CAME FROG Swing-Gate Operator

Installation Manual

Model Series: FROG-A, FROG-AV, FROG-AE

Document Code: FA01316-EN

General Precautions for Installers

⚠️ Important safety instructions. Follow all of these instructions. Improper installation can cause serious bodily harm.

Before continuing, also read the general precautions for users. Use this product only for its specifically intended use. Any other use is hazardous. The manufacturer cannot be held liable for any damage caused by improper, unreasonable, and erroneous use.

This product is defined by the Machinery Directive 2006/42/CE as partly-completed machinery. It is intended to be incorporated or assembled into other machinery to build a complete system regulated by the Machinery Directive 2006/42/EC. The final installation must comply with this directive and current European reference standards.

The manufacturer declines liability for using non-original products, which would void the warranty. All operations must be carried out exclusively by skilled and qualified personnel in full compliance with current regulations.

Laying of cables, installation, and testing must follow state-of-the-art procedures as dictated by applicable standards and laws.

Ensure the mains power supply is disconnected during all installation procedures. Check that temperature ranges match the location. Add suitable reinforcements to anchoring points if necessary.

Ensure the operator is protected from direct water jets (sprinklers, water cleaners). Install a suitable dual-pole cut-off device compliant with installation rules, capable of completely cutting off the power supply according to category III surcharge conditions.

Demarcate the site to prevent unauthorized personnel, especially children and minors, from entering. For manual handling, ensure one person per 20 kg. Use proper hoisting equipment for non-manual handling.

Use suitable protections to prevent mechanical hazards from people within the operator's operating range. Electric cables must pass through special pipes, ducts, and cable glands for adequate protection against mechanical damage. Ensure electrical cables do not touch parts that may overheat during use.

Before installation, check that the guided part (gate) is in good mechanical condition and operates correctly. The product cannot automate guided parts that include a pedestrian gate unless the pedestrian gate can be enabled only when secured.

Ensure people cannot be entrapped between the guided and fixed parts when the gate is in motion. All fixed controls must be clearly visible after installation, positioned to allow direct visibility of the gate but far from moving parts. Maintained action commands must be installed at a minimum height of 1.5 m from the ground and not be accessible to the public.

If not already present, apply a permanent tag describing how to use the manual release mechanism close to the mechanism. Ensure the operator is properly adjusted and that safety devices and the manual release are working correctly.

Before handover to the final user, verify the system complies with harmonized standards and essential requisites of Machinery Directive 2006/42/CE. Indicate any residual risks clearly with proper signage in visible areas and explain them to end users. Fit the machine's ID plate in plain sight upon completion of the installation.

Danger Information

If the power-supply cable is damaged, it must be immediately replaced by the manufacturer, an authorized technical assistance center, or qualified staff to prevent any risk. Keep this manual inside the technical folder along with manuals of all other devices used for your automation system. Hand over all operating manuals of the products that make up the final machinery to the end users.

Main Points of Danger for People

The following diagram illustrates key danger zones:

  • ? Do not transit through during maneuvering.
  • ⚠️ Danger of entrapment.
  • ⚠️ Danger of hand entrapment.
  • ⚠️ Danger of foot entrapment.

Product Data and Information

Legend

  • [Read Carefully Symbol]: This symbol shows which parts to read carefully.
  • [Safety Issues Symbol]: This symbol shows which parts describe safety issues.
  • [Tell Users About Symbol]: This symbol shows which parts to tell users about.

The measurements, unless otherwise stated, are in millimeters.

Description

The CAME FROG is an irreversible ground-concealed gearmotor for swing gates:

  • For gates up to 3.5 m in length per leaf, with adjustable leaf-closing.
  • (Fast Version) For gates up to 1.3 m in length per leaf, with adjustable leaf-closing.
  • For gates up to 3.5 m in length per leaf, with adjustable leaf-closing.

Intended Use

This is an ideal below-ground solution for automating residential and apartment-block gates. Any installation and/or use other than that specified in this manual is forbidden.

Description of Parts

  1. Gearmotor
  2. Movement transmission lever
  3. Gearmotor arm
  4. Screw for adjusting the closing limit-switch point
  5. Screw for adjusting the opening limit-switch point
  6. Lever for hooking the release unit
  7. Brace for fastening to gate
  8. Foundation box
  9. Cover
  10. Fastening hardware

Dimensions and Technical Data

Dimensions

The unit has the following approximate dimensions: Overall length 340 mm, width 145 mm, height 200 mm. Side view shows a length of 226 mm and a height of 144 mm.

