Introduction
Thank you for purchasing the SALUS RX10RF system receiver. This unit is designed to work with the iT600 range of Zigbee network products. The RX10RF can be configured as a remote boiler switch or a simple single channel output to control a thermal actuator or zone valve. These configurations can be used together in one system.
These instructions are applicable to the SALUS model stated on the front cover of this manual only.
Box Contents
- SALUS RX10RF Wireless Receiver Unit x 1
- Installer / User Manual x 1
- Screws x 2
- Wall Plugs x 2
For PDF Installation guide please go to www.salus-controls.com.
Safety and Compliance
Safety Warnings
⚠️ This product must be fitted by a competent person, and installation must comply with the guidance, standards and regulations applicable to the city, country or state where the product is installed. Failure to comply with the requirements of the relevant guidance, standards and regulations could lead to injury, death or prosecution.
Sources of Danger
The RX10RF must be disconnected from mains supply before removing the cover.
Emergency
Switch off the voltage to the individual thermostat wiring centre or complete system.
General Warning
⚠️ Always isolate the AC Mains supply before installing or working on any components that require 230 VAC 50Hz supply.
Product Compliance
This product is CE compliant and meets the following EC Directives: 2014/30/EU; 2014/35/EU; 2014/53/EU and 2011/65/EU.
Installation Guide
Electrical Connection
Terminal | Function |
---|---|
COM | Common Contact (volt free input) |
NO | Normally Open Contact (volt free output) |
L | Earth Parking |
N | Incoming Mains - Live |
Incoming Mains - Neutral |
The RX10RF Receiver should be mounted in a suitable location that is both accessible for the connection of mains and control wiring, and allows good reception of the RF signal. The Receiver needs a 230V AC mains supply to operate, and this should be fused appropriately (16A max.).
The Receiver should be mounted in a location where it will not come into contact with water, moisture or condensation. There are few electrical connections required to the RX10RF, and these connections should be made to the terminal block inside the Receiver. No Earth connection is required for the correct and safe operation of the RX10RF, but a parking terminal is provided to connect an Earth wire if one is present.
Installation Steps
Step 1: Loosen Screws
Loosen the screws at the bottom of the receiver unit.
Step 2: Unclip Front
Unclip the front of the unit.
Step 3: Mount Backplate
Fit the back of the receiver unit to the wall using the fittings supplied.
Step 4: Wire Receiver
Wire up the receiver using one of the schematics. The schematics show configurations for RX1 (Boiler Receiver) and RX2 (Single Room Receiver).
Step 5: Re-attach Front
Clip the front of the unit back on by aligning the fittings and pushing into place.
Step 6: Secure Front
Securely screw the front of the receiver in place.
Power Up and Pairing
Follow these steps for powering up and pairing the receiver with the Zigbee network:
Step 1: Prepare Coordinator
Ensure the Coordinator (e.g., CO10RF) is powered up and ready for pairing.
Step 2: Power Receiver
Power up the receiver. The red LED will flash.
Step 3: Join Network
When the receiver has successfully joined the Zigbee network, the red LED will go steady.
Step 4: System Pairing
Please refer to the VS10/VS20RF manual for system pairing instructions.
Step 5: Complete Pairing
Once your system setup is complete, remember to take the coordinator out of pairing mode.
Reset and Replacement
Reset Button
If for any reason the system receiver stops operating, press the reset button and check system operation.
Replacing the System Receiver
If for any reason the system receiver needs to be removed or replaced, press the 'delete from network' function.
