VX Series Energy Management Thermostat

Model: VX-TL-KT-W Wireless Energy Management Thermostat With Lighting Control

The Verdant VX-TL-KT thermostat delivers unprecedented energy savings without compromising guest comfort.

New energy efficient building codes have raised the energy performance standards required of commercial buildings.

California's Title 24 (Part 6) building code as well as other state building codes founded upon IECC 2015 or 2018 energy efficiency codes have now mandated occupancy-based control of heating and air-conditioning, lighting, outside air dampers, and/or receptacles.

The Verdant VX-TL-KT thermostat reduces HVAC runtime by dynamically setting back temperature in empty rooms, without disturbing the comfort of occupants.

The thermostat can also shut off power to a lighting circuit by using an external relay that receives the thermostat's occupied/unoccupied signal.

The occupied/unoccupied signal can be configured to be Normally Open (NO) or Normally Closed (NC). This provides unsurpassed flexibility when connecting to other systems like outside air dampers or exhaust fans.

The Verdant Thermostat and Verdant HVAC Controller communicate wirelessly for a simple and effortless installation. The Verdant HVAC Controller connects to the HVAC unit using standard thermostat terminals (7 wires). In the case of a mini split or VRF unit, Verdant Sales should be contacted for the applicable part number.

The Verdant thermostat is powered at 24VAC in order to provide the required voltage for the occupancy output signal.

Verdant's combined solution offers building owners a cost effective energy management system that can be deployed with minimal accessories, and little to no extra labor, making it simple to install.

Building Code Compliance

The VX-TL-KT thermostat facilitates building-code compliance by addressing the following requirements:2†

IECC 2015

  1. C405.2.4.3 Specific application controls for sleeping units.

IECC 2018

  1. C.403.7.6 Automatic Control of HVAC system serving guestrooms integrally.
  2. C405.2.4.2 Specific application controls for sleeping units

Title 24 Part 6

  1. Section 130.1(c)8 Shut-off controls for Hotel/Motel guestrooms.
  2. Section 120.2(e) Shut-off and Reset Controls for Space-conditioning Systems
  3. Section 130.5(d) Circuit Controls for 120V Receptacles and Controlled Receptacles.

Product Components

ItemPart #Description
Thermostat with display showing "72°F" and fan/cool iconsVX-TL-W*Verdant Thermostat with Lighting Control Capabilities
Rectangular white box with terminal connectionsAC-CCVerdant HVAC Controller
Small white circular sensorX9-RF-OSVerdant Wired Occupancy Sensor

* Also available in black. For black, replace W with B.

1 Requires a network access license for each thermostat (Part Number: XMF) and one "Online Connection Kit" (Part Number: OL-KT). Additional fees apply.

2 In jurisdictions where building code mandate any of the undermentioned measures, additional software licenses (Part Number: XMF) and one (1) Online Connection Kit are required. Additional fees apply.

Buyer is solely responsible for determining the suitability of product for Buyer or end user's specific application and equipment. Information provided regarding compliance with any regulation is not to be construed as a warranty or guaranty, express or implied. Responsibility for component and equipment selection, code compliance, install, configuration, use and maintenance of Product remains solely with Buyer and end-user.

VX Series Technical Specifications

Wiring Diagram: Verdant HVAC Controller

This diagram illustrates the wiring connections for the Verdant HVAC Controller. On the left, the HVAC Unit connections are shown with terminals for Auxilary, Fan Low (PU), Fan High (GR), Compressor (YE), Reversing Valve (OR), Auxilary Heater (WH), 24 VAC (RD), and Common (BK). These connect to the Verdant HVAC Controller, which has corresponding terminals: C (COMMON), R (24V), Y (COMPRESSOR), W (HEAT), O or B (REVERSE VALVE), GH (FAN HIGH), and GL (FAN LOW). All connections are 20 AWG.

Wire ColorTerminal LetterTerminal Connection
BLACK (BK)CCOMMON
RED (RD)R24V
YELLOW (YE)YCOMPRESSOR
WHITE (WH)WHEAT
ORANGE (OR)O or BREVERSE VALVE
GREEN (GR)GHFAN HIGH
PURPLE (PU)GLFAN LOW

Wiring Diagram: Verdant Thermostat

This diagram shows the wiring for the Verdant Thermostat and Verdant Occupancy Sensor. The Verdant Thermostat connects to the Verdant Occupancy Sensor (OS) wirelessly via 900MHz. The thermostat also has connections for RC, R1, XF MR1, and a 20 AWG connection for power feed from line voltage. An external relay (R1) is shown, which can be connected to a controlled lighting circuit and a controlled receptacle, receiving signals from the thermostat.

Bill of materials VX-TL-KT-W

ItemDescriptionPart Number
1Verdant HVAC ControllerAC-CC
2Verdant ThermostatVX-TL-W
3Verdant Occupancy SensorX9-RF-OS

* Also available in Black. For Black replace W with B.

