React Health Luna G3 CPAP/APAP Patient Quick Set-Up Guide
Button Functions
- Home Button: Return to the previous menu or main interface.
- Knob: Adjust device settings.
- Start / Stop Button: Start / Stop delivering air.
Setting up the Device
The setup involves connecting a mask to a tube, which then connects to the air outlet of the main device. The device is powered via a power adapter and power cord plugged into a power outlet. Key connection ports on the device are labeled: ① Heated Tubing Port, ② Air Outlet, ③ DC Inlet, ④ Filter Cap (Air Inlet).
- Connect one end of the tube to the assembled mask.
- Connect one end of the tube to the air outlet of the device. Alternatively, connect the heated tubing joint to the air outlet and plug the heated tubing into the heated tubing port on the back of the device.
- Connect the power adapter to the DC inlet of the main device.
- Connect the power cord to the power adapter.
- Plug the power cord into the power outlet.
Adjusting Device Settings
When the device is powered on, the Main Interface is displayed. If a heated tube is connected correctly, a specific icon (represented by a number) will appear on the screen, indicating the heated tube status.
To access the Initial Setup Interface, navigate to the relevant icon and press the [Knob]. The 'Heated Tubing' option can only be adjusted when the device is connected to a heated tube.
Use the [Knob] to select an option for adjustment.
Turn the [Knob] to adjust the selected option's value.
Press the [Knob] to confirm the adjustment for the current option.
The cursor moves between options by turning the [Knob]. Repeat steps C-E to adjust other settings. Press the [Home Button] to exit the Setup Interface.
Starting Treatment
After adjusting device settings and returning to the Main Interface, press the [Start/Stop Button] to begin treatment.
Usage Score of Luna G3 APAP (LG3600) / Luna G3 CPAP (LG3500)
After each treatment, the device provides a Usage Score (for CPAP and AutoCPAP modes) and a Usage Summary. This offers a quick understanding of the previous day's usage (from 12:00 noon to 12:00 noon). The total score is 100 points, broken down as follows:
Total Score Breakdown
Total score | Status | Display |
---|---|---|
≥ 75 | Good | iCode QR, Usage Summary (90 points, Scan to check the report) |
55-74 | Acceptable | iCode QR, Usage Summary (70 points, Scan to check the report) |
≤ 54 | Needs Improvement | iCode QR, Usage Summary (40 points, Scan to check the report) |
Scoring Components
Used Time (60 points)
Points are awarded based on treatment duration. For example, 30 minutes yields 5 points, and 1 hour yields 10 points. A maximum of 60 points can be earned.
Used time (min) | Score |
---|---|
≥390 | 60 |
360-389 | 55 |
330-359 | 50 |
300-329 | 45 |
270-299 | 40 |
240-269 | 35 |
210-239 | 30 |
180-209 | 25 |
150-179 | 20 |
120-149 | 15 |
90-119 | 10 |
60-89 | 5 |
0-59 | 0 |
Mask Seal (20 points)
Points are awarded for proper mask fit with minimal leakage. A leakage less than 10 L/min earns 20 points. For every 5 L/min increase in leakage, 5 points are deducted.
Leak (L/min) | Score |
---|---|
<10 | 20 |
10-14 | 15 |
15-19 | 10 |
20-24 | 5 |
≥25 | 0 |
Respiratory Events (20 points)
Points are awarded based on the frequency of respiratory events like apneas and hypopneas. An AHI (Apnea-Hypopnea Index) below 5 earns 20 points. For every 5-point increase in AHI, 4 points are deducted.
AHI | Score |
---|---|
<5 | 20 |
5-9 | 16 |
10-14 | 12 |
15-19 | 8 |
20-24 | 4 |
≥25 | 0 |
React Health • 5101 Fruitville Road • Suite 200 Sarasota, FL 34234 • (863) 226-6285
info@reacthealth.com • www.reacthealth.com
*React Health is formerly known as 3B Medical