Blue Ridge High Wall Heat Pump System Submittal Data Sheet

SUBMITTAL DATA SHEET

High Wall Heat Pump System

Location: [Not Specified]

Engineer: [Not Specified]

Submitted to: [Not Specified]

Submitted by: [Not Specified]

Reference: [Not Specified]

Approval: [Not Specified]

Date: [Not Specified]

Construction: [Not Specified]

Unit #: [Not Specified]

Drawing #: [Not Specified]

Product Overview

This document provides the submittal data sheet for the High Wall Heat Pump System.

Image of the indoor unit (white, rectangular with a grille) and the outdoor unit (grey, rectangular with a fan grille). Certifications shown include ARI Certified, ETL LISTED, and Intertek.

Efficiency Ratings

Rating Cooling Heating
SEER2 19.5 -
EER2 9 -
HSPF2-4 - 9.3
COP - 3.25

Performance Data

Cooling Performance

Parameter Value (Btu/hr)
Rated Capacity 12000
Min/Max Capacity 7400~12100
Moisture Removal (L/h) 1.33
Standard Operating Range (°F/°C) -13~75 (-25~50)
Conditions Indoor: 80°F DB/67°F WB
Outdoor: 95°F DB/75°F WB

Heating Performance

Parameter Value (Btu/hr)
1. @ 47°F Rated 12000
1. @ 47°F Min/Max Capacity 4300~12700
2. @ 17°F Rated 7400
3. @ 5°F Rated: Capacity / COP 6700 / 2.20
3. @ 5°F Max: Capacity 6700
Standard Operating Range (°F/°C) -13~122 (-25~24)
1. Conditions Indoor: 70°F DB/60°F WB
Outdoor: 47°F DB/43°F WB
2. Conditions Indoor: 70°F DB/60°F WB
Outdoor: 17°F DB/15°F WB
3. Conditions Indoor: 70°F DB/60°F WB
Outdoor: 5°F DB/5°F WB

Specifications

Indoor Unit Specifications

Parameter Value
Indoor Air Flow (Turbo/H/M/L/SI) (CFM) 353.2 / 294.3 / 235.4 / 176.6 / 129.5
Indoor Noise Level (Turbo/H/M/L/Si) (dBA) 44.5/40.0/35.0/25.5/17.5
Dimension (W×D×H) 31.57 x 7.87 x 11.61 inches (802×200×295 mm)
Package (W×D×H) 36.02 x 17.95 x 14.17 inches (915×456×360 mm)
Net/Gross Weight 24.91/35.71 lbs (11.3/16.2 kg)

Outdoor Unit Specifications

Parameter Value
Compressor Type ROTARY
Compressor Model KSK103D33UEZ3
Refrigerant R454B
Refrigerant Oil Charge (mL) 310
Refrigerant Oil 5.65
Outdoor Air Flow (Max) (CFM) 1059.5
Outdoor Noise Level (dBA) 54.0
Dimension (W×D×H) 28.35 x 10.63 x 19.49 inches (720×270×495 mm)
Package (W×D×H) 32.87 x 10.63 x 21.26 inches (835×270×540 mm)
Net/Gross Weight 54.89/67.24 lbs (24.9/30.5 kg)

Electrical Specifications

Parameter Value
Power Supply 115V, 60Hz, 1Ph
System MCA 19.5 A
Connection Wiring 14#x4
System MOCP 20 A
Compressor RLA 14.3 A
Outdoor Fan Motor RLA 0.5 A
Outdoor Fan Motor W 34 W
Indoor Fan Motor RLA 0.6 A
Indoor Fan Motor W 20 W
System Power Input @ Cooling (W) 1333 (630~1320) W
System Power Input @ Heating (W) 1082 (235~1120) W
MCA: Min. circuit amps (A) [Value not explicitly listed, but System MCA is 19.5A]
MOCP: Max. over current protection (A) [Value not explicitly listed, but System MOCP is 20A]
RLA: Rated load amps (A) [Value not explicitly listed, but Compressor RLA is 14.3A]
W: Fan motor rated output (W) [Values listed for Indoor and Outdoor Fan Motor W]

Piping Specifications

Parameter Value
Throttle type (Indoor) N/A
Throttle type (Outdoor) Capillary
Liquid Size 6.35mm (1/4in)
Gas Size 9.52mm (3/8in)
Max. Piping Length (ft/m) 82 (25)
Max. Height Difference (ft/m) 49.20 (15)
Max. Pre-charged Length (ft/m) 24.6 (7.5)
Refrigerant Pre-charged Amount (oz/g) 21.52 (0.61)
Additional Charge of Refrigerant (oz/ft) / (g/m) 0.16 (15)
Connection Method Flared

