Anker SOLIX Balcony Solar Power System: Safety Instructions and Datasheets

Brand: Anker

This document provides essential safety instructions and technical datasheets for the Anker SOLIX Balcony Solar Power System. It covers the microinverter, solar panels, and mounting hardware, detailing installation, operation, and safety precautions.

Lightning Surge Suppression

⚠️ WARNING: To prevent electric shock from lightning strikes, ensure all metal parts of the solar system are properly grounded. This involves scraping protective coatings from contact surfaces between the solar panel frame, brackets, and microinverter, and ensuring they are connected via conductors (e.g., metal railings) and grounded through the system's wiring.

Nearby lightning strikes can induce voltage spikes in the electrical grid, potentially damaging equipment. While the microinverter has surge protection, extreme surges can exceed its capacity. All solar installations must include surge protection, as the warranty does not cover force majeure events like lightning strikes. Install surge protection devices according to manufacturer instructions.

Solar Panel Safety

⚠️ Before installing, wiring, operating, or maintaining solar PV modules, read and understand all safety rules. Solar modules generate DC current when exposed to light. Direct contact with live parts (e.g., terminals) can cause injury, regardless of whether the module is connected.

Key precautions:

  • Maximum series fuse rating: 20A.
  • Power production tolerance: +3%.
  • Modules produce electricity when exposed to light.
  • Follow all applicable safety precautions.
  • Only qualified personnel should install or maintain modules.
  • Be aware of dangerous high DC voltage when connecting modules.
  • Do not damage or scratch the rear surface of modules.
  • Do not handle or install modules when wet.
  • Follow battery manufacturer recommendations if using batteries.

General Safety Instructions

Installers must adhere to all manual instructions, local laws, and regulations. Failure to comply voids the warranty.

Anker PV modules meet international standards. Before installation, consult local authorities for permits and inspection requirements.

Consider temperature-related voltage changes during system design. Photovoltaic modules generate power in sunlight; avoid shading from buildings, trees, or other obstructions.

Store modules in original packaging, protected from damage. Unpack carefully at the installation site. Do not drop packaged modules.

Ensure correct transport and installation methods to prevent module damage. Do not stack modules beyond specified limits.

Avoid standing, climbing, walking, or jumping on modules or their packaging. Do not place heavy or sharp objects on modules.

Use appropriate tools and supports during unpacking. Modules should not be placed in unstable environments.

Modules should be handled by two or more people with non-slip gloves. Do not carry modules by wires or junction boxes.

Store modules temporarily in a dry, ventilated environment.

Ensure modules are clean and dry before electrical contact. Do not install in rain, snow, or high winds.

Avoid artificial condensing light sources. Support structures must be durable, rust-proof, and UV-resistant, and tested/certified.

Column-mounted modules require wind and snow-resistant structures. Ensure loads do not exceed design limits.

Do not use modules with broken glass or damaged back sheets. Never attempt to disassemble or damage module components. Touching aluminum frames or surfaces can cause electric shock.

Do not step on, place heavy objects on, scratch, or damage the glass surface. Do not paint or glue the module glass.

Use opaque materials during installation to prevent shock or burns. Refrain from wearing metal jewelry during installation/maintenance.

Do not disconnect electrical connections or unplug connectors during circuit overload. Ensure cables and connectors are not scratched or cut.

Use well-insulated tools. Keep children away from the installation site.

Comply with local safety regulations for all system components (wires, connectors, inverters, batteries, etc.).

Maximum system voltage must not exceed 1000V or 1500V (check module nameplate for exact voltage).

Module output current and voltage may exceed standard test conditions. Ensure wiring and equipment can handle 1.25 times Voc and Isc.

Modules comply with IEC61215, IEC61730, CSA C22.1-12-2012, UL 1703 standards. They are Class II safety-rated.

Consult local authorities for fire safety guidelines. Roof structures and mounting brackets must be fireproof and ventilated.

Module frames must maintain a 115mm (4.5in) distance from roof surfaces for fire protection. Use appropriate accessories (fuses, breakers, earthed connectors).

Ensure roof structures are stable and sealed. Dust accumulation reduces performance; a tilt angle >10° aids self-cleaning.

Do not operate equipment panels near flammable gas.

Labels

Labels on the microinverter contain technical data, type, and serial number. Safety instructions are explained:

  • ⚠️ Danger: Issue that can cause personal injury if ignored.
  • ℹ️ Attention: Circumstances that could cause property damage if disregarded.
  • ? Instructions for use: Read and understand installation/operation instructions before use.
  • ?️? Caution, hot surface: Surfaces may be hot and pose a burn risk.
  • ♻️ Special disposal instructions: Do not dispose of with normal waste; improper disposal harms the environment.

