SUBMITTAL DATA SHEET
High Wall Heat Pump System
Location: [Not Specified]
Engineer: [Not Specified]
Submitted to: [Not Specified]
Submitted by: [Not Specified]
Reference: [Not Specified]
Approval: [Not Specified]
Date: [Not Specified]
Construction: [Not Specified]
Unit #: [Not Specified]
Drawing #: [Not Specified]
Product Overview
This document provides the submittal data sheet for the High Wall Heat Pump System.
Efficiency Ratings
Rating | Cooling | Heating |
---|---|---|
SEER2 | 19.5 | - |
EER2 | 9 | - |
HSPF2-4 | - | 9.3 |
COP | - | 3.25 |
Performance Data
Cooling Performance
Parameter | Value (Btu/hr) |
---|---|
Rated Capacity | 12000 |
Min/Max Capacity | 7400~12100 |
Moisture Removal (L/h) | 1.33 |
Standard Operating Range (°F/°C) | -13~75 (-25~50) |
Conditions | Indoor: 80°F DB/67°F WB Outdoor: 95°F DB/75°F WB |
Heating Performance
Parameter | Value (Btu/hr) |
---|---|
1. @ 47°F Rated | 12000 |
1. @ 47°F Min/Max Capacity | 4300~12700 |
2. @ 17°F Rated | 7400 |
3. @ 5°F Rated: Capacity / COP | 6700 / 2.20 |
3. @ 5°F Max: Capacity | 6700 |
Standard Operating Range (°F/°C) | -13~122 (-25~24) |
1. Conditions | Indoor: 70°F DB/60°F WB Outdoor: 47°F DB/43°F WB |
2. Conditions | Indoor: 70°F DB/60°F WB Outdoor: 17°F DB/15°F WB |
3. Conditions | Indoor: 70°F DB/60°F WB Outdoor: 5°F DB/5°F WB |
Specifications
Indoor Unit Specifications
Parameter | Value |
---|---|
Indoor Air Flow (Turbo/H/M/L/SI) (CFM) | 353.2 / 294.3 / 235.4 / 176.6 / 129.5 |
Indoor Noise Level (Turbo/H/M/L/Si) (dBA) | 44.5/40.0/35.0/25.5/17.5 |
Dimension (W×D×H) | 31.57 x 7.87 x 11.61 inches (802×200×295 mm) |
Package (W×D×H) | 36.02 x 17.95 x 14.17 inches (915×456×360 mm) |
Net/Gross Weight | 24.91/35.71 lbs (11.3/16.2 kg) |
Outdoor Unit Specifications
Parameter | Value |
---|---|
Compressor Type | ROTARY |
Compressor Model | KSK103D33UEZ3 |
Refrigerant | R454B |
Refrigerant Oil Charge (mL) | 310 |
Refrigerant Oil | 5.65 |
Outdoor Air Flow (Max) (CFM) | 1059.5 |
Outdoor Noise Level (dBA) | 54.0 |
Dimension (W×D×H) | 28.35 x 10.63 x 19.49 inches (720×270×495 mm) |
Package (W×D×H) | 32.87 x 10.63 x 21.26 inches (835×270×540 mm) |
Net/Gross Weight | 54.89/67.24 lbs (24.9/30.5 kg) |
Electrical Specifications
Parameter | Value |
---|---|
Power Supply | 115V, 60Hz, 1Ph |
System MCA | 19.5 A |
Connection Wiring | 14#x4 |
System MOCP | 20 A |
Compressor RLA | 14.3 A |
Outdoor Fan Motor RLA | 0.5 A |
Outdoor Fan Motor W | 34 W |
Indoor Fan Motor RLA | 0.6 A |
Indoor Fan Motor W | 20 W |
System Power Input @ Cooling (W) | 1333 (630~1320) W |
System Power Input @ Heating (W) | 1082 (235~1120) W |
MCA: Min. circuit amps (A) | [Value not explicitly listed, but System MCA is 19.5A] |
MOCP: Max. over current protection (A) | [Value not explicitly listed, but System MOCP is 20A] |
RLA: Rated load amps (A) | [Value not explicitly listed, but Compressor RLA is 14.3A] |
W: Fan motor rated output (W) | [Values listed for Indoor and Outdoor Fan Motor W] |
Piping Specifications
Parameter | Value |
---|---|
Throttle type (Indoor) | N/A |
Throttle type (Outdoor) | Capillary |
Liquid Size | 6.35mm (1/4in) |
Gas Size | 9.52mm (3/8in) |
Max. Piping Length (ft/m) | 82 (25) |
Max. Height Difference (ft/m) | 49.20 (15) |
Max. Pre-charged Length (ft/m) | 24.6 (7.5) |
Refrigerant Pre-charged Amount (oz/g) | 21.52 (0.61) |
Additional Charge of Refrigerant (oz/ft) / (g/m) | 0.16 (15) |
Connection Method | Flared |
Unit Dimensions
Indoor Unit Dimensions
Capacity | Body Code | W (inch/mm) | D (inch/mm) | H (inch/mm) |
---|---|---|---|---|
6K~9K | A | 28-3/4in / 729mm | 7-7/8in / 200mm | 11-1/2in / 292mm |
9K~12K | B | 31-5/8in / 802mm | 7-7/8in / 200mm | 11-5/8in / 295mm |
18K | C | 38-1/4in / 971mm | 9in / 228mm | 12-5/8in / 321mm |
18K~24K | D | 42-5/8in / 1082mm | 9-1/4in / 234mm | 13-1/4in / 337mm |
30K~36K | F | 49-5/8in / 1259mm | 11-1/8in / 283mm | 14-1/4in / 362mm |
Outdoor Unit Dimensions
Installation Instructions
Indoor Unit Installation
NOTE: Based on the position of the wall hole relative to the mounting plate, choose the side from which the piping will exit the unit. There are four options for the exit direction of the piping.
NOTE: When the gas side connective pipe is 5/8in (16mm) or more, the wall hole should be 3-1/2in (90mm).
Outdoor Unit Installation Clearance
✔️ Meets all spatial requirements shown in Installation Clearance Requirements above.
Features
- Indoor unit TU1 copper coil
- Humidity control
- 1~100% fan speed setting
- WiFi capability: through WiFi dongle or wired controller with built-in WiFi
- OTA (by using WiFi dongle)
- Multiple control options available:
- Two way communication wired controller: 120N(X6)
- Two way communication wired controller with built-in WiFi: 120N(X6W)
- Infrared wired controller: 120L
- Wireless remote controller
- Third-Party 24V Thermostat*
*24V interface is required.