EuroSwitch 5 Inputs - 4 Outputs
Compact and effective for large installations.
A compact multiswitch with 5 inputs (1 terrestrial and 4 SAT) and 4 subscriber outputs. Features very low through and branch attenuation due to its construction, reducing the need for amplifiers in a cascade without compromising signal quality, even in large installations. Can be used as a standalone switch (star topology) or as a cascade switch. Additionally, TForce technology can be activated to automatically adjust the terrestrial signal, ensuring a constant signal despite reception fluctuations. RED compliant.
Product Details
Ref. No. | 719501 |
Art. No. | MSE54C |
EAN13 | 8424450246696 |
Packaging
Carton | 1 pc. |
Physical Data
Net weight | 362.00 g |
Gross weight | 426.00 g |
Width | 137.00 mm |
Height | 120.00 mm |
Depth | 30.00 mm |
Component weight | 362.00 g |
Highlights
- Very compact design and low weight, even for models with a high number of subscribers.
- Very low through and branch attenuation.
- Very good shielding: Class A. Die-cast housing developed and manufactured by Televes.
- Very flexible: Due to switchable termination resistors for every individual or cascade switch.
- High decoupling between inputs and outputs.
- Equipped with TForce technology, which automatically adjusts the terrestrial output level (TERR. AMP. ACTIVE) to the optimal level.
- 10 dB attenuation switch (Low Gain (LG) / High Gain (HG)) for each group of 8 subscriber outputs.
- Multiple power supply options: Via an external power supply, via SAT connections in a cascade setup, or directly from the SAT receiver (RECEIVER POWER ACTIVE).
- Low power consumption in normal operation. Additionally, there is an ECO mode where power consumption decreases with a lower number of connected users.
- 12-18V power supply range.
- Current circulation between all inputs and cascades.
- Inputs and through-loop outputs are color-coded.
- 100% European design, quality, and manufacturing.
Application Example
Example for a single-family home with 1 Satellite.
The LNB and multiswitch are supplied via the subscriber output through a receiver or an insertion switch. An external power supply is not required.
Diagram Description: The diagram shows a setup with a DTT antenna and two SAT inputs connected to a Televes multiswitch (MSW 5x5x4). The multiswitch has outputs for TV and STB. The configuration settings for the multiswitch are indicated: TERR. DC = OFF, RECEIVER POWER = ON, TERR. AMP. (T.Force) = PASSIVE, AUTOLOAD = TERMINAL. A DC flow from the STB is also indicated.
Application Example for a Residential Building with 1 Satellite
The LNB, the terrestrial antenna, and the multiswitch cascade system are supplied by a single 3A power supply. Through the "Receiver power" switch, the receivers are DC decoupled from the cascade, thus protected against overvoltage.
Diagram Description: This diagram illustrates two different configurations for a residential building with 1 satellite. The first configuration shows a multiswitch (MSW 5x5x16) connected to multiple TVs and STBs, with settings: TERR. DC = ON, RECEIVER POWER = OFF, TERR. AMP. (T.Force) = ACTIVE, AUTOLOAD = CASCADE. It indicates a DC flow from a 3A PSU (Ref. 732802). The second configuration also uses an MSW 5x5x16 multiswitch connected to multiple TVs and STBs, with settings: TERR. DC = OFF, RECEIVER POWER = OFF, TERR. AMP. (T.Force) = ACTIVE, AUTOLOAD = TERMINAL. It also shows a DC flow from a PSU.
Technical Specifications: Ref. 719501
Inputs | 5 |
Cascade outputs | 5 |
Subscriber outputs | 4 |
Frequency range TERR. | 88 ... 862 MHz |
Frequency range SAT. | 950 ... 2400 MHz |
Input level TERR. | 80 ... 110 dBμV |
Input level SAT. | 65 ... 112 dBμV |
Through attenuation TERR. | < 2 dB |
Through attenuation SAT. | < 2 dB |
Subscriber attenuation TERR. Active | 0 ... 4 dB |
Subscriber attenuation TERR. Passive | 32 dB |
Subscriber attenuation SAT. HG | 2 ... 7 dB |
Subscriber attenuation SAT. LG | 12 ... 14 dB |
Output voltage 10Ch DVB-T | 78 dBμV |
Decoupling H/V | > 50 dB |
TN decoupling | > 30 dB |
Power supply | 12 ... 18 Vdc |
Max. current consumption (PSU - TERR ACT.) | 65 mA *1 |
Max. current consumption (PSU - TERR PAS.) | 5 mA |
Max. current consumption (STB) | 85 mA |
Operating temperature | -5 ... 45 °C |
Protection index (IP) | 20 |