Limits to Use

It is always advisable to install an electric lock to ensure reliable closure of the gate. Installation of an electric lock is mandatory for irreversible gearmotors and for gate leaves longer than 2.5 m.

Technical Data

MODELSFROG-AFROG-AEFROG-AV
Gate-leaf length (m)3.52.523.52.521.3
Gate-leaf weight (Kg)*400*600800*400*600800300
MODELSFROG-AFROG-AEFROG-AV
Power supply (V - 50/60 Hz)230 AC230 AC230 AC
Motor power supply (V)230 AC 50/60 Hz230 AC 50/60 Hz230 AC 50/60 Hz
Power (W)460460300
Current draw (mA)1.91.92.5
Working temperature (°C)-20 ÷ +55-20 ÷ +55-20 ÷ +55
Torque (Nm)320320240
Opening time at 90° (s)18189
Cycles/hour1111-
Consecutive cycles33-
Motor thermal protection (°C)150150150
Protection rating (IP)676767
Insulation classIII

Cable Types and Minimum Thicknesses

Cable length (m)up to 20from 20 to 30
Power supply to motor 230 V AC3G x 1.5 mm²3G x 2.5 mm²
Micro limit-switches* no. x 0.5 mm²* no. x 0.5 mm²

*no. = see product mounting instructions. Warning: the cable section is merely indicative as it depends on the motor power and cable length.

When operating at 230 V and outdoors, use H05RN-F-type cables compliant with 60245 IEC 57 (IEC). Indoors, use H05VV-F-type cables compliant with 60227 IEC 53 (IEC). For power supplies up to 48 V, use FROR 20-22 II-type cables compliant with EN 50267-2-1 (CEI).

If cable lengths differ from those specified, establish cable sections based on actual power draw and according to regulation CEI EN 60204-1. For multiple sequential loads, recalculate dimensions based on actual power draw and distances. Refer to accompanying literature for products not covered in this manual.

Installation

The following illustrations are examples; actual space for fitting the operator and accessories varies. Drawings refer to the right-side gearmotor.

Preliminary Operations

Preliminary operations include foundation box installation and release device fastening. Refer to the installation manuals for these products.

Setting up the Gearmotor

Insert the closing limit-switch point adjustment screw into the gearmotor arm.

A: Gearmotor installed on the left

B: Gearmotor installed on the right

Fastening the Gearmotor

Manually open the leaf. Position the gearmotor over the threaded pins of the casing and fasten it.

Lubricate the Transmission Lever

Lubricate the transmission lever. Fit the transmission lever as shown in the drawings.

Establishing the Travel End Points with Mechanical Limit-Switches

Manually open the leaf to the desired point. The leaf maximum opening is 110°.

Unscrew the opening limit-switch point adjustment screw until it touches the foundation box. Tighten the nut to lock the screw into position.

Manually close the gate leaf. Loosen the adjusting screw of the closing limit-switch point until it touches the transmission lever. Tighten the nut to lock the screw into position.

Electrical Connections

Before working on the control panel, cut off the mains power supply and remove batteries, if any. Provide IP67 junction boxes with terminal blocks for connections.

Gear Motor with Encoder

Cables:

  • 1 - Blue cable
  • 2 - Brown cable
  • 3 - Black cable
  • 4 - Yellow-green cable
  • 5 - Green cable
  • 6 - White cable
  • 7 - Earthing braid

Connections:

  • A - Power supply cable
  • B - Encoder cable

Check the correct direction of rotation of the gearmotor and, if necessary, invert the connection of the brown and black cables.

Gearmotor without Encoder

Cables:

  • 1 - Blue cable
  • 2 - Brown cable
  • 3 - Black cable
  • 4 - Yellow-green cable

Check the correct direction of rotation of the gearmotor and, if necessary, invert the connection of the brown and black cables.

Final Operations

Outwards Opening

The following operation differs from standard installation:

Setting up the Gearmotor

Insert the closing limit-switch point adjustment screw into the gearmotor arm.

