. Do not run Parallel Kit through doorways, holes in ceilings, walls, or floors.
  7. Use two of the same model generator. Do not use two different generator models.
  8. Turn generators off before connecting the Parallel Kit.
  9. Fully insert cable plugs into outlets.
  10. Do not remove, bend, or modify any metal prongs or pins of the Parallel Kit.
  11. Do not use excessive force to make connections.
  12. Keep away from water.
  13. Keep Parallel Kit dry and away from wet ground and mud.
  14. Do not drive, drag, or place objects over Parallel Kit Cords.
  15. Do not walk on Parallel Kit Cords.

Operating Precautions

WARNING! TO PREVENT SERIOUS INJURY, DEATH, AND GENERATOR AND/OR EQUIPMENT DAMAGE FROM ELECTRIC SHOCK AND FIRE:

  1. Never use generators indoors, including in garages, basements, crawl spaces, and sheds. Opening doors and windows or using fans will NOT prevent carbon monoxide build-up in the home.
  2. When using generators, keep them outdoors and far away from open doors, windows, and vents to avoid toxic levels of carbon monoxide from building up indoors.
  3. If you start to feel sick, dizzy, or weak while using generators, get to fresh air right away. The carbon monoxide from generators can quickly lead to full incapacitation and death.
  4. Keep children and pets away from the Parallel Kit, especially while it is operating.
  5. Do not exceed the maximum power rating of the generators. Make sure that the total electrical rating of all the tools or appliances plugged into the generators at the same time does not exceed that of the generator. Check that the startup surge will not be beyond the limit of the generators.
  6. Avoid substantially overloading which will trip the circuit breaker. Slightly overloading the generators may not trip the circuit breaker, but will lead to premature generator failure.
  7. Do not attempt to connect or disconnect load connections while standing in water, or on wet or soggy ground.
  8. Do not touch electrically energized parts of the generators and interconnecting cables or conductors with any part of the body, or with any non-insulated conductive object.
  9. Insulate all connections and disconnected wires.
  10. Guard against electric shock. Prevent body contact with grounded surfaces such as pipes, radiators, ranges, and refrigerators.
  11. Only connect two identical Inverter Generators together using the Parallel Kit.
  12. Connect Parallel Kit only to terminals marked "Parallel Outlets" on the front of the generator.
  13. Do not remove or connect Parallel Kit while generators are running.
  14. Do not attach a Parallel Kit to only one generator.
  15. Do not attach a heavy load to any other outlet on a Generator that has a Parallel Kit attached.
  16. Wear safety glasses during use.
  17. People with pacemakers should consult their physician(s) before use. Electromagnetic fields in close proximity to a heart pacemaker could cause pacemaker interference or pacemaker failure. Caution is necessary when near the engine's magneto or recoil starter.
  18. Accessories that may be suitable for one piece of equipment may become hazardous when used on another piece of equipment.
  19. Stay alert, watch what you are doing, and use common sense when operating this parallel kit. Do not use while tired or under the influence of drugs, alcohol, or medication.
  20. Dress properly. Do not wear loose clothing or jewelry. Keep hair, clothing, and gloves away from moving parts. Loose clothes, jewelry, or long hair can be caught in moving parts.
  21. Use the equipment, accessories, etc., in accordance with these instructions and in the manner intended for the particular type of equipment, taking into account the working conditions and the work to be performed. Use of the equipment for operations different from those intended could result in a hazardous situation.
  22. WARNING: This product contains, or when used, produces a chemical known to the State of California to cause cancer and birth defects or other reproductive harm. (California Health & Safety Code § 25249.5, et seq.)
  23. Before use, check for misalignment or binding of moving parts, breakage of parts, and any other condition that may affect the equipment's operation. If damaged, have the equipment serviced before using. Many accidents are caused by poorly maintained equipment.
  24. Use the correct equipment for the application. Do not modify the equipment and do not use the equipment for a purpose for which it is not intended.

Service Precautions

  1. Before service, maintenance, or cleaning, unplug the Parallel Kit from both generators.
  2. Keep all electrical equipment clean and dry. Replace any wiring where the insulation is cracked, cut, abraded, or otherwise degraded. Replace terminals that are worn, discolored, or corroded. Keep terminals clean and tight.
  3. Do not alter or adjust any part of the equipment or its engine that is sealed by the manufacturer or distributor. Only a qualified service technician may adjust parts that may increase or decrease governed engine speed.
  4. Wear safety goggles during service.
  5. Maintain labels and nameplates on the equipment. These carry important information.
  6. Have the equipment serviced by a qualified repair person using only identical replacement parts. This will ensure that the safety of the equipment is maintained. Do not attempt any service or maintenance procedures not explained in this manual or any procedures that you are uncertain about your ability to perform safely or correctly.
  7. Store equipment out of the reach of children.

OPERATION

Components

The parallel kit includes a parallel device line, handle, panel (left and right sides), and parallel input interface with connectors.

Panel Description

Setup and Connection Procedure

Read the ENTIRE IMPORTANT SAFETY INFORMATION section at the beginning of this manual including all text under subheadings therein before set up or use of this product.