Product Specifications

ThermostatHVAC ControllerOccupancy Sensor
Case Dimensions (Imperial)4.02 x 5.51" x 0.93"3.88" x 2.13" x 0.75"2.5" x 3.5" x 0.73"
Case Dimensions (Metric)102mm x 140mm x 23.5mm98mm x 54mm x 19mm63.5mm x 88.9mm x 18.5mm
Screen Dimensions (Imperial)3.63" x 2.13"N/AN/A
Screen Dimensions (Metric)92mm x 54mmN/AN/A
Operating Voltage24VAC24VAC24VAC
Control OutputsOccupancy Out (Aux)Fan High (GH), Fan Low (GL), Compressor (Y), Heat Pump (OB), Heat (W)
Occupancy Sensor Beam Width±47° (94°)N/A±47° (94°)
Wireless Frequency902-928MHz902-928MHzN/A
Temperature Accuracy±1°FN/AN/A
FCC IDXEYWXXEYV8ACCCN/A
IC8410A-WX8410A-V8ACCCN/A

Typical HVAC Applications

Regulatory Compliance

FCC Compliance Statement: This device complies with Part 15 of the FCC Rules. Operation is subject to the following two conditions: (1) This device may not cause harmful interference, and (2) this device must accept any interference received, including interference that may cause undesired operation.

Pursuant to Part 15.21 of the FCC Rules, any changes or modifications to this equipment not expressly approved by Verdant Environmental Technologies, Inc. may void the user's authority to operate the equipment.

US Patents: 8,369,994; 8,141,791; 7,918,406; 7,841,542; 7,838,803; RE40,437; 7,232,075; 7,185,825; 7,156,318; 7,152,806; 7,145,110; 7,058,477; 7,050,026; 7,028,912; 6,902,117; 6,789,739; 6,786,421; 6,619,555; 6,581,846; 6,578,770.

Canadian Patents: CA2615065; CA2633113; CA2633121; CA2633200; OTHER PATENTS PENDING.

Verdant Energy Management Solutions reserves the right to make changes, without notice, in design or components as progress in engineering and manufacturing methods may warrant. Product appearance may vary.

© Verdant Energy Management Solutions, 2020

080221 Emerson is a trademark of Emerson Electric Co. ©2021 Emerson Climate Technologies, Inc. All rights reserved.

EMERSON. CONSIDER IT SOLVED.

PDF preview unavailable. Download the PDF instead.

VX-TL-KT-W Adobe PDF Library 15.0 Adobe InDesign 15.1 (Windows)

Related Documents

Preview Verdant VX3-TW-W-LIT Wireless Energy Management Thermostat with Lighting Control
Information on the Verdant VX3-TW-W-LIT Wireless Energy Management Thermostat, featuring easy-to-use controls, unparalleled energy savings, auxiliary output for occupancy-based control, and compliance with energy efficiency codes like Title 24 and IECC 2015/2018.
Preview Verdant VX Series VX-TW-KT-W Wireless Energy Management Thermostat
Explore the Verdant VX Series VX-TW-KT-W Wireless Energy Management Thermostat, offering unparalleled energy savings, guest comfort, and easy installation with online management capabilities. Ideal for various HVAC applications.
Preview Verdant VX Series Wireless Thermostat Installation Manual
Installation manual for the Verdant VX Series Wireless Thermostat with Occupancy Sensor, detailing setup, configuration, and operation for optimal energy management in hospitality environments.
Preview Verdant VX Series VX-TW-KT-W Wireless Energy Management Thermostat
Discover the features and technical specifications of the Verdant VX Series VX-TW-KT-W Wireless Energy Management Thermostat, focusing on energy savings, guest comfort, and advanced control capabilities.
Preview Verdant VXDB-TW-KT-W VX Series Wireless Thermostat Installation Manual
Comprehensive installation manual for the Verdant VXDB-TW-KT-W VX Series Wireless Thermostat with Occupancy Sensor. Covers network setup, thermostat configuration, accessory management, and troubleshooting for efficient HVAC energy savings.
Preview Verdant VX Series VX3-TW-KT-W Wireless Energy Management Thermostat
Explore the Verdant VX Series VX3-TW-KT-W Wireless Energy Management Thermostat, designed for unparalleled energy savings and uncompromising guest comfort. Features include occupancy sensing, night occupancy mode, and online management capabilities.
Preview Verdant VX Series Thermostat: Features and Installation Guide
Explore the features of the Verdant VX Series thermostat, including energy savings, guest comfort, and installation options. This guide provides wiring tables for 24V AC and 24V DC systems, along with product specifications.
Preview Verdant ZX Series ZX-TW-KT Wireless Energy Management Thermostat Specifications
Detailed specifications for the Verdant ZX Series ZX-TW-KT Wireless Energy Management Thermostat, highlighting features like energy savings, occupancy sensing, wireless connectivity, and typical HVAC applications.