Mean Well EPP-120S Series 120W Green Open Frame Power Supply
Brand: MEAN WELL
The EPP-120S series offers highly reliable green PCB type power supplies with a high power density, featuring a compact 3"x2" footprint. These units accept 80~264VAC input and provide various output voltages from 12V to 48V. They achieve up to 94% efficiency and maintain an extremely low no-load power consumption below 0.3W. The EPP-120S series is designed for compatibility with both Class I (with FG) and Class II (no FG) system designs. They incorporate comprehensive protection functions and comply with international safety regulations including TUV BS EN/EN62368-1, BS EN/EN60335-1, UL62368-1, and IEC62368-1. The EPP-120S series is positioned as a high price-to-performance power supply solution for diverse industrial applications.
Key Features
- 3"x2" Compact Size
- 120W convection, 150W peak (10sec.)
- EMI for both Class I & Class II configuration
- -30~+85°C wide range operating temperature
- No load power consumption < 0.3W
- High efficiency up to 94%
- Protections: Short circuit / Overload / Over voltage / Over temperature
- Operating altitude up to 5000 meters (Note.5)
- 3 years warranty
Applications
- Industrial automation machinery
- Industrial control system
- Mechanical and electrical equipment
- Electronic instruments, equipments or apparatus
Specifications
Parameter | EPP-120S-12 | EPP-120S-15 | EPP-120S-24 | EPP-120S-27 | EPP-120S-48 |
---|---|---|---|---|---|
DC VOLTAGE | 12V | 15V | 24V | 27V | 48V |
CURRENT (Convection) | 9.5A | 7.6A | 5A | 4.44A | 2.5A |
CURRENT (Peak, 10 sec.) | 11.8A | 9.5A | 6.25A | 5.55A | 3.125A |
RATED POWER (Convection) | 114W | 114W | 120W | 119.9W | 120W |
RATED POWER (Peak, 10 sec.) | 141.6W | 142.5W | 150W | 149.8W | 150W |
RIPPLE & NOISE (max.) Note.2 | 100mVp-p | 120mVp-p | 150mVp-p | 150mVp-p | 200mVp-p |
VOLTAGE ADJ. RANGE | 11.4~12.6V | 14.3~15.8V | 22.8~25.2V | 25.6~28.4V | 45.6~50.4V |
VOLTAGE TOLERANCE Note.3 | ±2.0% | ±2% | ±1.0% | ±1.0% | ±1.0% |
LINE REGULATION | ±0.5% | ±0.5% | ±0.5% | ±0.5% | ±0.5% |
LOAD REGULATION | ±1.0% | ±1.0% | ±1.0% | ±1.0% | ±1.0% |
SETUP, RISE TIME | 600ms, 30ms/230VAC | 600ms, 30ms/115VAC at full load | ||||
HOLD UP TIME (Typ.) | 15ms/230VAC | 15ms/115VAC at full load | ||||
VOLTAGE RANGE Note.4 | 80~264VAC | 113~370VDC | |||
FREQUENCY RANGE | 47~63Hz | ||||
POWER FACTOR | PF>0.94/230VAC | PF>0.98/115VAC at full load | ||||
EFFICIENCY (Typ.) | 91% | 92% | 93% | 94% | 93.5% |
AC CURRENT (Typ.) | 2.3A/115VAC | 1.1A/230VAC | ||||
INRUSH CURRENT (Typ.) | COLD START 30A/115VAC | 60A/230VAC | ||||
LEAKAGE CURRENT | <0.75mA/240VAC | ||||
OVERLOAD | 130~160% rated output power Protection type: Hiccup mode, recovers automatically after fault condition is removed | ||||
OVER VOLTAGE | 13.2~15.6V | 16.5~19.5V | 26.4~31.2V | 29.7~35V | 52.8~62.4V |
OVER TEMPERATURE | Protection type: Shut down o/p voltage, recovers automatically after temperature goes down | ||||
WORKING TEMP. | -30~+85°C (Refer to "Derating Curve") | ||||
WORKING HUMIDITY | 20~90% RH non-condensing | ||||
STORAGE TEMP. | -40~+85°C | ||||
ENVIRONMENT TEMP. COEFFICIENT | ±0.03%/°C (0~50°C) | ||||
VIBRATION | 10~500Hz, 2G 10min./1cycle, 60min. each along X, Y, Z axes | ||||
OPERATING ALTITUDE (Note.5) | 5000 meters | ||||
SAFETY STANDARDS | UL62368-1, TUV BS EN/EN62368-1, BS EN/EN60335-1, IEC62368-1, EAC TP TC 004 approved | ||||
WITHSTAND VOLTAGE | I/P-O/P:4KVAC | I/P-FG:2KVAC | O/P-FG:1.5KVAC | ||||
ISOLATION RESISTANCE | I/P-O/P, I/P-FG, O/P-FG: 100M Ohms / 500VDC / 25°C/70% RH |
EMC Compliance
EMC Emission
Parameter | Standard | Test Level / Note |
---|---|---|
Conducted emission | BS EN/EN55032 (CISPR32) | Class B |
Radiated emission | BS EN/EN55032 (CISPR32) | Class B, Class II: Class A |
EMC Immunity
Parameter | Standard | Test Level / Note |
---|---|---|
ESD | BS EN/EN61000-4-2 | Level 3, 8KV air; Level 3, 4KV contact |
RF field susceptibility | BS EN/EN61000-4-3 | Level 3, 10V/m (80MHz~2.7GHz) |
EFT bursts | BS EN/EN61000-4-4 | Table 9, 9~28V/m (385MHz~5.78GHz) |
Surge susceptibility | BS EN/EN61000-4-5 | Level 3, 2KV |
Conducted susceptibility | BS EN/EN61000-4-6 | Level 4, 4KV/Line-FG; 2KV/Line-Line |