?? CE Mark: Product complies with essential EU directive requirements.

TÜV NORD Mark: Product conformity verified by TÜV NORD, facilitating international market access.

Double-insulated appliances use reinforced protective insulation.

Microinverter Specifications (Model: A5143)

ParameterValue
Recommended PV Module Power Range (STC)(300 Wp-730 Wp+)*2
Peak Power Tracking Voltage28 V-45 V
Operating Voltage Range16 V-60 V
Maximum Input Voltage60 V
Maximum Input Current2 x 20 A
Isc PV2 x 25 A
Maximum Continuous Output Power799 VA
Nominal Output Voltage / Range230 V / 184-253 V
Nominal Output Current3.5 A
Nominal Output Frequency / Range50 Hz / 47.5 Hz-51.5 Hz
Power Factor0.99
Peak Efficiency97.30%
Nominal MPPT Efficiency99.50%
Night Power Consumption20 mW
Operating Ambient Temperature Range-40 °C to 65 °C
Storage Temperature Range-40 °C to 85 °C
Dimensions (W x H x D)263 mm x 218 mm x 36.5 mm
Weight2.8 kg
DC Connector TypeStäubli MC4 PV-ADBP4-S2&ADSP4-S2
CoolingNatural Convection - No Fans
Enclosure Environmental RatingIP67
Wire Size1 mm²
AC Extension Cable Length (Optional)5 m (Default)
Plug TypeSchuko
Communication (Inverter To ECU)Built-in Wi-Fi and Bluetooth
Isolation DesignHigh Frequency Transformers, Galvanically Isolated
Energy ManagementEnergy Management Analysis (EMA) system
CompliancesEN 62109-1/-2; EN 50549-1; DIN V VDE V 0126-1-1; VFR; UTE C15-712-1; CEI 0-21; UNE 217002; VDE-AR-N 4105

Solar Panel Specifications

Model A5500

ParameterValue
Maximum Power - Pmax (W)415
Open Circuit Voltage - Voc (V)37.45
Short-Circuit Current - Isc (A)14.02
Voltage at Pmax - Vmp (V)31.61
Current at Pmax - Imp (A)13.13
Module Efficiency21.3%
Power Tolerance (W)(0, +4.99 W)
Maximum System Voltage (V)1500 Vdc (IEC)
Maximum Series Fuse Rating (A)25 A
External Dimensions1722 x 1134 x 30 mm
Weight20.5 Kg
Solar CellsMonocrystalline 108 (2x54)
Front GlassAR Coated 3.2 mm tempered glass
FrameAnodized aluminum alloy
Junction BoxIP68
ConnectorMC4 Compatible
Mechanical Load (Front/Rear)Max. 5400 Pa / Max. 2400 Pa
Pmax Temperature Coefficient-0.350%/°C
Voc Temperature Coefficient-0.275%/°C
Isc Temperature Coefficient+0.045%/°C
Operating Temperature-40~+85 °C

Model A5507

ParameterValue
Maximum Power - Pmax (W)445
Open Circuit Voltage - Voc (V)40.09
Short-Circuit Current - Isc (A)13.69
Voltage at Pmax - Vmp (V)33.91
Current at Pmax - Imp (A)13.13
Module Efficiency22.8%
Power Tolerance (W)(0, +5 W)
Maximum System Voltage (V)1500 Vdc (IEC)
Maximum Series Fuse Rating (A)25 A
External Dimensions1722 x 1134 x 30 mm
Weight22.2 Kg±3%
Solar CellsMonocrystalline 108 (6x18)
Front GlassClass II
FrameAnodized aluminum alloy
Junction BoxIP68
ConnectorMC4 Compatible
Mechanical Load (Front/Rear)Max. 5400 Pa / Max. 2400 Pa
Pmax Temperature Coefficient-0.290%/°C
Voc Temperature Coefficient-0.242%/°C
Isc Temperature Coefficient+0.054%/°C
Operating Temperature-40~+85 °C

Solar Panel Tilt Mount (A5650) Specifications

ComponentSize (mm)Net Weight (kg)
U-shaped Rack217*45*1.50.1
Vertical Support Scaffolding1100*110*1.51.34
Solar Panel Support Beam1200*108*1.51.38
Lower Support Beam618*102*1.50.73
Fastening Clamp130*48*1.50.07
Limit Supports92*40*20.05

Installation and Maintenance

Installation: Ensure panels can extend beyond balcony railings. Check local authorities for installation permits. Install/remove with caution, keeping the area below clear. At least two people are recommended for installation/removal. Secure panels firmly before tightening clamps. Use mounting auxiliary rope. Handle panels carefully to avoid damage.

