Bertazzoni DW24S3IPV Dishwasher Installation Specifications
Product Dimensions
Side View: The dishwasher has an adjustable height ranging from 32 1/4 inches (820 mm) to 34 1/4 inches (870 mm), with an additional 2 inches (50 mm) for feet adjustment. The width is 21 5/8 inches (550 mm). The overall depth is 45 2/3 inches (1160 mm), which includes a 3/4 inch (20 mm) thick custom panel.
Front View: The visible width is 23 9/16 inches (598 mm), and the height is 25 1/2 inches (647 mm).
Top View: The width is 23 9/16 inches (598 mm), and the depth is 21 5/8 inches (550 mm). This view indicates the locations for WATER DRAIN, WATER INLET, and POWER connections. It also specifies a minimum cabinet depth requirement of 3 1/8 inches (80 mm) to a maximum of 5 1/8 inches (130 mm) for the drain hose and toe kick area, which are provided with the unit.
Cutout Dimensions
Side View: The required height for the cutout ranges from 32 1/2 inches (824 mm) to 34 3/8 inches (874 mm).
Front View: The cutout width can be 24 inches (610 mm) or 23 5/8 inches (600 mm). The choice depends on whether vertical side trims are installed (* with vertical side trims installed) or not (** without vertical side trims).
Top View: The cutout depth is 25 inches (635 mm). Note *** clarifies that this cabinet depth includes the kitchen cabinet front panel. For a flush installation, a minimum inset depth of 22 1/2 inches (570 mm) is necessary, assuming a custom door panel thickness of 3/4 inch (20 mm).
Electrical & Water Connection
Electrical: A properly-grounded, horizontally-mounted electrical receptacle must be installed according to the provided drawing. The diagrams indicate 'EW' (Electrical/Water) connection points.
Water: To connect to the water inlet valve, use a 3/8 inch water inlet hose and a 3/4 inch metal adapter with a length of 60 inches (1524 mm) (not supplied). The diagrams also show 'EW' connection points. Connections placement must be on either side of the cutout.
Installation Requirements
Follow local codes and ordinances for drain requirements. Install a waste line with an air gap (not supplied). Alternatively, a high drain loop of at least 30 inches (762 mm) is recommended to prevent backflow. The drain hose is 74 inches (1880 mm) long and must be connected at a minimum height of 20 inches (508 mm) from the floor.
Dimensions in parentheses are millimeters unless otherwise specified.
Custom Panel Requirements
Door tension can be adjusted to accommodate custom panel weights from 7 lb (3 kg) to 18 lb (8 kg). For custom panels weighing between 18 lbs (8 kg) and 22 lbs (10 kg), the optional Heavy Duty Springs kit HS24DW must be purchased. The suggested panel thickness is 3/4 inch (20 mm).
The dimensions for a custom panel are: height from 25 1/2 inches to 28 1/4 inches (647-717 mm) and width from 23 5/16 inches to 23 7/16 inches (592-596 mm).