Magnetic field immunity | BS EN/EN61000-4-8 | Level 3, 10V |
Voltage dip, interruption | BS EN/EN61000-4-11 | Level 4, 30A/m |
Technical Diagrams and Curves
Block Diagram
The block diagram illustrates the internal structure of the power supply. It shows the signal flow starting from the Input (I/P) which goes through an EMI Filter, then to a Rectifier & PFC stage, followed by a Switching stage. This is then processed by Rectifiers & Filter before reaching the Output (+V, -V). The diagram also indicates protection circuits such as O.T.P. (Over Temperature Protection), O.L.P. (Over Load Protection), and O.V.P. (Over Voltage Protection), all managed by a Detection Circuit. A Functional Ground (FG) connection is also present. The switching frequency (fosc) is specified as 85KHz.
Derating Curve (Convection)
This graph shows the power derating based on ambient temperature for convection cooling. The Y-axis represents Load (%) and the X-axis represents Ambient Temperature (°C). The curve indicates that the power supply can operate at 100% load up to approximately 50°C. Beyond this point, the load capacity decreases, reaching 0% load at around 85°C.
Output Derating VS Input Voltage
This graph illustrates how the output power (Load in Watts) varies with the input voltage (VAC). It displays different derating curves for specific models. For example, the 12V and 15V models (EPP-120S-12, EPP-120S-15) are rated for 114W convection, while the 24V, 27V, and 48V models (EPP-120S-24, EPP-120S-27, EPP-120S-48) are rated for 120W convection. The graph shows that the maximum rated power is maintained across a significant input voltage range, typically from 90-264VAC for the 120W models and 80-264VAC for the 114W models.
Mechanical Specifications
The power supply has overall dimensions of 76.2mm (Length) x 50.8mm (Width) x 28mm (Height), which is equivalent to 3" x 2" x 1.1". The mechanical drawing shows the layout of key components including the AC input connector (CN1), DC output connector (CN100), fuses (FS1), capacitors (C1, C5, C100, C105, C119), and heatsink (HS1). It is noted that HS1 must maintain a safety isolation distance with the system case.
AC Input Connector (CN1)
Pin No. | Assignment | Mating Housing | Terminal |
---|---|---|---|
1 | AC/L | JST VHR or equivalent | JST SVH-21T-P1.1 or equivalent |
3 | AC/N | ||
2 | No Pin |
DC Output Connector (CN100)
Pin No. | Assignment | Mating Housing | Terminal |
---|---|---|---|
1,2 | +V | JST VHR or equivalent | JST SVH-21T-P1.1 or equivalent |
3,4 | -V |
Notes
- Note 1: EPP-120S models deliver EMI Class B for both conducted emission and radiated emission when configured into a Class I (with FG) system.
- Note 2: EPP-120S models deliver EMI Class B conducted emission and Class A radiated emission with King Core K5B RC (12*15*7) in the output cable when configured into a Class II (no FG) system.
- All parameters not specially mentioned are measured at 230VAC input, rated load, and 25°C ambient temperature.
- Ripple & noise are measured at 20MHz of bandwidth by using a 12" twisted pair-wire terminated with a 0.1uF & 47uF parallel capacitor.
- Tolerance includes set up tolerance, line regulation and load regulation.
- Derating may be needed under low input voltages. Please check the derating curve for more details.
- The ambient temperature derating of 3.5°C/1000m for fanless models and of 5°C/1000m for fan models for operating altitude higher than 2000m (6500ft).
- The power supply is considered a component which will be installed into a final equipment. All the EMC tests are been executed by mounting the unit on a 360mm*360mm metal plate with 1mm of thickness. The final equipment must be re-confirmed that it still meets EMC directives. For guidance on how to perform these EMC tests, please refer to "EMI testing of component power supplies."
- Product Liability Disclaimer: For detailed information, please refer to https://www.meanwell.com/serviceDisclaimer.aspx.
Installation Manual
Please refer to: http://www.meanwell.com/manual.html
GTIN Code
MW Search: https://www.meanwell.com/serviceGTIN.aspx
Model Encoding Diagram