A: Gearmotor installed on the left

B: Gearmotor installed on the right

Dismantling and Disposal

CAME S.p.A. employs an Environmental Management System certified and compliant with UNI EN ISO 14001 to ensure environmental respect and safeguarding. Please continue safeguarding the environment.

Disposing of the Packaging

Packaging materials (cardboard, plastic, etc.) should be disposed of as solid household waste, separated for recycling. Always comply with local laws before dismantling and disposing of the product. Dispose responsibly!

Disposing of the Product

Products are made of various materials (aluminium, plastic, iron, electrical cables) classified as solid household waste, recyclable by separating them before dumping at authorized city plants. Other components (control boards, batteries, transmitters) may contain hazardous pollutants and must be disposed of by authorized, certified professional services. Always check specific local laws before disposing. Dispose responsibly!

CAME S.p.A.
Via Martiri della Libertà, 15
31030 Dosson di Casier
Treviso - Italy
Tel. (+39) 0422 4940
Fax (+39) 0422 4941
CAME.COM

Declaration of Incorporation Summary

CAME S.p.A. declares that the underground operators for swing gates (FROG-A, FROG-AE, FROG-A1) are compliant with the provisions of Directive 2014/30/UE (Electromagnetic Compatibility) and Directive 2006/42/CE (Machinery Directive), referencing harmonized standards such as EN 61000-6-1, EN 61000-6-3, EN 62233, EN 60335-1, and EN 60335-2-108.

The company commits to providing relevant technical documentation upon justified request from national authorities. The product must not be put into service until the final machine into which it is incorporated has been declared compliant with Directive 2006/42/CE, if applicable.

Models: FROG-A, FROG-AV, FROG-AE, Swing-gate operator

File Info : application/pdf, 12 Pages, 3.75MB

PDF preview unavailable. Download the PDF instead.

FROG-A FROG-AV FROG-AE Acrobat Distiller 19.0 (Windows)

Related Documents

Preview CAME ZLJ24 Control Panel Installation Manual
Comprehensive installation manual for the CAME ZLJ24 control panel, designed for 24V DC swing gate operators. Covers technical features, electrical connections, programming, safety, and troubleshooting.
Preview CAME SDN4-SDN10 Sliding Gate Automation - Installation Manual
Comprehensive installation manual for CAME SDN4, SDN6, SDN8, and SDN10 sliding gate automation systems, covering safety, installation, wiring, programming, and troubleshooting. Includes technical specifications and operational guidance.
Preview CAME BXV Series Sliding Gate Operators Installation Manual
Comprehensive installation manual for CAME BXV series sliding gate operators, detailing product specifications, safety precautions, installation steps, programming functions, error messages, and maintenance procedures.
Preview CAME ATS-P5 Kit - Quick Setup Guide for Swing Gates
Comprehensive quick setup guide for the CAME ATS-P5 Kit, detailing installation, safety, wiring, programming, and accessories for swing gates up to 400kg per leaf and 5m width.
Preview CAME Automatic Sliding Gate Operators Installation Manual
Comprehensive installation and technical manual for CAME automatic sliding gate operators, including models BKS08AGS, BKS12AGS, BKS18AGS, BKS22AGS, BKS18RGS, BKS08ALS, BKS12ALS, BKS18ALS, and BKS22ALS. Covers safety instructions, component descriptions, technical specifications, wiring diagrams, programming functions, and troubleshooting.
Preview CAME ZLX24SA/ZLX24SR Control Panel Installation Manual
Installation manual for CAME ZLX24SA and ZLX24SR control panels, designed for 24V gearmotors in automated gate systems. Provides essential safety guidelines, technical specifications, wiring diagrams, and programming instructions.
Preview CAME ATS30AGS/ATS50AGS/ATS30AGR/ATS50AGR Swing Gate Motor Installation Manual
Comprehensive installation manual for CAME ATS30AGS, ATS50AGS, ATS30AGR, and ATS50AGR swing gate motors. Includes safety instructions, product details, technical specifications, and installation procedures.
Preview CAME ZL60 Control Panel Installation Manual for 24V Gate Gearmotors
This installation manual provides detailed instructions for the CAME ZL60 control panel, designed for 24V gearmotors in automated swing gates for residential and apartment buildings. It covers safety, technical specifications, wiring, and programming.