Technical Details
Model | RX10RF |
---|---|
Type | Wired system receiver designed for 230VAC heating applications |
Control | ON-OFF control |
Environment Ratings | |
Operating Temperature | 0 °C to +50 °C |
Storage Temperature | -20 °C to +60 °C |
Operating Humidity | 5-95 %RH |
Switch Voltage | 0-230VAC 16AMP |
Power Source | 230Vac 50Hz |
User Interface | Slide switch, Bi Colour LED, RED/GREEN |
Operating Temperature (UI) | 0 to 50 °C |
Storage Temperature (UI) | -20°C to 60°C |
Frequency | 2.4 GHz |
Approval | CE |
Warranty
SALUS Controls warrants that this product will be free from any defect in materials or workmanship, and shall perform in accordance with its specification, for a period of five years from the date of installation. SALUS Controls sole liability for breach of this warranty will be (at its option) to repair or replace the defective product.
Customer Details:
Customer Name: ..........................................................................................................
Customer Address: .......................................................................................................
..................................................................................................................................... Post Code: ...................................................
Tel No: .................................................... Email: ..........................................................
Engineer Details:
Engineers Company: ....................................................................................................
Tel No: .................................................... Email: ..........................................................
Installation Date: ..........................................................................................................
Engineers Name: .........................................................................................................
Engineers Signature: ...................................................................................................
SALUS Controls plc
SALUS House
Dodworth Business Park South,
Whinby Road,
Dodworth, Barnsley S75 3SP, UK.
SALES: T: +44 (0) 1226 323961, E: sales@salus-tech.com
TECHNICAL: T: +44 (0) 1226 323961, E: tech@salus-tech.com
SALUS Controls is a member of the Computime Group [Computime Logo]. Maintaining a policy of continuous product development SALUS Controls plc reserve the right to change specification, design and materials of products listed in this brochure without prior notice.
For PDF Installation guide please go to www.salus-controls.com
Document Reference: 00086/2 Issue Date: Dec 2016 [CE Mark] [EAC Mark]
System Overview (iT600 System)
The iT600 system integrates various components for smart heating control:
- Zigbee Coordinator (e.g., CO10RF) [Zigbee Logo]
- Wiring Centre (e.g., KL08RF)
- Internet Gateway (e.g., UGE600)
- Wireless Receiver (RX10RF)
- Thermostat (e.g., VS10/20RF)
The system supports a maximum of 6 TRVs per thermostat.
User Interface Explanation
The RX10RF receiver features a slide switch and a Bi-Colour LED (RED/GREEN).
AUTO Mode:
- The receiver output switches ON and OFF in relation to commands from the iT600 transmitter.
- RED LED only in AUTO: Indicates that there is no output from the receiver.
- RED and GREEN LED in AUTO: Indicates that there is an output from the receiver. The device connected to the receiver will be switched ON.
MANUAL Mode:
- The system receiver output is controlled by the bottom slide switch, allowing it to be permanently ON or OFF.
- The LED status in MANUAL mode is the same as in AUTO mode.
RX1 & RX2 Receiver Configuration
The RX10RF unit can be internally switched to operate as either an RX1 (Boiler Receiver) or an RX2 (Single Room Receiver). Ensure the unit is not powered during the setting of the RX1/RX2 slide switch.
Configured as RX1 (Boiler Receiver)
In this mode, the unit is wired to the boiler to switch it ON or OFF using wireless signals received from other SALUS products on the SALUS Zigbee network. The RX1 can react to signals from components such as SALUS wireless wiring centres, wireless thermostats used with SALUS wireless radiator valves, or another receiver configured as a Stand Alone receiver (RX2).
System Receiver configured to boiler receiver RX1. Refer to wiring diagrams.
Configured as RX2 (Stand Alone Receiver)
With the unit switched to RX2, it acts as a single room receiver. Its switching will be controlled by a paired SALUS VS10/20RF Thermostat. Depending on its intended use, the unit can be used to switch a motorised valve, thermal actuator, or pump.
The RX2 can also be used in conjunction with another unit set up as an RX1 (Boiler receiver). When there is a call for heat from the thermostat paired to the RX2, both wireless receivers will operate, turning on both the boiler and the motorised valve / pump.
NB: Only 1 RX1 and 1 RX2 can be used as part of a network.