Description
DEFA Power is a premium charging station for electric vehicles and plug-in hybrids. The charging station has been created with the user in mind. Smart features, simple set-up, and powerful functionality, such as full dynamic load balancing and active phase rotation, characterize the device. The charging station can be installed directly onto a wall or a pole, indoors or outdoors.
Key Features:
- Precise load balancing: Utilizes all available power, independent of cloud connection.
- Effective cooling: No derating ensures maximal charging power.
- Active phase rotation: Utilizes power on all phases.
- Intuitive display: Information and status sharing with the user.
- Small and compact: Fits everywhere and can easily be installed and handled.
- For everyone: Handles all power and phase needs in European markets.
- Plug and play: Easy installation, setup, and configuration via app.
- Powersmart: Minimizes charging cost by utilizing spot market energy prices and planning of charging curve.
A self-test of the built-in RDC-DD is performed in every charging start-up cycle and every 24 hours. If the built-in RDC-DD is tripped, a clear error message will be displayed on the screen. To reset the built-in RDC-DD, unplug the charging cable from the vehicle and then plug it in again.
Safety Information
Important! Read this document before using the device. Failure to follow any of the instructions or warnings can result in material damage or personal injury.
Important! If the device fails to behave according to instructions, immediately contact an electrician, responsible vendor, or DEFA. See chapter Contact information.
Important! DEFA Power must be installed, uninstalled, or repaired by a licensed electrician. These actions must be executed in accordance with national and local regulations.
DANGER: Sections marked with this symbol [⚡] draw attention to electrical voltages that represent a danger to life and limb. Actions contrary to these safety notices may lead to severe or fatal injury. Actions contrary to these safety notices must not be carried out under any circumstances.
WARNING: Sections marked with this symbol [⚠️] draw attention to additional hazards that may lead to damage to the cable itself or to other electrical devices. Actions marked with this symbol must be carried out with special care.
NOTICE: Sections marked with this symbol [ℹ️] draw attention to additional important information and special features that are necessary for the reliable operation of the device. Actions marked with this symbol should be carried out as required.
General Danger and Warning Information
Danger: Do not use if the outer shell has been damaged.
Danger: Do not use the cable if it is defective or appears cracked, broken, or otherwise damaged.
Danger: Do not use adapters or extension cords.
Warning: Physical repairs must be executed by a licensed electrician.
Warning: Changes to the settings or the power connections must be executed by a licensed electrician.
Warning: The product is designed only for Mode 3-charging of vehicles. Do not use it for any other purpose.
Warning: Do not allow the cable to be under strain during charging.
Warning: Do not allow water to enter the charging port while charging.
Warning: Keep the plug and charging station away from water. Do not expose to a direct jet or splashes of water.
Handling: Ensure that the cable is never run over by a vehicle.
Handling: Handle the cable with care and do not subject it to strong force or impact. Do not pull, twist, tangle, drag, or step on the cable or plug.
Handling: Always hold the cable by the plug when pulling it. Do not pull the cable itself.
Sorting and Storage
See chapter Store and protect for information about how to coil the cable correctly.
- Always store the product with the cable coiled. Do not leave the cable on the ground after usage.
- Attach the plug cap to protect the vehicle plug when the product is not in use.
- Use the cable clip to coil the cable for when the product is not in use.
Main Parts
Diagram showing the main components of the DEFA Power charging station:
- A. Charging unit
- B. Display
- C. RFID-reader
- D. Cable clip
- E. Plug
- F. Plug cap
- G. Cable
- H. Wall bracket
- J. Locking tool
- K. Rating label (public key)
Symbols on the Display
The display shows various status indicators:
- Charging station available in setup mode: Only visible a short period.
- Charging station ID: Unique identifier for the station.
- Main icon: Charging is ongoing
- Active charging output in kW: Current power delivery.
- User ID: Identifier for the user.
- Charging voltage, number of phases and current (A): Electrical parameters of the charge.
- Status message: Textual feedback on the charging status.
- kWh used since first start charging: Total energy delivered.
- Downloading FW update: Only visible during downloading.
- Network connection: Indicates connection status.
- Duration of charging: Time elapsed since charging started.
- Amount of kWh charged so far this session: Energy delivered in the current session.
- SW version: Software version of the charger.
- Color frame indicates main status: Visual cue for the overall status.
Initialization, Charging, and Error States
Initialization States:
- READY: Charger Ready. The charger is unlocked and ready to use.