Unit Dimensions

Indoor Unit Dimensions

Diagrams showing the indoor unit from the front, side, and top, with dimensions labeled W (width), D (depth), and H (height). A table lists capacities (6K-9K, 9K-12K, 18K, 18K-24K, 30K-36K) with corresponding Body Codes (A, B, C, D, F) and dimensions in inches/mm for Width, Depth, and Height.
Capacity Body Code W (inch/mm) D (inch/mm) H (inch/mm)
6K~9K A 28-3/4in / 729mm 7-7/8in / 200mm 11-1/2in / 292mm
9K~12K B 31-5/8in / 802mm 7-7/8in / 200mm 11-5/8in / 295mm
18K C 38-1/4in / 971mm 9in / 228mm 12-5/8in / 321mm
18K~24K D 42-5/8in / 1082mm 9-1/4in / 234mm 13-1/4in / 337mm
30K~36K F 49-5/8in / 1259mm 11-1/8in / 283mm 14-1/4in / 362mm
Diagram illustrating indoor unit installation location selection. It shows a wall with measurements indicating required clearances: 6 inches (15cm) from the top, 4-3/4 inches (12cm) from the sides, and 70 inches (180cm) horizontally. It also shows the indoor unit's internal structure with potential piping exit points on the left and right sides.
Diagram of the indoor unit's rear view, showing mounting points and dimensions W (width) and H (height), with a circular opening for piping (Φ2.5in/65mm). Notes indicate that when the gas side connective pipe is 5/8in (16mm) or more, the wall hole should be 3-1/2in (90mm).

Outdoor Unit Dimensions

Diagrams showing the outdoor unit from the front, side, and top, with dimensions labeled W, W1, W2, H, and D. Specific measurements are provided in inches and millimeters.

Installation Instructions

Indoor Unit Installation

Diagram illustrating indoor unit installation location selection. It shows a wall with measurements indicating required clearances: 6 inches (15cm) from the top, 4-3/4 inches (12cm) from the sides, and 70 inches (180cm) horizontally. It also shows the indoor unit's internal structure with potential piping exit points on the left and right sides.

NOTE: Based on the position of the wall hole relative to the mounting plate, choose the side from which the piping will exit the unit. There are four options for the exit direction of the piping.

NOTE: When the gas side connective pipe is 5/8in (16mm) or more, the wall hole should be 3-1/2in (90mm).

Outdoor Unit Installation Clearance

Diagram illustrating outdoor unit installation clearance requirements. Arrows indicate minimum clearances: 20 inches (500mm) or more on the front and sides if clear, 14 inches (350mm) or more on the rear, and 4 inches (100mm) or more on the sides. A checkmark symbol indicates that all spatial requirements are met.

✔️ Meets all spatial requirements shown in Installation Clearance Requirements above.

Features

  • Indoor unit TU1 copper coil
  • Humidity control
  • 1~100% fan speed setting
  • WiFi capability: through WiFi dongle or wired controller with built-in WiFi
  • OTA (by using WiFi dongle)
  • Multiple control options available:
    • Two way communication wired controller: 120N(X6)
    • Two way communication wired controller with built-in WiFi: 120N(X6W)
    • Infrared wired controller: 120L
    • Wireless remote controller
    • Third-Party 24V Thermostat*

*24V interface is required.

PDF preview unavailable. Download the PDF instead.

blueridgebds1a12scv-12wmvspecificationssheet 6A1E914D-0837-4E85-AFE3-68BEFAA0E51A Google Sheets

Related Documents

Preview Blue Ridge DS2 High Wall Heat Pump System - Technical Specifications & Features
Detailed submittal data sheet for the Blue Ridge DS2 High Wall Heat Pump System, including efficiency ratings (SEER2, HSPF2-4), performance data, indoor/outdoor unit specifications, electrical requirements, piping details, and features like WiFi connectivity.
Preview Blue Ridge High Wall Heat Pump System: Technical Specifications and Installation Guide
Comprehensive technical specifications, performance data, electrical requirements, and installation guidelines for the Blue Ridge High Wall Heat Pump System, including SEER2, HSPF2-4, and detailed operating conditions.
Preview Blue Ridge XL1 FC Ceiling & Floor Regular System Submittal Data Sheet - Specifications and Features
Detailed submittal data sheet for the Blue Ridge XL1 FC Ceiling & Floor Regular System, including efficiency ratings, performance specifications for cooling and heating, indoor and outdoor unit dimensions, electrical requirements, piping details, and available control features.
Preview Blue Ridge 4-Way Cassette Regular System Submittal Data Sheet
This document provides detailed specifications for the Blue Ridge 4-Way Cassette Regular System, including indoor and outdoor unit dimensions, efficiency ratings, performance data for cooling and heating, electrical specifications, and piping details. It also outlines features and control options.
Preview Ceiling & Floor Heat Pump System Submittal Data Sheet
Submittal data sheet for the Ceiling & Floor Heat Pump System, detailing efficiency, performance, indoor and outdoor specifications, electrical, and piping information. Includes features and installation clearance requirements.
Preview Blue Ridge DS2 High Wall Heat Pump System - Submittal Data Sheet
Detailed submittal data sheet for the Blue Ridge DS2 High Wall Heat Pump System, including specifications for cooling, heating, electrical, piping, dimensions, and installation clearances. Features include humidity control and WiFi capability.
Preview Blue Ridge High Wall Heat Pump System Submittal Data Sheet
Detailed submittal data sheet for the Blue Ridge High Wall Heat Pump System, covering efficiency ratings, performance specifications for cooling and heating, indoor and outdoor unit details, electrical requirements, and piping information.
Preview Blue Ridge High Wall Heat Pump System Submittal Data Sheet
Technical specifications and performance data for the Blue Ridge High Wall Heat Pump System, including efficiency ratings, cooling and heating performance, indoor/outdoor unit details, electrical requirements, and piping specifications.