  1. Inspect the Parallel Kit and generators for damaged, loose, and missing parts before set up and starting. If any problems are found, do not use equipment until fixed properly.
  2. Add fuel and oil to the generators according to the instructions in the generator manual.
  3. Set up the Parallel Kit either on the ground or clipped to one of the two generators.
  4. Connection cable:
    1. Connect the Connectors (red) to the parallel outlets (red) on both generators and Parallel Kit.
    2. Connect the Connectors (black) to the parallel outlets (black) on both generators and Parallel Kit.
    3. Connect the ground connector (ring) to the ground terminal of the generator and the parallel component, and connect the ground bolt on the parallel component to the ground screw using a ground cable. Tighten the ground screw.
  5. Turn on one generator, then the second. Check that the Output lights of both generators are green.
  6. Turn LOW IDLE to “ON”.
  7. Attach load to Parallel Kit.

Note: If one generator shuts off during use, disconnect load until it can be restarted to avoid generator damage.

Do not overload the generators. Substantial overloading will shut off the AC output and may shorten the service life of the generators.

Note: The voltage of the parallel device is 120V, and the output current is 80A (a 50A socket and a 30A socket). Three generators can be connected in parallel at the same time, and the total power in parallel should not exceed 9600 peak watts.

TROUBLESHOOTING

WARNING! TO PREVENT SERIOUS INJURY FROM EQUIPMENT FAILURE: Do not use damaged equipment. If abnormal noise, vibration, or excess smoking occurs, have the problem corrected before further use. Procedures not specifically explained in this manual must be performed only by a qualified technician.

  1. BEFORE EACH USE, inspect the general condition of the charger. Check for:
    • loose hardware,
    • cracked or broken parts,
    • damaged electrical wiring or cable insulation, and
    • any other condition that may affect its safe operation.
  2. After Use, wipe external surfaces of the tool with clean cloth.
Problem Possible Causes Probable Solutions
Parallel Kit doesn't have power. 1. Device not plugged in properly.
2. Circuit Breaker tripped.
3. Parallel Kit needs service.
1. Turn off generator and check outlet connections for correct positioning. Restart generator.
2. Turn off and unplug Parallel Kit, reset Circuit Breaker, plug in Parallel Kit and turn on.
3. Have Parallel Kit repaired.
Overload indicator flashes. Rated load capacity exceeded. Lower the number of items plugged into the generator to stay within the rated capacity.

Follow all safety precautions whenever diagnosing or servicing the Parallel Kit.

Models: 50-Amp RV Ready, Inverter Generator Parallel Kit, 50-Amp RV Ready Inverter Generator Parallel Kit, RV Ready Inverter Generator Parallel Kit, Generator Parallel Kit, Parallel Kit

File Info : application/pdf, 8 Pages, 905.71KB

PDF preview unavailable. Download the PDF instead.

1559059991370014721 Corel PDF Engine Version 18.1.0.661 CorelDRAW X8

Related Documents

Preview GENMAX GM9000PK Inverter Parallel Kit Operation Guide
Comprehensive guide for operating the GENMAX GM9000PK inverter parallel kit. Learn safe installation, connection, and operation procedures for dual generator power, including important warnings and notices.
Preview GENMAX GM12000ED Inverter Generator User's Manual
Comprehensive user's manual for the GENMAX GM12000ED Inverter Generator, covering safety instructions, operation, maintenance, troubleshooting, and technical specifications for this dual-fuel portable generator.
Preview GENMAX GM9000iED Dual Fuel Inverter Generator User Manual
Comprehensive user manual for the GENMAX GM9000iED dual fuel inverter generator. This guide covers essential safety precautions, detailed operating instructions for both gasoline and propane, maintenance schedules, and troubleshooting tips for the 7600W/9000W remote start generator.
Preview Genmax GM5500XID Inverter Generator User's Manual
Comprehensive user's manual for the Genmax GM5500XID portable dual fuel inverter generator, covering safety, operation, maintenance, troubleshooting, and technical specifications.
Preview Genmax GM5500i & GM6000iED Inverter Generator User's Manual
Comprehensive user's manual for Genmax GM5500i and GM6000iED portable inverter generators, covering safety, operation, maintenance, troubleshooting, and technical specifications. Learn about component descriptions, control functions, starting and shutdown procedures, environmental considerations, wiring, grounding, battery charging, service schedules, storage, and technical data.
Preview GENMAX GM7500iAED Inverter Generator User Manual: Safety, Operation, and Maintenance
Official user manual for the GENMAX GM7500iAED Portable Dual Fuel Inverter Generator. Covers setup, operation, safety precautions, maintenance schedule, troubleshooting, technical specifications, and choosing the right generator. Includes details on gasoline and LPG use.
Preview Genmax GM11000iET Tri-Fuel Inverter Generator User's Manual
Comprehensive user's manual for the Genmax GM11000iET Tri-Fuel Inverter Generator, covering safety instructions, operation, maintenance, troubleshooting, and technical specifications.
Preview Genmax GM5500i Portable Inverter Generator User's Manual
This user manual provides comprehensive instructions for the Genmax GM5500i portable inverter generator, covering safety warnings, operation, maintenance, troubleshooting, and technical specifications. Learn how to safely start, use, and maintain your generator for optimal performance.