- SCAN QR: Charger Ready. Scan the QR-code and follow instructions to start charging (typically for facility-based chargers).
- SCAN QR/RFID: Vehicle connected (access control enabled). Scan QR-code or RFID-card to start authorization.
- Authorizing: Authorization is in progress.
- NO ACCESS: Access denied. The authorization was denied.
Charging States:
- PREPARING: Preparing charging. The charging process is initialized.
- CHARGING: Charging. The vehicle is charging.
- DONE OR PAUSED: Done or paused. The charging process is done or paused.
- DONE: Once the cable is disconnected, a summary of the charging process is shown.
Errors and Configuration:
- Error: Scan QR: Scan the QR-code on the display and follow instructions to troubleshoot.
- Error: Contact support phone: Call the displayed number to troubleshoot (for facility chargers).
- Error: Contact CPO: Contact your charge point operator for support.
- Authorization: No access: Check your user application or contact customer support.
- Configuration: Application Running: The configuration application is running.
- Configuration: Scan QR to setup: Scan the QR code on the display to initialize setup.
Charging Procedure
NOTICE: Please read the charging instructions in the vehicle's manual before using the charging station.
WARNING: The plug locks to the vehicle inlet when charging starts. The plug stays locked until the charging procedure is finished. Always complete or end charging in the vehicle before unplugging (refer to the vehicle's charging instruction for information about this).
Plug In:
- Pick up the plug, uncoil the cable, and remove the plug cap.
- Make sure that the charger is ready to be used. The Charger Ready icon [✅] should be visible on the display.
- Insert the plug into the vehicle inlet. The following symbol [⚡] should now be visible on the display to indicate that charging is initialized. If authorization is enabled, that process has to finish before charging can begin. See the chapter Authorization for more information.
- Make sure that charging has started. The following symbol [?] should now be visible on the display.
NOTICE: The plug must be fully inserted into the inlet of the vehicle. Failure to connect will prevent the vehicle inlet from locking the plug in place and start charging.
Troubleshooting, Store and Protect, Maintenance and Care
Troubleshooting:
The following symbols indicate that there has been an issue. In order to fix the issue, scan the QR-code on the screen and follow the instructions on the web page, or contact support.
- Error: Contact electrician
- Error: Contact CPO
- Authorization: No access
Store and Protect:
Coil the cable:
Roll the cable around the charging unit. Make sure that the plug hangs with the plug cap facing the ground. Attach the clip to the cable.
Use the plug cap:
The plug strap can adjust the cap's position. This prevents the cap from collecting water and dirt, and keeps the cap clear of the vehicle.
Maintenance and Care:
WARNING: Do not flush water on the charging station. Do not use harsh chemicals when cleaning.
Checking:
- Keep the plug dry and check regularly for dust, dirt, pebbles, etc.
- Check the cable regularly for cracks and other damage.
Cleaning:
- Use a damp cloth to clean. Do not use water or harsh chemicals.
Contact Information and Technical Specification
Contact Information:
If you have any questions, contact your local vendor or visit defa.com. If you have any feedback on how the system or support can be improved, feel free to give us your input at defa.com.
Technical Specification:
Item number | 715000 |
---|---|
Rated voltage | 380-420Vac (Three phase, 50-60Hz) 220-240Vac (Single phase, 50-60Hz) |
Charger type | Mode 3 |
Connection to vehicle | Type 2 |
RDC-DD | 6mA DC in acc. IEC 62955 |
GRID type | TN/IT/TT |
Overheat protection | Internal sensor |
Operating temperature | -40°C to +50°C |
Storage temperature | -50°C to +85°C |
Size (L x W x T) | 113 x 167 x 350 mm |
Material control box | Plastic |
IK rating | IK 10 |
IP rating | IP 55 (Wallbracket IP44) |
Weight | 5.0 kg |
Certification | CE, IEC61851, IEC62955 |
Recycling | EE-waste [♻️] |
DEFA AS hereby declares that this product (Product Name: DEFA Power™, Model Name: DEEVC/CT2/22 & DEEVC/WB480/22) is compliant with the essential requirements and other related provisions of Directive 2014/53/EU.
The product has two labels: the unit label named DEFA Power Up and the bracket label named DEFA Power Ready. The end product model name is combined with these two type names, resulting in DEFA Power™.
Radio information: [ℹ️]
CE marking: [CE]