Electrical: All installations must comply with local electrical codes. Provide additional protection for AC wiring (RCDs, circuit breakers). Product may cause AC current with DC component; use Type B RCD/RCM if applicable. No internal modifications to microinverter except cable connectors. Never disconnect panels from microinverter without turning off AC power. Do not disconnect connectors under load.

Mounting Brackets: Designed for wind force level 8. Additional measures may be needed in extreme winds (e.g., temporary removal). Address rust or deformation immediately with protective measures.

Maintenance: Do not damage panels with sharp objects. Keep panels uncovered for maximum sunlight. Never disconnect DC connectors under load. Avoid touching hot surfaces of the microinverter. Do not attempt to repair the microinverter; contact authorized service agents if troubleshooting fails.

Notice: CE RED Declaration of Conformity is available at https://www.anker.com. Product complies with EU radio interference requirements (Directive 2014/53/EU).

Warranty and Disclaimers

Disclaimers: The limited warranties provided are exclusive and replace all other express or implied warranties, including warranties of merchantability and fitness for a particular purpose. Some jurisdictions may not allow warranty exclusions.

Warranty Periods:

  • Anker RS40 Rigid Solar Panel: 12 Years
  • Anker SOLIX RS40P Rigid Solar Panel (445W): 15 Years
  • Anker SOLIX MI80 Microinverter (800W BLE): 12 Years
  • Anker Adjustable Solar Panel Tilt Mount: 2 Years
  • Anker Solar Panel Extension Cable & MI to Schuko Connection Cable: 1 Year
Models: A5143 SOLIX RS40P 600W 800W Balcony Solar Power System, A5143, SOLIX RS40P 600W 800W Balcony Solar Power System, 800W Balcony Solar Power System, Balcony Solar Power System, Solar Power System, Power System

File Info : application/pdf, 23 Pages, 1.63MB

PDF preview unavailable. Download the PDF instead.

SAFETY INSTRUCTIONS AND DATASHEETS ?v=1693481961

References

ConvertAPI

Related Documents

Preview Anker SOLIX Return Policy and Warranty Information
Detailed return policy and warranty periods for Anker SOLIX solar panels, power stations, microinverters, and accessories. Learn about the 14-day money-back guarantee, contact information, and the process for returns and refunds.
Preview Anker SOLIX 405W Rigid Solar Panel User Manual | Installation & Safety Guide
Comprehensive user manual for the Anker SOLIX 405W Rigid Solar Panel. Includes technical specifications, safety instructions, connection guides, and installation steps for optimal performance and safe operation.
Preview Anker SOLIX 400W Foldable Solar Panel (PS400) - Technical Specifications and Features
Detailed information on the Anker SOLIX 400W Foldable Solar Panel (PS400), including its high-efficiency monocrystalline cells, ETFE coating, IP67 water resistance, MC4 connectors, and foldable design for portability. Learn about its specifications, benefits, and applications for various power needs.
Preview Anker SOLIX PS100 Portable Solar Panel User Guide
Instructions and specifications for the Anker SOLIX PS100 100W Portable Solar Panel, detailing setup, charging, and technical specifications for optimal use.
Preview Anker SOLIX Solarbank 2 E1600 AC Quick Installation Guide
This guide provides step-by-step instructions for installing and setting up the Anker SOLIX Solarbank 2 E1600 AC solar power system. It covers system design, electrical connections, mounting, optional accessories like the Smart Meter and Smart Plug, app usage, and operational modes.
Preview Anker SOLIX Solarbank 2 E1600 AC Quick Installation Guide
A comprehensive guide detailing the installation process for the Anker SOLIX Solarbank 2 E1600 AC, including system design, electrical connections, safety precautions, and optional accessory setup for smart metering and smart plug integration.
Preview Anker SOLIX PS100 Portable Solar Panel: Usage Guide and Specifications
Learn how to use the Anker SOLIX PS100 100W portable solar panel, including setup, charging instructions, important notes, and detailed specifications for optimal performance.
Preview Anker SOLIX PS200 Portable Solar Panel User Guide
Instructions and specifications for the Anker SOLIX PS200 Portable Solar Panel, detailing setup, charging, and performance characteristics for optimal solar energy capture.